Hearth and Home Technologies CASTLEWOOD 42 owner manual Chimney Components, Catalog #

Page 36

C. Chimney Components

The following pictures show only those chimney components which may be safely used with this fireplace.

Catalog #

 

US

CAN

Description

CAK5A

CAK5A

Chimney Air Kit

n/a

SLA10

Adapter 11 in. (457mm) long

 

 

 

ID4

ID4

Insulated Duct/Outside Air

UD4

UD4

Uninsulated Duct/Outside Air

SL1106

SL406

Chimney Section - 6 in. (152 mm) long

 

 

 

SL1112

SL412

Chimney Section - 12 in. (305 mm) long

SL1118

SL418

Chimney Section - 18 in. (457 mm) long

 

 

 

SL1136

SL436

Chimney Section - 36 in. (914 mm) long

SL1148

SL448

Chimney Section - 48 in. (1219 mm) long

 

 

 

SL11

SL4

Chimney Stabilizer

SL1130

SL430

Chimney Offset/Return - 30 deg

 

 

 

FS538

FS538

Ceiling Firestop - Straight

FS540

FS540

Ceiling Firestop - 30 deg

 

 

Straight Attic Insulation Shield, 24 in. (610

AS10

AS10

mm)

JB577

JB577

Chimney Joint Band

CB576

CB576

Chimney Bracket

RF570

RF570

Roof Flashing - Flat to 6/12 Pitch

RF571

RF571

Roof Flashing - 6/12 to 12/12 Pitch

TR11

TR444

Round Termination Cap

 

 

 

TR11T

TR442

Round Telescoping Termination Cap

TCT1175

 

Terra Cotta Termination Cap

ST1175

ST475

Square Termination Cap

DTO134

DTO134

Short Octagon Decorative Cap

 

 

 

DTO146

DTO146

Tall Octagon Decorative Cap

DTS134

DTS134

Short Square Decorative Cap

 

 

 

DTS146

DTS146

Tall Square Decorative Cap

CT56

CT56

Chase Top

 

 

 

LDS33

LDS33

Decorative Shroud - 3 ft x 3 ft (.91 m x .91 m)

 

 

Decorative Shroud - 4 ft x 6 ft (1.22 m x 1.83

LDS46

LDS46

m)

 

 

Decorative Shroud - 26 in. x 26 in.

LDS-BV

LDS-BV

(660 mm x 660 mm)

 

 

Field Constructed Shrouds (See

 

 

“Woodburning Termination Cap”)

 

 

Adapter-May be used with the following Copper

CT-11A

n/a

Caps

 

n/a

CT-Series

 

 

 

 

n/a

DT-Series

A

13 in.

11 in.(330 mm)

(279 mm)

B

Chimney Sections

 

A

 

 

B

Catalog #

in

 

mm

in

 

mm

SL1106

6

 

152

4-3/4

 

121

SL1112

12

 

305

10-3/4

 

273

 

 

 

 

 

 

 

SL1118

18

 

457

16-3/4

 

425

SL1136

36

 

914

34-3/4

 

883

SL1148

48

 

1219

46-3/4

 

1187

A = Actual Length

B = Effective Length (length of chimney part after it has been snapped to another)

 

Inside

20-3/4 in.

Diameter

(527 mm)

11 in.

 

(279 mm)

Outside Diameter

13 in.

(330 mm)

SL11 Vent Stabilizer

`

36

Outdoor Lifestyles by Hearth & Home Technologies Inc. • 4070-300 Rev C • 4/11

Image 36 Contents
Hot glass will cause burns Fire RiskListing Label Information/Location GrateNumber Table of Contents Listing and Code Approvals Appliance CertificationNot intended for use as a primary heat source Do not overfireGetting Started Inspect Fireplace and Components GrateFirescreen Cooling AirFreestanding Installations see Figure Framing and ClearancesSelecting Fireplace Location Exterior Walls see FigureFreestanding Installation Clearances Sidewalls/Surrounds Frame the FireplaceChimney Requirements Installation of Fireplace Secure the Fireplace Position the FireplaceLevel the Fireplace Place the Protective Metal Hearth StripsInstall Cooling Air Hoods Chimney Assembly Height of Chimney ComponentsAssemble the Chimney Sections Using Offsets/Returns Install the Termination Cap Complete the EnclosureChase Top ST1175/ST475 Square Termination CapInstalling a TCT1175 Square Termination Cap TCT1175 Terra Cotta CapInstallation of Molded Brick Panel Install Side Molded Brick PanelInstall Screens Mortar Optional GrateAccessories Gas Log/Lighter ProvisionsGas Code, Ansi Z223.1 Asphyxiation RiskFinishing Hearth Extension= 1/k x inches of thickness Raised Hearth Extension Framing Non-combustibleFraming Material Equivalent insulationNon-combustible Sealant Flush Hearth Extension FramingFinishing Material Use only non-combustible framing material below standoffsMantel StandoffsOperating Instructions General InformationClear Space Near the Fireplace Glass DoorsFire Risk Smoke Risk Wood Fuel FirewoodStarting a Fire Troubleshooting Diagnostics and Problem Solving Maintenance and Servicing the Fireplace Disposal of Ashes Chimney Inspection/CleaningMaintenance Task List When cleaning glass doorClean Chimney FireFireplace Dimensions Reference MaterialsOptional Components Chimney Components Catalog #330 mm 51 mm Termination caps 15-3/4 400 mmService Parts List ODCASTLEWD-42At Depot Traditional Molded Brick PanelHerringbone Molded Brick Panel Warranty Coverage Limited Warranty This warranty is void ifRO N a CO ISD D