Weber 3000 Series Annual Maintenance, Inspection and Cleaning of the Weber Spider Stopper Guards

Page 26

Annual Maintenance

After a period of nonuse we recommend that you perform the following maintenance procedures for your safety.

mWARNING: Check hose before each use of barbecue for nicks, cracking, abrasions or cuts. If the hose is found to be damaged in any way, do not use the barbecue. Replace using only Weber authorized replacement hose. Order from Weber-Stephen Products Co., Customer Service Center or authorized dealer.

Inspect the burners for correct flame pattern. Clean if necessary, following the procedures outlined in the "General Maintenance" section of this manual.

Check all gas fittings for leaks.

mDANGER

Do not use an open flame to check for gas leaks. Be sure there are no sparks or open flames in the area while you check for leaks. This will result in a fire or explosion which can cause serious bodily injury or death, and damage to property.

mWARNING: You should check for gas leaks every time you disconnect and reconnect a gas fitting.

You will need: a soap and water solution and a rag or brush to apply it.

Make sure main burners are in the OFF position.

Make sure side burner is OFF. Remove valve control knob and screws. Remove enamel top.

To perform leak checks: Turn on gas supply.

mWARNING: Do not ignite burners while leak checking.

Check for leaks by wetting the connections with the soap and water solution and watching for bubbles. If bubbles form or if a bubble grows there is a leak.

Note - Since some leak test solutions, including soap and water, may be slightly corrosive, all connections should be rinsed with water after checking for leaks.

Check:

a)Hose to manifold connection. Figure 5 (a).

b)Manifold to side burner hose connection. Figure 5 (b).

mWARNING: If there is a leak at connection a, retighten the fitting with a wrench and recheck for leaks with soap and water solution.

If a leak persists after retightening the fitting, turn OFF the gas. DO NOT OPERATE THE BARBECUE. Contact

Weber-Stephen Customer Service.

c)Side burner hose to side burner connection. Figure 5 (c).

d)Valves to manifold connections. Figure 5 (d).

e)Hose to quick disconnect connection. Figure 5 (e).

mWARNING: If there is a leak at connections

(b), (c), (d) or (e), turn OFF the gas. DO NOT OPERATE

THE BARBECUE. Contact Weber-Stephen Customer Service.

When leak checks are complete, turn gas supply OFF at the source and rinse connections with water.

(a)(b)

(c)

(d)

Figure 5

(e)

Inspection and Cleaning of the Weber Spider Stopper Guards

To inspect the Spider Stopper Guards, remove the control panel and look to see if they have dust or dirt on their outside surfaces. If they do, brush off the outside surface of the Spider Stopper Guards with a soft bristle brush (an old toothbrush for example). Check that there are no gaps in the Spider Stopper Guards’ seams or in the fit around the burners or valves. (See Section "General Maintenance".)

26

Image 26
Contents Genesis 3000 Series MDANGER MWARNINGS LP GAS Units onlyWarranty Patents and Trademarks Contents General Instructions For Installation in CanadaGas supply testing StorageStep AssemblyCheck package contents BER E W REB Check contents of hardware packs Assemble wheels Assemble frameInsert casters Continue frame assemblyComplete frame assembly Install side burner locks Add cooking boxGas line piping Install gas supplyGeneral Specifications for Piping Test connectionsInstall igniter Check that all burner valves are off Connect flexible hose to manifoldMWARNING Make sure gas supply is OFF Install side burnerInstall manifold bracket MWARNING Do not ignite burners while leak checking Check for gas leaksDeath and damage to property Install Flavorizer Bars and Cooking Grates Install the bottom tray Install the lidSecure side burner MCAUTION Make sure both locks have snapped into placeInstall swing table Complete accessory installation Turn gas supply OFF at the source, then push down LightingTo Extinguish Manual Lighting Lighting the side burner Lighting only the side burner. FigureStorage and/or Nonuse Periodic CleaningCooking Drippings and greaseAnnual Maintenance Inspection and Cleaning of the Weber Spider Stopper GuardsWeber Spider Stopper Guards General MaintenanceMain Burner Cleaning Procedure Main Burner Flame PatternView from behind cooking box Wing nuts Crossover Ignition System Operations Burner does not light, or flame is low in High position Burner flame pattern is erratic. Flame is lowSide Burner Troubleshooting Side Burner Maintenance14-15 17-18,15 21-22 26 27 Parts List Use only Weber factory authorized parts.Page Page Final Word Thanks