Sunrise Global CE4000, Cable Explorer TDR Module user manual Time & Date

Page 20

Chapter 2

Setup

21

TIME & DATE

The time and date on the CE4000 is set from the System Setup screen (Figure 2-3). The time and date are in the formats hh:mm:ss and mm, dd, yy. Simply use the next field (F1) or the Prev Field (F2) keys to highlight the parameter you would like to change and use the Up/Down arrow keys to increment through the choices. The clock in the CE4000 is set in a 24-hr time format. Press Save to activate your choice and save the parameters to memory.

SERIAL PORT SETTINGS

The serial port speed settings may be set by highlighting them, using the Next Field (F1) or the Prev Field (F2) keys and then choosing the desired value by pressing the Up/Down or Left/ Right arrow keys. Press Save to activate your choice and save the parameter to memory.

Available Serial port speeds (baud rates): 115,200 and 19,200 and 9600.

UNITS

The CE4000 may be set to US measurement units of feet (ft) or to meters (m).

PLOT FILL

The default mode is Disabled. In the default Disabled mode the incidence pulse and reflections are displayed as a simple line graph on the display. When Plot Fill is Enabled, the TDR trace will be filled in under the trace to enhance the viewability.

PLOT 1 COLOR

The color of the main TDR trace may be selected from the list of Magenta, Red, Cyan, Green, Blue, Black and Brown. The default is Magenta.

PLOT 2 COLOR

The color of a second trace, used when comparing traces, may be selected form the list of Magenta, Red, Cyan, Green, Blue, Black and Brown. The default is Blue.

Image 20
Contents CE4000 CE4000 Cable Explorer TDR Disclaimer Contents Maintenance And Service Introduction General Information IntroductionInstrument Overview CM1000 Mainframe and CE4000 Module Mainframe Input/OutputCM1000 mainframe and CE4000 module CE4000 Keyboard Functions History Preparation for USE Unpacking And Initial InspectionGeneral Information Shipment Contents Charging InstructionsSafety Precautions First Time Module Installation CE4000 Cable Explorer TDR Getting Started SetupPower Up To Self Test Screen Main Menu Screen Detail Setup Overview System Setup Detail Time & Date Cable Select Detail Insert Save changes by pressing the Save F3 key Cable Test SET Cable Length Cable Type CE4000 Cable Explorer TDR Measurements Locating Cable FaultsTDR Basics VOP Measurements TDR Trace Loss and Return Loss RTL Trace Signatures TDR Tests with the CE4000 Auto Test Mode Display CE4000 Cable Explorer TDR Zoom Peak Hold Save Manual TDR Measurements Display M1/M2 Pulse Gain / POS Measurements CE4000 Cable Explorer TDR Stored Files CE4000 Cable Explorer TDR Next Adjust Compare Load Performance Specifications and KEY Features Power EnvironmentInterfaces DisplayMaintenance and Service Battery ReplacementCleaning General MaintenanceInternal Rechargeable Battery Troubleshooting Firmware Upgrades CompactFlash Card ReplacementCE4000 Cable Explorer TDR Warranty Technical SupportReturning Equipment to Sunrise Customer’s ResponsibilityMaintenance and Service CE4000 Cable Explorer TDR Appendix Cable Data Additional Cable dataVOP