Suburban Mfg 12155-00-DREPAA, 12155-00-FNHJAA manual Disposition of the Shipping Carton, Nebulizer

Page 13

Owner’s Manual - Oxygen Therapy Door

Extension

Cotter Pin

Figure 6. Nebulizer

Disposition of the Shipping Carton

Figure 7. Nebulizer in Place

6.On the nebulizer extension, squeeze the two ends of the cotter pin together and remove the pin from the extension (Figure 6).

7.Open the oxygen therapy door.

8.Place the nebulizer in the ice tray with the extension through the opening in the door (Figures 5, 6, and 7).

9.Inside the door, replace the cotter pin through the extension to hold the nebulizer in place and spread the two cotter pin ends apart to keep the pin from falling out.

10.Attach the free end of the nebulizer plastic tubing to a 50 psi wall oxygen outlet or an oxygen cylinder.

Note: Your oxygen supplier is the best source to make this connection for you.

Installation and setup is complete.

Your SSCI Oxygen Therapy Door is now

ready for use.

The shipping carton can be cut up and thrown away. If adequate space is available, however, it might be handy to retain the carton in case reshipment of the door to the manufacturer ever becomes necessary for repairs.

Form No. 702703 Rev. E August, 2006

9

Image 13
Contents Ssci Page Table of Contents Troubleshooting Repairs and ReplacementsIntroduction About this Manual General InformationModels Information Safety NoticesModels Oxygen Therapy Door Introduction Cleaning Cleansers Care and Cleaning of Stainless SteelCleaning Requirements SafetyTelephone Illinois Ssci Contact Information WarrantyComments Unpacking Inspection Parts Included Installation Setup Installation and SetupTools Required Hinges ProcedureOn a Regal Cage Nebulizer Disposition of the Shipping CartonComments Opening and Closing Latch Adjustment Operating and CleaningDoor and Latch Door SealsGauges Ice TrayGeneral Replacing the Gauge Battery Maximum/Minimum Temperature Humidity RecordingChanging Between C and F Displays Gauge Battery Slide and Battery Using the NebulizerOxygen Concentration Control Oxygen Concentration ControlNebulizer Cleaning Procedures Cleaning InstructionsIntroduction Replacement Parts Repairs and ReplacementsReplacement Parts Available for the Oxygen Therapy Door General Information Parts Ordering Procedure Tool Required ProceduresCotter Pin Nebulizer Oxygen Supply HoseTools Required Nebulizer Hose Barb FittingOverview Nebulizer Extension Nebulizer Cotter Pin Gauge AssemblyRemoval Old-style Gauge Front View of the New-style Gauge mounted on door Removal New-style GaugeDrilling Button Access Holes Ice Tray Valve Ice TrayRefer to Tables 3 and 4 for Part Numbers Seal Strip Retainer and Seal StripParts Identification Retainer Mounting Screws Retainer and Seal StripSeal Strip Retainer Part Numbers Door Model Door Dimensions Seal Strip Retainer QuantitySeal Strip Part Numbers Door Model Door Dimensions Seal Strip P/N QuantityGeneral TroubleshootingRMA Numbers Packing and Shipment Returning the Oxygen Therapy Door for RepairsRemedial Action There is no oxygen flow into the cageThere is excessive oxygen leakage from the cage Door does not close or latch correctly One or both of the gauges does not read correctly Inside back cover This page left blank intentionally Twelfth Street Wheeling, IL Phone 847 Suburban Surgical Company, IncToll Free 800