Weber EP -310/320 manual GAS Instructions, Install GAS Supply, General Specifications for Piping

Page 9

GENERAL INSTRUCTIONS

9

 

 

Slide out Bottom tray - Remove excess grease, then wash with warm soapy water, then rinse.

Flavorizer® bars and Cooking grates - Clean with a suitable brass bristle brush. As needed, remove from grill and wash with warm soapy water, then rinse with water.

Catch pan - Disposable foil trays are available, or you can line the catch pan with aluminum foil. To clean the catch pan, wash with warm soapy water, then rinse.

Thermometer - Wipe with warm soapy water; clean with plastic scrub ball.

Inside cooking module - Brush any debris off of burner tubes. DO NOT ENLARGE BURNER PORTS (OPENINGS). Wash inside of cooking box with warm soapy water and a water rinse.

Inside Lid - While lid is warm, wipe inside with paper towel to prevent grease build-up. Flaking built-up grease resembles paint fl akes.

Stainless steel surfaces - Wash with a soft cloth and a soap and water solution. Be careful to scrub with the grain direction of the stainless steel.

Do not use cleaners that contain acid, mineral spirits or xylene. Rinse well after cleaning.

Preserve Your Stainless Steel

Your grill or its cabinet, lid, control panel and shelves may be made from stainless steel. To keep the stainless steel looking its best is a simple matter. Clean it with soap and water, rinse with clear water and wipe dry. For stubborn particles, the use of a non- metallic brush can be used.

IMPORTANT: Do not use a wire brush or abrasive cleaners on the stainless steel surfaces of your grill as this will cause scratches.

IMPORTANT: When cleaning surfaces be sure to rub/wipe in the direction of the grain to preserve the look of your stainless steel.

GAS INSTRUCTIONS

INSTALL GAS SUPPLY

General Specifications for Piping

Note: Contact your local municipality for building codes regulating outdoor gas barbecue installations. In absence of Local Codes, you must conform to the latest edition of the National Fuel Gas Code: ANSI Z 223.1/NFPA 54, or CAN/CGA- B149.1, Natural Gas and Propane Installation Code. WE RECOMMEND THAT THIS

INSTALLATION BE DONE BY A PROFESSIONAL.

Some of the following are general requirements taken from the latest edition of the National Fuel Gas Code: ANSI Z 223.1/NFPA 54, or CAN/CGA-B149.1, Natural Gas and Propane Installation Code for complete specifi cations.

DANGER

Do not use an open flame to check for gas leaks. Be sure there are no sparks or open flames in the area while you check for gas leaks. This will result in a fire or explosion which can cause serious bodily injury or death and damage to property.

This barbecue is designed to operate at 7 inches of water column pressure (.2526 psi).

A manual shut-off valve must be installed outdoors, immediately ahead of the quick disconnect.

An additional manual shut-off valve indoors should be installed in the branch fuel line in an accessible location near the supply line.

The quick disconnect connects to a 3/8 inch NPT thread from the gas source. The quick disconnect fi tting is a hand-operated device that automatically shuts off the fl ow of gas from the source when the barbecue is disconnected.

The quick disconnect fi tting can be installed horizontally, or pointing downward. Installing the fi tting with the open end pointing upward can result in collecting water and debris.

The dust covers (supplied plastic plugs) help keep the open ends of the quick disconnect fi tting clean while disconnected.

Pipe compound should be used which is resistant to the action of natural gas when connections are made.

The outdoor connector must be fi rmly attached to rigid, permanent construction.

WARNING: Do not route the 10 foot hose under a deck. The hose must be visible.

Inside wall

Outside wall

This is a typical installation of a Weber® natural gas barbecue. Local codes may require different installations.

Gas supply

Shut off

Locking shut off

Gas Line Piping

If the length of the line required does not exceed 50 feet, use a 5/8" O.D. tube. One size larger should be used for lengths greater than 50 feet.

Gas piping may be copper tubing, type K or L; polyethylene plastic tube, with a minimum wall thickness of .062 inch; or standard weight (schedule 40) steel or wrought iron pipe.

Copper tubing must be tin-lined if the gas contains more than 0.3 grams of hydrogen sulfi de per 100 cubic feet of gas.

