Hearth and Home Technologies CASTLEWOOD 42 owner manual Finishing, Hearth Extension

Page 22

9Finishing

A. Non-combustible Materials

Materials which will not ignite and burn, composed of any combination of the following:

-

Steel

-

Iron

-

Brick

-

Tile

-

Concrete

-

Slate

-

Glass

-

Plasters

Materials reported as passing ASTM E 136, Standard

Test Method for Behavior of Metals, in a Vertical Tube Furnace at 750° C

B. Combustible Materials

Materials made of or surfaced with any of the following materials:

-

Wood

-

Compressed paper

-

Plant fibers

-

Plastic

Any material that can ignite and burn; flame proofed or not, plastered or un-plastered

C. Hearth Extension

WARNING! Risk of fire! High temperatures, sparks, em- bers or other burning material falling from the fireplace may ignite flooring or concealed combustible surfaces.

Metal hearth strips MUST be installed (Section 7.C.).

Hearth extensions MUST be installed exactly as specified.

Table 12.1

R = 1/k x inches of thickness

Table 12.2

You MUST use a hearth extension with this fireplace.

This fireplace has been tested and approved for use with a hearth extension insulated to a minimum R value of 2.32.

The hearth extension material MUST be covered with tile, stone or other non-combustible material.

Manufactured hearth materials will usually have a published R value (resistance to heat) or k value (conductivity of heat). Refer to the formula in Table 12.1 to convert a k value to an R value,

Refer to Table 12.2 for hearth extension insulation alternatives.

12 in.

 

(305 mm)

 

42 in.

12 in.

(1067 mm)

(305 mm)

 

66 in.

 

(1676 mm)

 

 

Raised Platform

 

20 in. (508 mm) Minimum

 

Flush Hearth

 

30 in. (762 mm) Minimum

Hearth Extension Insulation Alternatives-Total minimum R Value must equal 2.32

 

k per inch

R per inch

 

Material

thick

thick

Minimum thickness required

Hearth & Home HX3, HX4 (Micore 300™)

0.49

2.06

1 in. (25.4 mm)

USG Micore 160™

0.39

2.54

1 in.(25.4 mm)

USG Durock™ Cement Board

1.92

0.52

4 in. (101.6 mm)

 

 

 

 

Cement Mortar

5.0

0.20

10 in. (254 mm)

Common Brick

5.0

0.20

10 in. (254 mm)

 

 

 

 

Ceramic Tile

12.50

0.08

25-3/4 in. (654 mm)

Armstrong™ Privacy Guard Plus

0.46

2.18

1 in. (25.4 mm)

Marble

14.3 to 20.0

0.07 to 0.05

29-1/2 to 41 in. (749.3 to 1041.4 mm)

22

Outdoor Lifestyles by Hearth & Home Technologies Inc. • 4070-300 Rev C • 4/11

Image 22 Contents
Hot glass will cause burns Fire RiskGrate Listing Label Information/LocationNumber Table of Contents Not intended for use as a primary heat source Listing and Code ApprovalsAppliance Certification Do not overfireGetting Started Firescreen Inspect Fireplace and ComponentsGrate Cooling AirSelecting Fireplace Location Freestanding Installations see FigureFraming and Clearances Exterior Walls see FigureFreestanding Installation Clearances Sidewalls/Surrounds Frame the FireplaceChimney Requirements Level the Fireplace Installation of FireplaceSecure the Fireplace Position the Fireplace Place the Protective Metal Hearth StripsInstall Cooling Air Hoods Chimney Assembly Height of Chimney ComponentsAssemble the Chimney Sections Using Offsets/Returns Chase Top Install the Termination CapComplete the Enclosure ST1175/ST475 Square Termination Cap Installing a TCT1175 Square Termination Cap TCT1175 Terra Cotta CapInstallation of Molded Brick Panel Install Side Molded Brick PanelInstall Screens Mortar Optional GrateGas Code, Ansi Z223.1 AccessoriesGas Log/Lighter Provisions Asphyxiation RiskHearth Extension Finishing= 1/k x inches of thickness Framing Material Raised Hearth Extension FramingNon-combustible Equivalent insulationNon-combustible Sealant Flush Hearth Extension FramingFinishing Material Use only non-combustible framing material below standoffsMantel StandoffsOperating Instructions General InformationGlass Doors Clear Space Near the FireplaceFire Risk Smoke Risk Wood Fuel FirewoodStarting a Fire Troubleshooting Diagnostics and Problem SolvingMaintenance and Servicing the Fireplace Disposal of Ashes Chimney Inspection/CleaningClean Maintenance Task ListWhen cleaning glass door Chimney FireFireplace Dimensions Reference MaterialsOptional Components Chimney Components Catalog #330 mm 51 mm Termination caps 15-3/4 400 mmService Parts List ODCASTLEWD-42Traditional Molded Brick Panel At DepotHerringbone Molded Brick Panel Warranty Coverage Limited Warranty This warranty is void ifRO N a CO ISD D