MATERIAL SAFETY DATA SHEET

748377-B

SECTION VI – HEALTH HAZARD DATA

Threshold limit value

NA

Routes of entry

Inhalation, eyes, skin, ingestion

Effects of overexposure

Corrosive to tissue. Inhalation of mist may cause respiratory tract

damage,

 

 

Eyes - Corrosive, immediately flush with water for at least 15 minutes.

 

Call a physician.

 

Skin - Corrosive, remove contaminated clothing. Wash with soap or

 

mild detergent and large amounts of water at least 15 minutes. Call a

Emergency & first aid procedures

physician.

Inhalation - Corrosive, remove to fresh air immediately. Get medical

 

 

attention immediately.

 

Ingestion - Corrosive/toxic, give water or milk immediately and allow

 

vomiting to occur, keeping head below hips to prevent aspiration. Get

 

medical attention immediately.

SECTION VII – SPILL OR LEAK PROCEDURE

Steps to be taken in case material is

Neutralize with dilute acid, take up with sand or other absorbent

released or spilled

material and place in container for disposal.

 

Disposal must be in accordance with standards applicable to

Waste disposal method

generators of hazardous waste, 40CFR262. EPA Hazardous

 

waste number D002.

SECTION VIII – SPECIAL PROTECTION INFORMATION

Respiratory protection

NA

Ventilation

mechanical (general)

Protective gloves

rubber gloves

Eye protection

splash proof or dust-resistant safety goggles with face shield

Other protective equipment

appropriate protective clothing and equipment to prevent

possibility of skin contact. Eye wash fountain, safety shower.

 

SECTION IX – SPECIAL PRECAUTIONS

Precautions to be taken in handling

Store away from incompatible substances.

and storing

 

Other precautions

none

SECTION X – TRANSPORTATION

DOT Hazard Classification 49CFR172.101: Potassium Hydroxide Solution, Class 8, UN1814, Packing Group

II

Exceptions: When transported by Air 49CFR173.154 (b) (1) + (2)

Exceptions: By Motor Vehicle or Rail Car 49CFR173.154 (d) (1)

IATA Hazard Classification 4.2: Potassium Hydroxide Solution, Class 8, UN1814, Packing Group II

Exceptions: 2.8 (Ltd. Qty.)

NOTICE: WHILE ROSEMOUNT ANALYTICAL BELIEVES THE INFORMATION CONTAINED HEREIN IS VALID AND ACCURATE, ROSEMOUNT ANALYTICAL MAKES NO WARRANTY OR REPRESENTATION AS TO ITS VALIDITY, ACCURACY, OR CURRENCY. ROSEMOUNT ANALYTICAL SHALL NOT BE LIABLE OR OTHER- WISE RESPONSIBLE IN ANY WAY FOR USE OF EITHER THIS INFORMATION OR THE MATERIAL TO WHICH IT APPLIES. DISPOSAL OF HAZARDOUS MATERIAL MAY BE SUBJECT TO FEDERAL, STATE, OR LOCAL LAWS AND/OR REGULATIONS.

Sheet 2 of 2

September 2000

Image 76
Contents Model NGA 2000 TO2 Essential Instructions Table of Contents Model NGA 2000 TO2System & Network I/O Module Controls Setup Material Safety Data SheetList of Illustrations Analyzer Module Interconnection with Instrument PlatformModel NGA 2000 TO2 Preface Intended USE Statement DefinitionsSafety Summary Model NGA 2000 TO2 Documentation CompliancesGlossary of Terms Softkeys SystemSection Description and Specifications FeaturesOverview Typical ApplicationsTrace Oxygen Detector Coulometric Principle Trace Oxygen Analyzer Module Top View SPECIFICATIONS1 GeneralSample PhysicalGas Connections Model NGA 2000 TO2 Section Installation UnpackingElectrolyte Electrolyte AdditionGases GAS ConnectionsGAS Overpressure Sample FlowSensor Damage Leak TestElectrical Connections Electrical Shock Hazard Analyzer Module Interconnection with Instrument Platform Outline and Mounting Dimensions Back Panel Connections Operation Displays & Operating KeysMenu Lines & Softkey Functionality Analyzer basic controls calibration & setup…Measure Status… Channel Lock… MFG Data Entering & Changing Variables Signal on mini-bargraphMeasure Back… Ppm O2 Measure Mode DisplayDisplay Status… Main… Channel BasicCal Module Manufacturing Data Displays LCDReset Abort Startup & InitializationInitiate quick start Quick StartMeasure Status… Back… Basic CONTROLS, Setup and Status Power supply voltages… Measure Back…Analyzer Channel Status Display Status… Main… ChannelDisplay Status… Single Component DisplayMain… Channel BasicCal Select Status… Tags Off LCDReset Multi Component DisplayBasic Controls and Setup Range numberOperation Status Range numberDisplay Controls Brightness and ContrastDisplay controls… Brightness 70 %Expert Controls and Setup Analyzer and I/O, expert controls & setup…Analyzer module controls… Measure Channel Back…Calibration Procedure Gas Scale FactorGas scale factor… Air background gas concentrationSpan Calibration Span gas 90.0 ppm Measure Status… Back…Alarms Alarms…Concentration alarm setup… Measure Back… ClrAlm Alarm generation isReRanges Ranges…Begin / end of ranges… Range Begin PpmMeasurement display configuration… Measurement Display ConfigurationLinearization Concentration Measurement Gas measurement unitsConcentration measurement… Gas concentration unitsTemperature compensation at span gas Sensor modelClamp low PVA to Ppm to mg/Nm3 conversion factorFlow measurement… Flow MeasurementFlow lower limit 400 ml/min Temperature measurement… Measure Status… Back… Temperature MeasurementTemperature measurement units System & Network I/O Module CON Trols Setup System & network I/O module controls…37.50 ppm System SIO module…Analog output setup… System SIOAnalog Output Setup Choose signalSelect analog output number Choose the analyzer moduleHold output during calibration Signal value for 0% outputHold output during calibration Outputs value on analyzer failure Operation modeOutput number Analog Output Updates Per Second Type of installed serial inter- faceOutput #1 Yes Baud rate 19200Relay Outputs Setup Invert signalCommunication protocol Choose source moduleChoose signal… System DIOFunction control Input numberSystem Configuration and DIAG- Nostics Load/Save Module Configura- tion Diagnostic MenusAnalyzer Module Diagnostics Date and Time Security CodesSystem reset Measure Back… System ResetEntering a level locked by security code Model NGA 2000 TO2 Overview Electrical Shock Hazard Section Maintenance and ServiceSensor Caustic Liquid Sensor Assembly Refilling SensorSensor Replacement Electrolyte ReplacementSensor Lleak Check Analyzer and I/O expert controls & setup… LinearizationDo not tilt Sensor excessively as elec- trolyte may leak Time & DateLinearization temperature values… Linearization…0000 ppm Linearization raw values sensor current…Flow Sensor Replacement Electronic ComponentsFuses Printed Circuit BoardsSection Troubleshooting TroubleshootingFailure to purge down to ppm levels Erratic and very insensitive readingsModel NGA 2000 TO2 Matrix Section Replacement PartsTO2 NGA 2000 TO2 Trace Oxygen Analyzer Module Replacement Parts Customer Service Section Return of MaterialReturn of Material TrainingModel NGA 2000 TO2 Section Index Model NGA 2000 TO2 Product ELECTROLYTE1 Emergency & first aid procedures Precautions to be taken in handlingOther precautions Threshold limit value Routes of entryRosemount Warranty Asia Pacific EUROPE, Middle EAST, Africa Latin America