Panasonic CU-4KS31NBU service manual

Page 14

Outdoor Unit

CU-4KS31NBU

 

 

 

Indoor Unit

CS-MKS7NKU × 3 + CS-MKS9NKU

 

 

Duct Less Type Rated

 

 

< 230V >

Type

 

 

 

 

4-Room Multi Outdoor Unit

 

 

 

 

 

 

Number of Connectable Indoor Units

 

 

4

 

 

 

 

 

 

Number of Operatable Indoor Units

 

 

4

 

 

 

 

 

 

Voltage Rating

 

 

 

230V Single-Phase 60Hz

 

 

 

 

 

 

 

 

Performance

 

 

 

 

 

 

Cooling

 

 

 

 

 

 

 

Total Capacity

 

 

BTU/h

29,000

( 9,800 to 29,000 )

 

 

 

 

 

 

 

 

kW

8.50

( 2.90 to 8.50 )

 

Sensible Capacity

BTU/h

 

24,400

 

Latent Capacity

BTU/h

 

4,600

 

Air Circulation

(High)

ft3/min (m3/h)

 

1,942 (3,300)

 

Available Voltage Range

V

 

187 to 253

Rating

Running Amperes

A

 

11.4

 

 

 

Power Input

 

 

 

W

 

2,600

Electrical

Power Factor

 

 

%

 

99

Compressor Locked Rotor Amperes

A

 

17.0

 

EER

 

 

 

BTU/h/W

 

11.2

 

SEER

 

 

 

BTU/Wh

 

17.6

 

 

 

 

 

 

 

Fuse or Circuit Breaker Capacity

A

 

20

 

 

 

 

 

 

 

Outdoor Unit

 

 

 

 

 

 

 

 

Control

 

 

 

 

Microprocessor

 

 

 

 

 

 

 

 

Fan Speeds

 

 

 

 

Auto (Hi, Me, Lo)

Features

Compressor

 

 

 

 

DC Twin Rotary (Inverter)

Refrigerant / Amount charged at shipment

Ibs (g)

R410A / 8.38 (3,800)

 

 

Refrigerant Control

 

Electric Expansion Valve

 

Operation Sound (High) Cool

dB-A

 

53

 

Refrigerant Tubing Connections

 

 

Flare Type

 

Max. allowable tubing length per unit

ft (m)

 

100 (30.5)

 

Refrigerant

 

 

Narrow tube

inch (mm)

 

1/4 (6.35) × 4

 

Tube Diameter

 

Wide tube

inch (mm)

3/8 (9.52) × 2 + 1/2 (12.7) × 2

Weight

 

 

 

 

 

 

Outdoor Unit

 

 

 

 

 

 

 

 

Unit Dimensions

inch

35-1/32 × 35-7/16 × 12-19/32

&

Height × Width × Depth

(mm)

(890 × 900 × 320)

Package Dimensions

inch

40-1/8 × 41-11/32 × 16-21/32

Dimensions

Shipping Volume

cu.ft (m3)

 

15.88 (0.45)

 

Height × Width × Depth

(mm)

(1,019 × 1,050 × 423)

 

Weight

 

 

Net

Ibs (kg)

 

174.2 (79.0)

 

 

 

 

Shipping

Ibs (kg)

 

183.0 (83.0)

 

 

 

 

 

 

 

 

DATA SUBJECT TO CHANGE WITHOUT NOTICE.

Remarks:

1.The values shown in performance section and electrical rating section above are based on the following unit combination. For other combination unit, please refer to the "Unit Combination Tables" in this manual.

Indoor Unit : CS-MKE7NKU 3units / CS-MKE9NKU 1units

Outdoor Unit : CU-4KS31NBU 1unit

The combination indoor unit is AHRI 210/240.

 

2.Rating conditions are: Cooling : Indoor air temp. 80 °F DB / 67 °F WB Outdoor air temp. 95 °F DB / 75 °F WB

