General Maintenance

Weber Spider Stopper Guards

Your Weber Genesis Gas Barbecue, as well as any outdoor gas appliance, is a target for spiders and other insects. They can nest in the venturi section of the burner tubes. This blocks the normal gas flow, and can cause the gas to flow back out of the air shutter. Figure 6. This could result in a fire in and around the air shutters, under the control panel, causing serious damage to your barbecue.

Venturi

Main Burner Flame Pattern

The Weber Genesis Gas Barbecue burners have been factory set for the correct air and gas mixture. The correct flame pattern is shown in Figure 8.

Burner inside

Tips occasionally yellowish

cooking box

 

Light blue

Dark blue

Flames

Air shutter

Venturi fin

Figure 8

Figure 6

The Weber Spider Stopper Guard is factory installed. It fits tightly around the air shutter section of the burner tube and the valve, thereby preventing spiders and other insects access to the burner tubes through the air shutter openings. Figure 7.

Weber Spider

Stopper Guard

Figure 7

We recommend that you inspect the Weber Spider Stopper Guards at least once a year. (See section “Annual Maintenance”.) Also inspect and clean the Spider Stopper Guards if any of the following symptoms should ever occur.

1.The smell of gas in conjunction with the burner flames appearing yellow and lazy.

2.Barbecue does not reach temperature.

3.Barbecue heats unevenly.

4.One or more of the burners do not ignite.

mDANGER

Failure to correct these symptoms may result in a fire which can cause serious bodily injury or death and cause damage to property.

If the flames do not appear to be uniform the length of the burner tube, follow the burner cleaning procedures.

Main Burner Cleaning Procedure

Turn off the gas supply. Remove the manifold. (See Section “Replacing the main burners”.)

Look inside each burner with a flashlight. Figure 9.

Figure 9

Clean the inside of the burners with a wire (a straightened out coat hanger will work). Figure 10. Check and clean the air shutter opening at the ends of the burners. Check and clean the valve orifices at the base of the valves. Use a brass bristle brush to clean outside of burners. This is to make sure all the burner ports are fully open.

Figure 10

mCAUTION: Do not enlarge the burner ports when cleaning.

Replacing Main Burners

a)Your Weber Gas Barbecue must be OFF and cool.

b)Turn gas OFF at source.

c)Remove control panel: take off the burner control knobs. Remove the screws holding the control panel in place. Lift off the control panel.

27

Image 27
Contents Genesis 3000 Series LP GAS Units only MDANGER MWARNINGSWarranty Patents and Trademarks Contents Storage For Installation in CanadaGas supply testing General InstructionsAssembly Check package contentsStep BER E W REB Check contents of hardware packs Assemble frame Assemble wheelsContinue frame assembly Complete frame assemblyInsert casters Add cooking box Install side burner locksTest connections Install gas supplyGeneral Specifications for Piping Gas line pipingConnect flexible hose to manifold Install igniter Check that all burner valves are offInstall side burner Install manifold bracketMWARNING Make sure gas supply is OFF Check for gas leaks Death and damage to propertyMWARNING Do not ignite burners while leak checking Install Flavorizer Bars and Cooking Grates Install the lid Install the bottom trayMCAUTION Make sure both locks have snapped into place Secure side burnerInstall swing table Complete accessory installation Lighting To ExtinguishTurn gas supply OFF at the source, then push down Manual Lighting Lighting only the side burner. Figure Lighting the side burnerDrippings and grease Periodic CleaningCooking Storage and/or NonuseInspection and Cleaning of the Weber Spider Stopper Guards Annual MaintenanceMain Burner Flame Pattern General MaintenanceMain Burner Cleaning Procedure Weber Spider Stopper GuardsView from behind cooking box Wing nuts Crossover Ignition System Operations Burner flame pattern is erratic. Flame is low Burner does not light, or flame is low in High positionSide Burner Maintenance Side Burner Troubleshooting14-15 17-18,15 21-22 26 27 Use only Weber factory authorized parts. Parts ListPage Page Final Word Thanks