Owner’s Manual - Oxygen Therapy Door

Chapter 2 - Installation and Setup

Unpacking and

Inspection

Parts Included

Installation and

Setup

Tools Required

If the shipping container appears damaged in any way, contact the shipping company immediately. Save all damaged packing materials to assist in proving liability for damage.

Carefully inspect your Oxygen Therapy Door while you unpack it. If damage is noted, or if parts appear to be missing, call SSCI Customer Service at (800) 323-7366.

The following parts are included in the shipment (Figure 1):

„Oxygen Therapy Door

„Ice tray with valve

„Nebulizer with supply tubing

Nebulizer With Supply Tubing

Oxygen Therapy

Door

Ice Tray

With Valve

Figure 1. Parts Included in Shipment

„Phillips screwdriver

„Punch (1/4 in. dia. max.)

„Small hammer or mallet

Form No. 702703 Rev. E August, 2006

7

Image 11
Contents Ssci Page Table of Contents Troubleshooting Repairs and ReplacementsIntroduction About this Manual General InformationModels Oxygen Therapy Door Information Safety NoticesModels Introduction Cleaning Cleansers Care and Cleaning of Stainless SteelCleaning Requirements SafetyTelephone Illinois Ssci Contact Information WarrantyComments Tools Required Installation and SetupUnpacking Inspection Parts Included Installation Setup On a Regal Cage ProcedureHinges Nebulizer Disposition of the Shipping CartonComments Door Seals Operating and CleaningOpening and Closing Latch Adjustment Door and LatchGeneral Ice TrayGauges Changing Between C and F Displays Maximum/Minimum Temperature Humidity RecordingReplacing the Gauge Battery Gauge Battery Slide and Battery Using the NebulizerOxygen Concentration Control Oxygen Concentration ControlIntroduction Cleaning InstructionsNebulizer Cleaning Procedures Replacement Parts Available for the Oxygen Therapy Door Repairs and ReplacementsReplacement Parts General Information Parts Ordering Procedure Tool Required ProceduresCotter Pin Nebulizer Oxygen Supply HoseTools Required Nebulizer Hose Barb FittingRemoval Old-style Gauge Nebulizer Extension Nebulizer Cotter Pin Gauge AssemblyOverview Front View of the New-style Gauge mounted on door Removal New-style GaugeDrilling Button Access Holes Ice Tray Valve Ice TrayRetainer Mounting Screws Retainer and Seal Strip Seal Strip Retainer and Seal StripRefer to Tables 3 and 4 for Part Numbers Parts IdentificationSeal Strip Retainer Part Numbers Door Model Door Dimensions Seal Strip Retainer QuantitySeal Strip Part Numbers Door Model Door Dimensions Seal Strip P/N QuantityGeneral TroubleshootingRMA Numbers Packing and Shipment Returning the Oxygen Therapy Door for RepairsRemedial Action There is no oxygen flow into the cageThere is excessive oxygen leakage from the cage Door does not close or latch correctly One or both of the gauges does not read correctly Inside back cover This page left blank intentionally Toll Free 800 Suburban Surgical Company, IncTwelfth Street Wheeling, IL Phone 847