Suburban Mfg 12155-00-EPEPAA, 12155-00-FNHJAA, 12155-00-FNFNAA manual Oxygen Concentration Control

Page 19

Owner’s Manual - Oxygen Therapy Door

Oxygen

Concentration

Control

4.Set the oxygen flow to 10 liters per minute or higher if more flow is needed.

5.Refer to Oxygen Concentration Control on below to set the desired oxygen concentration.

A simple regulator collar on the nebulizer allows you to control the oxygen percentage concentration in the cage from 28% to 98%. Simply rotate the regulator collar on the nebulizer to the approximate desired percentage (Figure 17). An arrow head molded on the side of the nebulizer neck indicates the selected percentage concentration.

Vent

Regulator

Collar

Arrow Head

Figure 17. Oxygen Concentration Control

As you rotate the regulator collar, the size of the vent opening increases or decreases. The vent opening is larger at low oxygen concentrations to allow a greater amount of ambient air to enter.

Form No. 702703 Rev. E August, 2006

15

Image 19
Contents Ssci Page Table of Contents Troubleshooting Repairs and ReplacementsIntroduction About this Manual General InformationModels Information Safety NoticesModels Oxygen Therapy Door Introduction Cleaning Cleansers Care and Cleaning of Stainless SteelCleaning Requirements SafetyTelephone Illinois Ssci Contact Information WarrantyComments Unpacking Inspection Parts Included Installation Setup Installation and SetupTools Required Hinges ProcedureOn a Regal Cage Nebulizer Disposition of the Shipping CartonComments Door Seals Operating and CleaningOpening and Closing Latch Adjustment Door and LatchGauges Ice TrayGeneral Replacing the Gauge Battery Maximum/Minimum Temperature Humidity RecordingChanging Between C and F Displays Gauge Battery Slide and Battery Using the NebulizerOxygen Concentration Control Oxygen Concentration ControlNebulizer Cleaning Procedures Cleaning InstructionsIntroduction Replacement Parts Repairs and ReplacementsReplacement Parts Available for the Oxygen Therapy Door General Information Parts Ordering Procedure Tool Required ProceduresCotter Pin Nebulizer Oxygen Supply HoseTools Required Nebulizer Hose Barb FittingOverview Nebulizer Extension Nebulizer Cotter Pin Gauge AssemblyRemoval Old-style Gauge Front View of the New-style Gauge mounted on door Removal New-style GaugeDrilling Button Access Holes Ice Tray Valve Ice TrayRetainer Mounting Screws Retainer and Seal Strip Seal Strip Retainer and Seal StripRefer to Tables 3 and 4 for Part Numbers Parts IdentificationSeal Strip Retainer Part Numbers Door Model Door Dimensions Seal Strip Retainer QuantitySeal Strip Part Numbers Door Model Door Dimensions Seal Strip P/N QuantityGeneral TroubleshootingRMA Numbers Packing and Shipment Returning the Oxygen Therapy Door for RepairsRemedial Action There is no oxygen flow into the cageThere is excessive oxygen leakage from the cage Door does not close or latch correctly One or both of the gauges does not read correctly Inside back cover This page left blank intentionally Twelfth Street Wheeling, IL Phone 847 Suburban Surgical Company, IncToll Free 800