Weber Q220, Q100 instruction manual GAS Instructions, Attach Propane Cylinder, Check for GAS Leaks

Page 5

GAS INSTRUCTIONS

5

 

 

ATTACH PROPANE CYLINDER

Use propane cylinders with a capacity of 14.1 oz or 16.4 oz. You can find these tanks in the camping, hardware, plumbing section of the store you are shopping at.

CAUTION: Use cylinders that are marked “Propane fuel” only.

Note: Your Weber® gas grill is equipped with a cylinder supply system designed for vapor withdrawal.

While holding carrying handle closest to propane cylinder with one hand, push propane cylinder into regulator and turn clockwise until tight.

DANGER

Do not use an open flame to check for gas leaks. Be sure there are no sparks or open flames in the area while you check for leaks. Sparks or flames will result in a fire or explosion which can cause serious bodily injury or death, and damage to property.

DANGER

Do not store a spare LP-gas cylinder under or near this appliance. Never fill the cylinder beyond 80 percent full. If the instructions are not followed exactly, a fire causing death or serious injury may occur.

CHECK FOR GAS LEAKS

After a period of nonuse, we recommend that you perform the following maintenance procedures for your safety.

Inspect the burner for correct flame pattern. Clean if necessary, following the procedures outlined in the “General Maintenance” section of this manual.

Check all gas fittings for leaks.

WARNING: Do not use a wrench to tighten the connection. Using a wrench could damage the regulator coupling and could cause a leak.

WARNING: You should check for gas leaks every time you disconnect and reconnect a gas fitting.

Note: All factory-made connections have been thoroughly checked for gas leaks. The burners have been flame tested.As a safety precaution however, you should recheck all fittings for leaks before using your Weber® gas grill. Shipping and handling may have loosened or damaged a gas fitting.

WARNING: Perform these leak checks even if your grill was dealer- or store-assembled.

You will need a soap and water solution and a rag or brush to apply it. To perform leak checks make sure the Burner is in the off position and turn on gas supply.

WARNING: Do not ignite burner while leak checking.

Check for leaks by wetting the connections with the soap and water solution and watching for bubbles. If bubbles form, or if a bubble grows, there is a leak. Note: Since some leak test solutions, including soap and water, may be slightly corrosive, all connections should be rinsed with water after checking for leaks.

Check:

1)Regulator-to-propane cylinder connection.

WARNING: If there is a leak at connection (1), remove propane cylinder. Do not operate grill. Use a different propane cylinder and recheck for leaks with soap and water solution. If a leak persists after retightening the propane cylinder, turn OFF the gas. DO NOT OPERATE THE GRILL. Contact the Customer Service Representative in your area using the contact information on our web site. Log onto www.weber.com®.

Check:

2)Valve-to-regulator connections.

WARNING: If there is a leak at connection (2) turn OFF the gas. DO NOT OPERATE THE GRILL.

Contact the Customer Service Representative in your area using the contact information on our web site. Log onto www.weber.com®.

When leak checks are complete, turn gas supply OFF at the source and rinse connections with water.

Image 5
Contents #41061 General Instructions Operating Cooking CleaningStorage AND/OR Nonuse Assembly Instructions DE Montage Instrucciones DE Montaje Parts List Liste DE Vues Éclatée Lista DE PiezasCheck for GAS Leaks GAS InstructionsAttach Propane Cylinder Manual Lighting LightingAnnual Maintenance MAINTENANCE7Main Burner Cleaning Procedure Main Burner Flame PatternReplacing Burner Tube MaintenanceIgnition System Operations Q100 Electronic Ignition System Operations Q120Registre su asador en línea visitando Advertencias Instrucciones GeneralesOperación Almacenamiento O DesusoCocción LimpiezaVerificación DE Fugas DE GAS Conexión DEL Cilindro DE GAS PropanoPeligro Encendido Manual Instrucciones DE OperaciónEncendido Mantenimiento Anual MantenimientoMolde Principal DEL Quemador DE Llama Procedimiento DE Limpieza DEL Quemador PrincipalProtector Contra Arañas E Insectos DE Weber MANTENIMIENTO15Reemplazo DEL Tubo DEL Quemador Operaciones DEL Sistema DE Encendido Q100Guide de L’utilisateur Barbecue au Propane Avertissements Consignes GénéralesEntreposage ET NON-UTILISATION Consignes GénéralesUtilisation CuissonDétection DES Fuites DE GAZ Consignes Pour LE GASFixation DE LA Bouteille DE Propane Allumage Manuel Mode D’EMPLOIAllumage Entretien Annuel Configuration DE Flamme DES Brûleurs PrincipauxProcédure DE Nettoyage DES Brûleurs Principaux Moustiquaires Contre LES Araignées ET LES Moustiques WeberUtilisation DU Systeme D’ALLUMAGE Electronique Q120 Remplacement DE Tube DE BrûleurFonctionnement DU Système D’ALLUMAGE Q100 Troubleshooting Resolución DE Problemas Dépannage Stationary Cart Years Warranty Garantía GarantiePage Page Page Page Page WEBER-STEPHEN Products CO By e-mail / Por correo electrónico / Par e-mail Pour les achats effectués aux États-Unis