Sunrise Global Cable Explorer TDR Module, CE4000 user manual Returning Equipment to Sunrise

Page 61

60

CE4000 Cable Explorer TDR

User Manual

RETURNING EQUIPMENT TO SUNRISE

Sunrise manufactures equipment to very high standards. Products are warranted against defects in materials and workmanship, as specified in our published product warranty. When properly used and operated, your equipment will provide many years of service. Should it become necessary to return the, equipment to Sunrise for in or out of warranty repairs or calibration, the following steps should be followed.

Note: If products are repaired or altered by persons not authorized by Sunrise, or not in accordance with instructions furnished by Sunrise or if the products have become defective due to a result of misuse, improper repair, abnormal operating conditions, the labor and materials required to effect the changes will be billed at our standard repair rates.

Customer’s Responsibility

1.Contact Sunrise and request a Returned Material Authorization (RMA) number. Be sure to have your model and serial number ready.

2.After receiving the RMA number, return the equipment with an accurate description of the symptoms and be sure to state the authorization number on your paperwork. The client is responsible for all transportation charges to Sunrise.

3.Original packaging is preferred. If unavailable, carefully package the equipment in alternate packing material to ensure adequate protection during shipping.

Sunrise’s Responsibility

1.Sunrise will acknowledge the receipt of the returned equipment and at that time bring any discrepancies to your attention.

2.Sunrise will replace or repair, at its discretion, any component or sub-assembly it deems necessary to return the unit to a proper condition.

3.After the necessary repairs, Sunrise will perform complete test and re-calibration of the unit.

Image 61
Contents CE4000 CE4000 Cable Explorer TDR Disclaimer Contents Maintenance And Service Introduction Instrument Overview IntroductionGeneral Information Mainframe Input/Output CM1000 Mainframe and CE4000 ModuleCM1000 mainframe and CE4000 module CE4000 Keyboard Functions History Unpacking And Initial Inspection Preparation for USECharging Instructions General Information Shipment ContentsSafety Precautions First Time Module Installation CE4000 Cable Explorer TDR Power Up To Self Test Screen SetupGetting Started Main Menu Screen Detail Setup Overview System Setup Detail Time & Date Cable Select Detail Insert Save changes by pressing the Save F3 key Cable Test SET Cable Length Cable Type CE4000 Cable Explorer TDR TDR Basics Locating Cable FaultsMeasurements VOP Measurements TDR Trace Loss and Return Loss RTL Trace Signatures TDR Tests with the CE4000 Auto Test Mode Display CE4000 Cable Explorer TDR Zoom Peak Hold Save Manual TDR Measurements Display M1/M2 Pulse Gain / POS Measurements CE4000 Cable Explorer TDR Stored Files CE4000 Cable Explorer TDR Next Adjust Compare Load Performance Specifications and KEY Features Environment PowerInterfaces DisplayBattery Replacement Maintenance and ServiceInternal Rechargeable Battery General MaintenanceCleaning Firmware Upgrades CompactFlash Card Replacement TroubleshootingCE4000 Cable Explorer TDR Technical Support WarrantyCustomer’s Responsibility Returning Equipment to SunriseMaintenance and Service CE4000 Cable Explorer TDR Additional Cable data Appendix Cable DataVOP