Weber 3000 Series owner manual Install igniter Check that all burner valves are off

Page 14

Step 10

Step 11

Install igniter

Check that all burner valves are off

Note - The igniter wires are already attached to the Gas Catcher Ignition Chamber and the igniter. This was done to factory test the ignition system.

The igniter lock nut is on the igniter.

Insert the top of the igniter up through the large part of the keyhole in the frame brace. Loosen the igniter lock nut and slide the igniter into the small part of the keyhole. Tighten the igniter lock nut. Figure 11.

Note - If the igniter works loose, carefully tighten the igniter lock nut with an adjustable wrench or pliers.

You will need: one burner control knob.

(Valves are shipped in the OFF position, but you should check to be sure.) Put the knob on each valve. Check by pushing down and turning clockwise. If they do not turn they are off, proceed to the next step. Figure 12.

(a)

Figure 12

 

Step 12

Frame brace

Connect flexible hose to manifold

 

You will need: the 12 foot natural gas supply hose and a

(b)

3/4 inch wrench.

 

Thread fitting end of hose onto manifold. Figure 13 (a).

 

Tighten with wrench.

 

(a)

Figure 11

Keyhole in

Igniter lock nut

frame brace

 

(c)

Frame brace

Small part of

keyhole inFigure 13 frame brace

14

Image 14
Contents Genesis 3000 Series MDANGER MWARNINGS LP GAS Units onlyWarranty Patents and Trademarks Contents General Instructions For Installation in CanadaGas supply testing StorageStep AssemblyCheck package contents BER E W REB Check contents of hardware packs Assemble wheels Assemble frameInsert casters Continue frame assemblyComplete frame assembly Install side burner locks Add cooking boxGas line piping Install gas supplyGeneral Specifications for Piping Test connectionsInstall igniter Check that all burner valves are off Connect flexible hose to manifoldMWARNING Make sure gas supply is OFF Install side burnerInstall manifold bracket MWARNING Do not ignite burners while leak checking Check for gas leaksDeath and damage to property Install Flavorizer Bars and Cooking Grates Install the bottom tray Install the lidSecure side burner MCAUTION Make sure both locks have snapped into placeInstall swing table Complete accessory installation Turn gas supply OFF at the source, then push down LightingTo Extinguish Manual Lighting Lighting the side burner Lighting only the side burner. FigureStorage and/or Nonuse Periodic CleaningCooking Drippings and greaseAnnual Maintenance Inspection and Cleaning of the Weber Spider Stopper GuardsWeber Spider Stopper Guards General MaintenanceMain Burner Cleaning Procedure Main Burner Flame PatternView from behind cooking box Wing nuts Crossover Ignition System Operations Burner does not light, or flame is low in High position Burner flame pattern is erratic. Flame is lowSide Burner Troubleshooting Side Burner Maintenance14-15 17-18,15 21-22 26 27 Parts List Use only Weber factory authorized parts.Page Page Final Word Thanks