CONNECTION Natural Gas Grills

Gas Leaks Checks

Before operating your grill, check carefully to be certain that all connections are tight and there are no gas leaks. Never use a match or flame for leak detection. Use soapy water or testing solution. Brush the solution on to connection points and look closely for bubbles indicating escaping gas. If leaks are detected, shut off the main gas supply valve and securely retighten connections, then repeat the leak test.

CAUTION: The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (14” wc).

CAUTION: The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (14” wc).

WARNING: Never use an open flame when testing for gas leaks! Use of an open flame may result in serious bodily injury or death, or in a fire or an explosion causing damage to property.

IMPORTANT

Installation must conform with local codes or, in the absence of local codes, with either the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or CAN/ CGA-B149.1; Natural Gas and Propane Installation Code.

IMPORTANT

When connecting or replacing any gas pipe or fi ttings, all joints must be sealed with leak-proof sealing compound approved for use with natural and propane gases. After making connections, check all joints for leaks using soapy water and a brush.

Breaking in Your Grill

When firing your grill for the first time, it is advisable to run the Main Burner(s) on “HI” for 20 minutes with the hood down and then turn the Main Burners “OFF”. This tempers the grill.

Lighting Your Grill

WARNING: Before each use of your grill it is important to inspect the full length of the gas line hose. If it is evident there is excessive abrasion or wear, or the hose is cut, the hose must be replaced prior to the appliance being put into operation.

DANGER: Make sure that the lid is in the full open postion any time you attempt to light your grill. Failure to open the lid could lead to delayed ignition which may result in serious bodily injury or death, or in a fire or an explosion causing damage to property.

Check your parts list or your authorized dealer for the proper replacement hose assembly. For base cabinet model grills, it will be necessary to go behind your grill to check the hose.

13

Image 13
Contents # 3200 ASSEMBLY, ENSAMBLAJE, Assemblage PGWash hands after handling this product ASSEMBLY, ENSAMBLAJE, Assemblage Brnr Brnr Brnr ASSEMBLY, ENSAMBLAJE, Assemblage ASSEMBLY, ENSAMBLAJE, Assemblage ASSEMBLY, ENSAMBLAJE, Assemblage Brnr Brnr Five-Year Limited Warranty WARRANTY, GARANTÍA, GarantieAssembly Safety InformationLocation of Your Grill LevelingPortable Installation What is Natural Gas?Type of Gas Breaking in Your Grill Gas Leaks ChecksLighting Your Grill Normal Operation Main Burner Snap Ignition Match Lighting Your Grill Main Burners Match Lighting Your Grill Side Burner Side Burner IgnitionFlare Ups Helpful HintsStoring Natural Gas Grills Gas Valve OrificeProblem TroubleshootingMaintenance Inspection and Cleaning of the Spider/Insect Screens Annual MaintenanceMain Burner Flame Pattern Cleaning the Spider/Insect ScreensReplacing the Main Burners Cleaning the Main BurnerEnsamblaje PG Guía DEL Propietario DE LA Parrilla DE GAS NaturalPeligro Peligros Y AdvertenciasUbicación de la barbacoa Información Sobre SeguridadEnsamblaje Nivelación¿Qué es el gas natural? Tipo de gasInstalación portátil Al usar la barbacoa por primera vez Revisión de Fugas de GasEncendido de la barbacoa Operación Normal Hornilla Principal Encender Automáticamente Encender con Fósforos la Hornilla Principal de la Parrilla Encendido con cerillo del quemador lateral de la barbacoa Cómo encender el quemador lateralErupción de Llamas Datos ÚtilesAlmacenaje de barbacoas de gas natural Orificio de la válvula de gasImportante ProblemasMantenimiento Inspección y Limpieza de la Malla Contra Arañas/Insectos Mantenimiento AnualPatrón de la llama del quemador principal Limpieza de las mallas contra arañas e insectosReemplazo de los quemadores principales Limpieza del quemador principalAssemblage PG Guide DE L’UTILISATEUR DU Barbecue AU GAZ NaturelAvertissements Informations Relatives a LA Securite Choix de l’emplacement de votre grillMontage Nivelage du solType de gaz Installation portativeQu’est-ce que le Gaz naturel? Rodage de votre grill Vérifications des fuites de gazAllumage de votre grill Préchauffage du gril Utilisation NormaleOuverture ou fermeture du couvercle pour le grillage Gril de post-chauffageAllumage par étincelle du brûleur principal Allumage par allumette du brûleur principal de votre gril Allumage Du Bruleur Lateral Flammes explosives AstucesStockage des grills à gaz naturel Orifice de la valve de gazGuide DE Depannage Problème Vérification SolutionNettoyage du Couvercle Horaire d’entretien du gril de 90 joursNettoyage de l’acier inoxydable de la grille de cuisson Nettoyage des plaques de distribution de chaleurMaintenance Annuelle Aspect de la flamme du brûleur principal Nettoyage des Grilles anti araignées/insectesNettoyage du brûleur principal Remplacement des brûleurs principauxPage First Name Last Name North Roselle RD. SCHAUMBURG, IL 60195 USA