Owner’s Manual - Oxygen Therapy Door

Removal - New-style Gauge

1.Open the cage door.

2.With a Phillips screwdriver and a 3/8 in. wrench, remove the two gauge bracket screws/nuts (Figure 24).

3.Remove the gauge bracket and the gauge from the inside of the oxygen door.

Gauge

Bracket

Gauge Bracket Screws

Gauge

Bracket

Figure 24. Front View of the New-style Gauge (mounted on door)

Figure 25. Rear View of the New-style Gauge (removed from door)

Installation of New-style Gauge

1.Order the following from SSCI:

„

New-style Gauge -

P/N 854771

„

Gauge Bracket -

P/N 600162-2

Note: Order a new gauge bracket only if replacing an old-style gauge. If replacing a new-style gauge, use your existing bracket.

2.Loosely mount the gauge bracket (Figure 25) onto the inside of the oxygen door with the screws and nuts removed above. Use the existing gauge bracket mounting holes.

3.Place the gauge into the gauge bracket making sure the gauge is right-side-up.

4.Tighten the bracket screws and nuts to secure the gauge.

5.On the front of the polycarbonate door, mark the centers of the two buttons on the face of the gauge (Figure 12).

Form No. 702703 Rev. E August, 2006

23

Image 27
Contents Ssci Page Table of Contents Troubleshooting Repairs and ReplacementsIntroduction About this Manual General InformationInformation Safety Notices ModelsModels Oxygen Therapy Door Introduction Cleaning Cleansers Care and Cleaning of Stainless SteelCleaning Requirements SafetyTelephone Illinois Ssci Contact Information WarrantyComments Installation and Setup Unpacking Inspection Parts Included Installation SetupTools Required Procedure HingesOn a Regal Cage Nebulizer Disposition of the Shipping CartonComments Door Seals Operating and CleaningOpening and Closing Latch Adjustment Door and LatchIce Tray GaugesGeneral Maximum/Minimum Temperature Humidity Recording Replacing the Gauge BatteryChanging Between C and F Displays Gauge Battery Slide and Battery Using the NebulizerOxygen Concentration Control Oxygen Concentration ControlCleaning Instructions Nebulizer Cleaning ProceduresIntroduction Repairs and Replacements Replacement PartsReplacement Parts Available for the Oxygen Therapy Door General Information Parts Ordering Procedure Tool Required ProceduresCotter Pin Nebulizer Oxygen Supply HoseTools Required Nebulizer Hose Barb FittingNebulizer Extension Nebulizer Cotter Pin Gauge Assembly OverviewRemoval Old-style Gauge Front View of the New-style Gauge mounted on door Removal New-style GaugeDrilling Button Access Holes Ice Tray Valve Ice TrayRetainer Mounting Screws Retainer and Seal Strip Seal Strip Retainer and Seal StripRefer to Tables 3 and 4 for Part Numbers Parts IdentificationSeal Strip Retainer Part Numbers Door Model Door Dimensions Seal Strip Retainer QuantitySeal Strip Part Numbers Door Model Door Dimensions Seal Strip P/N QuantityGeneral TroubleshootingRMA Numbers Packing and Shipment Returning the Oxygen Therapy Door for RepairsRemedial Action There is no oxygen flow into the cageThere is excessive oxygen leakage from the cage Door does not close or latch correctly One or both of the gauges does not read correctly Inside back cover This page left blank intentionally Suburban Surgical Company, Inc Twelfth Street Wheeling, IL Phone 847Toll Free 800