Chapter 2 - Installation and Setup

Procedure 1.

With a 1/4 in. or smaller punch and a small hammer, remove

 

both hinge pins from the cage door (Figures 2 and 3).

2.

Remove the door from the cage.

Hinges

Hinge Pin

(shown

partially out)

Hinge

Figure 2. Hinges on a Regal Cage

3.

Figure 3. Door Hinge and Hinge Pin

Open the door and, on the rear of the gauge, pull the tape marked “REMOVE TO START” from the battery compartment. The gauge will begin operating.

4.Hang the oxygen therapy door on the existing cage hinges and install the original hinge pins (Figure 4).

5.Hang the ice tray on the button hooks provided on the door (Figures 4 and 5).

Opening

for

Nebulizer

Extension

Ice Tray

Button Hooks

Ice Tray

Figure 4. Oxygen Therapy Door in Place

Figure 5. Ice Tray in Place

on a Regal Cage

 

8

SSCI - Suburban Surgical Company, Inc.

Image 12
Contents Ssci Page Table of Contents Repairs and Replacements TroubleshootingGeneral Information Introduction About this ManualInformation Safety Notices ModelsModels Oxygen Therapy Door Care and Cleaning of Stainless Steel Introduction Cleaning CleansersSafety Cleaning RequirementsSsci Contact Information Warranty Telephone IllinoisComments Installation and Setup Unpacking Inspection Parts Included Installation SetupTools Required Procedure HingesOn a Regal Cage Disposition of the Shipping Carton NebulizerComments Operating and Cleaning Opening and Closing Latch AdjustmentDoor and Latch Door SealsIce Tray GaugesGeneral Maximum/Minimum Temperature Humidity Recording Replacing the Gauge BatteryChanging Between C and F Displays Using the Nebulizer Gauge Battery Slide and BatteryOxygen Concentration Control Oxygen Concentration ControlCleaning Instructions Nebulizer Cleaning ProceduresIntroduction Repairs and Replacements Replacement PartsReplacement Parts Available for the Oxygen Therapy Door General Information Parts Ordering Procedure Procedures Tool RequiredNebulizer Oxygen Supply Hose Cotter PinNebulizer Hose Barb Fitting Tools RequiredNebulizer Extension Nebulizer Cotter Pin Gauge Assembly OverviewRemoval Old-style Gauge Removal New-style Gauge Front View of the New-style Gauge mounted on doorDrilling Button Access Holes Ice Tray Ice Tray ValveSeal Strip Retainer and Seal Strip Refer to Tables 3 and 4 for Part NumbersParts Identification Retainer Mounting Screws Retainer and Seal StripDoor Model Door Dimensions Seal Strip Retainer Quantity Seal Strip Retainer Part NumbersDoor Model Door Dimensions Seal Strip P/N Quantity Seal Strip Part NumbersTroubleshooting GeneralReturning the Oxygen Therapy Door for Repairs RMA Numbers Packing and ShipmentThere is no oxygen flow into the cage Remedial ActionThere is excessive oxygen leakage from the cage Door does not close or latch correctly One or both of the gauges does not read correctly Inside back cover This page left blank intentionally Suburban Surgical Company, Inc Twelfth Street Wheeling, IL Phone 847Toll Free 800