Plastic tubing is suitable only for outdoor, underground use.

Gas piping in contact with earth, or any other material which may corrode the piping, must be protected against corrosion in an approved manner.

Underground piping must have a minimum of 18" cover.

Test Connections

All connections and joints must be thoroughly tested for leaks in accordance with local codes and all listed procedures in the latest edition of the National Fuel Gas Code: ANSI Z 223.1/NFPA 54, or CAN/CGA-B149.1

Quick

 

3/ " Pipe

1/ " Pipe

disconnect

8

2

 

 

nipple

 

nipple

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Do Not Use

WWW.WEBER.COM®

Image 9
Contents GAS Grill Liquid Propane GAS Units only 2WARNINGSCustomer Service Center Roselle Road, Suite Schaumburg, IL WARRANTY, GARANTÍA, GarantieFor replacement parts call Para partes de repuesto llame aExploded View E/S/EP Exploded View List E/S/EP Lista DEL Diagrama DE DESPIECE, Liste DE LA Vision ÉclatéeGenesis320USNG Shroud General Instructions For Installation in CanadaStorage OperatingGAS Instructions Install GAS SupplyGeneral Specifications for Piping Gas Line PipingPortable Installation What is Natural GAS?Type of GAS Leak Check PreparationGAS Instructions Lighting Operating InstructionsTo Extinguish Main Burner LightingMain Burner Manual Lighting Grill illustrated may have Slight differences than320 Troubleshooting Sideburner TroubleshootingProblem Check Cure 16MAINTENANCE MAINTENANCE17 Replacing Main BurnersTurn off the gas supply 18MAINTENANCE Replace Battery if NecessaryCrossover Ignition System Operations Barbacoa DE GAS Peligro 20ADVERTENCIASInstrucciones Generales Instale EL Suministro DE GAS Instrucciones Sobre EL GASEspecificaciones generales de la tubería Prueba de las conexiones¿QUÉ ES EL GAS NATURAL? Tipo DE GASInstalación Transportable Preparativos Para LA Búsqueda DE FugasCompruebe QUE no Haya Fugas DE GAS Revise LA Manguera Flexible a LA Conexión DEL MúltipleEncendido Instrucciones DE OperaciónEncendido DEL Quemador Principal Para ApagarEncendido Manual DEL Quemador Principal Encendido Manual DEL Quemador Lateral Cómo Encender EL Quemador LateralProblema Revisar Remedio Resolución DE Problemas CON EL Quemador LateralMantenimiento DEL Quemador Lateral MANTENIMIENTO29Mallas Weber Contra Arañas E Insectos Mantenimiento AnualPatrón DE LA Llama DEL Quemador Principal 30MANTENIMIENTOProcedimiento Para LA Limpieza DEL Quemador Principal Reemplazo DE LOS Quemadores PrincipalesReemplace LA Batería SI Fuese Necesario MANTENIMIENTO31Grill a GAZ Mises EN Garde EN Garde34GENERALITES Installation DE L’ALIMENTATION EN GAZ GENERALITES35Instructions Relatives AU GAZ Type DE GAZ Installation PortativeQU’EST-CE QUE LE GAZ Naturel ? Preparation DE LA Detection DES FuitesDetection DES Fuites DE GAZ Allumage Instructions Relatives a L’UTILISATIONAllumage DU Bruleur Principal Pour EteindreAllumage Manuel DU Bruleur Principal Allumage Manuel DU Bruleur Lateral Allumage DU Bruleur LateralProbleme Verification Solution DepannageDepannage DU Bruleur Lateral Maintenance DU Bruleur Lateral MaintenanceMaintenance Annuelle Grilles ANTI-ARAIGNEES/INSECTES WeberProcedure DE Nettoyage DU Bruleur Principal MAINTENANCE43Remplacement DES Bruleurs Principaux Aspect DE LA Flamme DU Bruleur Principal44MAINTENANCE Operations DU Systeme D’ALLUMAGE CrossoverRemplacez LA Pile SI Necessaire Page WEBER-STEPHEN Products CO By e-mail / Por correo electrónico / Par e-mail For purchases made in the U.S