Weber E/S-310, E/S-320, EP -310/320 manual

Page 14

14

OPERATING INSTRUCTIONS

 

 

LIGHTING THE SIDE BURNER

DANGER

Failure to open the lid while igniting the side burner, or not waiting 5 minutes to allow the gas to clear if the side burner does not light, may result in an explosive flame-up which can cause serious bodily injury or death.

WARNING: Check hose before each use of barbecue for nicks, cracking, abrasions or cuts. If the hose is found to be damaged in any way, do not use the barbecue. Replace using only Weber® authorized replacement hose. Contact the Customer Service Representative in your area using the contact information on our web site. Log onto www.weber.com®.

1)Open the side burner lid.

2)Check that the side burner valve is turned off (Push control knob in and turn clockwise to ensure that it is in the “OFF” position), turn all burners not being used to the “OFF” position (push in and turn clockwise).

3)Turn the gas supply valve on.

4)Push down and turn the side burner control valve to “HI”.

5)Press the igniter button several times so it clicks each time.

CAUTION: Side burner flame may be difficult to see on a bright sunny day.

WARNING: If the side burner does not light:

a)Turn off the side burner control valve, main burners and gas supply at source.

b)Wait 5 minutes to let the gas clear before you try again, or try lighting with a match (see “Manually Lighting the Side Burner”).

MANUALLY LIGHTING THE SIDE BURNER

DANGER

Failure to open the lid while igniting the side burner, or not waiting 5 minutes to allow the gas to clear if the side burner does not light, may result in an explosive flare-up that can cause serious bodily injury or death.

1)Open the side burner lid.

2)Check that the side burner valve is turned off (Push control knob in and turn clockwise to ensure that it is in the “OFF” position), turn all burners not being used to the “OFF” position (push in and turn clockwise).

3)Turn the gas supply valve on.

4)Put match in a match holder and strike match.

5)Hold match holder and lit match by either side of the side burner.

6)Push down and turn the side burner control valve to “HI”.

CAUTION: Side burner flame may be difficult to see on a bright sunny day.

WARNING: If the side burner does not light:

a)Turn off the side burner control valve, main burners and gas supply at source.

b)Wait 5 minutes to let the gas clear before you try again.

320

 

 

1

 

2

5

2

4

 

 

3

320

 

 

2

1

 

2

6

4 5

 

 

3

WWW.WEBER.COM®

Image 14
Contents GAS Grill 2WARNINGS Liquid Propane GAS Units onlyFor replacement parts call WARRANTY, GARANTÍA, GarantieCustomer Service Center Roselle Road, Suite Schaumburg, IL Para partes de repuesto llame aExploded View E/S/EP Lista DEL Diagrama DE DESPIECE, Liste DE LA Vision Éclatée Exploded View List E/S/EPGenesis320USNG Shroud Storage For Installation in CanadaGeneral Instructions OperatingGeneral Specifications for Piping Install GAS SupplyGAS Instructions Gas Line PipingType of GAS What is Natural GAS?Portable Installation Leak Check PreparationGAS Instructions Operating Instructions LightingMain Burner Manual Lighting Main Burner LightingTo Extinguish Grill illustrated may have Slight differences than320 Problem Check Cure TroubleshootingSideburner Troubleshooting 16MAINTENANCE Turn off the gas supply MAINTENANCE17Replacing Main Burners Crossover Ignition System Operations 18MAINTENANCEReplace Battery if Necessary Barbacoa DE GAS 20ADVERTENCIAS PeligroInstrucciones Generales Especificaciones generales de la tubería Instrucciones Sobre EL GASInstale EL Suministro DE GAS Prueba de las conexionesInstalación Transportable Tipo DE GAS¿QUÉ ES EL GAS NATURAL? Preparativos Para LA Búsqueda DE FugasRevise LA Manguera Flexible a LA Conexión DEL Múltiple Compruebe QUE no Haya Fugas DE GASInstrucciones DE Operación EncendidoEncendido Manual DEL Quemador Principal Encendido DEL Quemador PrincipalPara Apagar Cómo Encender EL Quemador Lateral Encendido Manual DEL Quemador LateralResolución DE Problemas CON EL Quemador Lateral Problema Revisar RemedioMallas Weber Contra Arañas E Insectos MANTENIMIENTO29Mantenimiento DEL Quemador Lateral Mantenimiento AnualProcedimiento Para LA Limpieza DEL Quemador Principal 30MANTENIMIENTOPatrón DE LA Llama DEL Quemador Principal Reemplazo DE LOS Quemadores PrincipalesMANTENIMIENTO31 Reemplace LA Batería SI Fuese NecesarioGrill a GAZ EN Garde Mises EN Garde34GENERALITES Instructions Relatives AU GAZ Installation DE L’ALIMENTATION EN GAZGENERALITES35 QU’EST-CE QUE LE GAZ Naturel ? Installation PortativeType DE GAZ Preparation DE LA Detection DES FuitesDetection DES Fuites DE GAZ Instructions Relatives a L’UTILISATION AllumageAllumage Manuel DU Bruleur Principal Allumage DU Bruleur PrincipalPour Eteindre Allumage DU Bruleur Lateral Allumage Manuel DU Bruleur LateralDepannage DU Bruleur Lateral Probleme Verification SolutionDepannage Maintenance Annuelle MaintenanceMaintenance DU Bruleur Lateral Grilles ANTI-ARAIGNEES/INSECTES WeberRemplacement DES Bruleurs Principaux MAINTENANCE43Procedure DE Nettoyage DU Bruleur Principal Aspect DE LA Flamme DU Bruleur PrincipalRemplacez LA Pile SI Necessaire 44MAINTENANCEOperations DU Systeme D’ALLUMAGE Crossover Page WEBER-STEPHEN Products CO By e-mail / Por correo electrónico / Par e-mail For purchases made in the U.S