Hearth and Home Technologies 36, 42 owner manual Secure the Fireplace, Position the Fireplace

Page 13

B. Secure the Fireplace

Position the Fireplace

This fireplace may be placed on either a combustible or noncombustible continuous flat surface. Follow the in- structions for framing in Section 3.D. Slide the fireplace into position. Be sure to provide the minimum air clear- ance at the sides and back of the fireplace assembly. See Section 3.B.

WARNING

Fire Risk!

Prevent contact with sagging, loose insulation.

Do NOT install against vapor barriers or exposed insulation.

Place the Protective Metal Hearth Strips

WARNING

Fire Risk!

Metal hearth strips MUST be installed. Sparks or embers may ignite flooring.

Included with your fireplace you will find two metal hearth strips measuring approximately 26 in. x 4 in. (660 mm x 102 mm). These strips are used to provide added protection where the fireplace and the hearth ex- tension meet.

Slide each metal strip 2 in. (51 mm) under the front edge of the fireplace. The individual pieces must over- lap each other by 1 in. (25 mm) minimum in the middle of the fireplace to provide continuous coverage of the floor. See Figure 4.4. These metal strips should extend from the front and sides of the fireplace opening by 2 in. (51 mm).

Note: When elevating the fireplace above the hearth extension the front of the elevated platform must be protected with a protective metal hearth strip as shown in Figure 4.6.

Level the Fireplace

Level the fireplace side-to-side and front‑to‑back. Shim with noncombustible material, such as sheet metal, as necessary. Secure the fireplace (using the nailing flang- es located on either side of the fireplace) to the vertical framing.

Important: To ensure proper fit of the glass doors, check the fireplace opening for square. Measure diagonal distances of the opening to make sure they are equal. If they are not, continue to shim the fireplace until those diagonals are equal.

1 in. (25 mm) overlap

Protective metal strips are placed 2 in. (51 mm) under the front of the fireplace and must extend beyond the front and sides of fireplace opening by 2 in. (51 mm).

Figure 4.4 Position the Protective Metal Hearth Strips

 

Top piece must overlap

 

bottom piece

 

Raised Platform

2 in.

1 in. (25 mm) min.

(51 mm)

overlap

Floor

2 in.

(51 mm)

Figure 4.5 Protect the Front of an Elevated Platform

Outdoor Lifestyles by Hearth & Home Technologies Inc. • Montana US-CAN4039-156 Rev K • 7/11

13

Image 13
Contents Fire Risk Hot glass will cause burnsSerial Number Grate Listing Label Information/LocationModel Table of Contents Appliance Certification Listing and Code ApprovalsNot intended for use as a primary heat source Getting Started Design and Installation ConsiderationsMoisture Resistance Typical Fireplace SystemInspect Fireplace and Components Tools and Supplies NeededFire Risk Explosion Risk Framing and Clearances Freestanding Installations see FigureSelecting Fireplace Location Exterior Walls see FigureEnclosed Fireplace Clearances to Combustible Materials ClearancesFrame the Fireplace Sidewalls/SurroundsChimney Requirements Install the Dual Cooling Air Kit Installation of FireplaceSharp Edges Asphyxiation Risk Position the Fireplace Secure the FireplaceHeight of Chimney Components Chimney AssemblyChimney Offset/Return Using Offsets/ReturnsAssemble the Chimney Sections Install the Ceiling FirestopsDouble-check the Chimney Assembly Install the Attic Insulation ShieldSecure the Chimney  in./19 mm in lengthChimney Termination Complete the EnclosureMark the Exit Point of the Roof Chase TopST1175/ST475 Square Termination Cap Install the Termination CapTCT1175 Terra Cotta Cap Gas Log/Lighter Provisions AccessoriesGas Code, Ansi Z223.1 Hearth Extension FinishingMantel Finishing MaterialGlass Doors General Information Operating InstructionsClear Space Near the Fireplace Outside AirFlue Damper FirescreenWood Fuel GrateStarting a Fire Diagnostics and Problem Solving TroubleshootingChimney Inspection/Cleaning Maintenance and Servicing the FireplaceDisposal of Ashes Firebox RefractoryWhen cleaning glass door Maintenance Task ListClean Chimney FireReference Materials Fireplace DimensionsDescription Fireplace ComponentsCatalog # Chimney ComponentsAssembled Diameter 17 in./432 mm Height 24 in./610 mm 15-3/4 400 mm 635 x 635 mm 584 x 584 mm 737 x 737 mm Woodburning Termination CapMONTANA-36, MONTANA-36H D. Service PartsMONTANA-42, MONTANA-42H Service PartsThis page intentionally left blank This page intentionally left blank Warranty Coverage This warranty is void if Limited WarrantyRO N a CO ISD D