14

Image 14
Contents DC Inverter MULTI-SYSTEM AIR Conditioner Safety Precautions Prohibit Table of Contents Appendix a Wall Mounted Type Semi-Concealed TypeOperating Range Indoor Unit CS-MKS9NKU × Unit SpecificationsOutdoor Unit CU-3KS19NBU Duct Less Type RatedOutdoor Unit Indoor Unit208V CU-4KS24NBU BTU/h/W Compressor Locked Rotor Amperes 20,600 CU-4KS31NBU Indoor Unit CS-MKS9NKU 4units Outdoor Unit CU-4KS31NBU 1unit 24,200 Major Component Specifications Outdoor UnitOutdoor Unit CU-4KS24NBU Outdoor Unit CU-4KS31NBU Other Component Specifications CU-3KS19NBU CU-4KS24NBU CU-4KS31NBUDimensional Data Unit inchmm 852-0-0010-20500-0 Unit inchmm 852-0-0010-20600-0 Indoor unit Refrigerant Flow DiagramInsulation of Refrigerant Tubing Outdoor unitIndoor unit Outdoor unit 1/4 Strainer Header Sub Main Compressor Accumulator Outdoor Unit CU-3KS19NBU Indoor Unit CS-MKS7NKU × Temperature ChartsTemperature Charts CU-3KS19NBU Outdoor Unit CU-3KS19NBU Indoor Unit CS-MKS9NKU × Cooling Characteristics Outdoor Unit CU-3KS19NBU Indoor Unit CS-MKS12NKU ×Outdoor Unit CU-3KS19NBU Indoor Unit CS-MKS18NKU × Outdoor Unit CU-3KS19NBU Indoor Unit CS-MKS9NB4U × Outdoor Unit CU-3KS19NBU Indoor Unit CS-MKS12NB4U × Outdoor Unit CU-3KS19NBU Indoor Unit CS-KS18NB4UW × Temperature Charts CU-4KS24NBU Outdoor Unit CU-4KS24NBU Indoor Unit CS-MKS7NKU ×Outdoor Unit CU-4KS24NBU Indoor Unit CS-MKS9NKU × Outdoor Unit CU-4KS24NBU Indoor Unit CS-MKS12NKU × Outdoor Unit CU-4KS24NBU Indoor Unit CS-MKS18NKU × Outdoor Unit CU-4KS24NBU Indoor Unit CS-MKS24NKU × Outdoor Unit CU-4KS24NBU Indoor Unit CS-MKS9NB4U × Outdoor Unit CU-4KS24NBU Indoor Unit CS-MKS12NB4U × Outdoor Unit CU-4KS24NBU Indoor Unit CS-KS18NB4UW × Temperature Charts CU-4KS31NBU Outdoor Unit CU-4KS31NBU Indoor Unit CS-MKS9NKU × Outdoor Unit CU-4KS31NBU Indoor Unit CS-MKS12NKU × Outdoor Unit CU-4KS31NBU Indoor Unit CS-MKS18NKU × Outdoor Unit CU-4KS31NBU Indoor Unit CS-MKS24NKU × Outdoor Unit CU-4KS31NBU Indoor Unit CS-MKS9NB4U × Outdoor Unit CU-4KS31NBU Indoor Unit CS-MKS12NB4U × Outdoor Unit CU-4KS31NBU Indoor Unit CS-KS18NB4UW × Cooling Capacity Indoor OutdoorPower Supply 230V Single Phase 60Hz Cooling Capacity CS-MKS12NB4U ×CS-MKS9NKU × CS-KS18NB4UW + CS-MKS12NB4U + CS-MKS12NB4U 30,600 BTU/h CS-MKS9NB4U × Cooling Capacity Low Ambient 15,180 18,570 19,250 25,420 19,410 19,360 24,830 19,520 24,260 30,760 22,560 28,790 22,730 Electric Wiring Diagrams Outdoor Unit CU-3KS19NBU 8FA2-5251-11800-1Outdoor Unit CU-4KS24NBU 8FA2-5251-11600-1 Outdoor Unit CU-4KS31NBU 8FA2-5251-11400-1 Functions Explanation of FunctionsCool Fluctuation fan DRYLow Ambient Cooling Operation Description of function Protective FunctionsCurrent Control Automatic frequency controlCurrent control Compressor Temperature ControlLow Start Current Troubleshooting Before Calling for Service Precautions before Performing Inspection or RepairDisplay of the Error Monitor Lamps Trouble Diagnosis by Error Monitor LampsLocation of the Error Monitor Lamps Checking the outdoor unit Work procedure Check items unit operationChecking the Outdoor System Problems of Each Part and Inspection Points Trouble Diagnosis of Each PartFuse Inspection Points for Each PartOutdoor control circuit board CompressorElectric expansion valve CU-3KS19NBU MV0 MV1 MV2 CU-4KS24NBU MV3 CU-4KS31NBURefrigerant gas pressure Branch tubing temperature sensorBreaker Remedy for symptom 3 to Diagnostic procedureDiagnostic results Trouble Diagnosis of Fan MotorCharacteristics Characteristics of New Refrigerant R410AWhat is New Refrigerant R410A? Components mixing proportionsChecklist before Servicing Tubing Installation Procedures Tools Specifically for R410AProcedure for Replacing Compressor Case of Compressor MalfunctionTo prevent the composition Amount in the charging cylinder is less than 20%Example R410A from changingRecharging Case Refrigerant is LeakingWelding leaking points Retro-Fitting Existing Systems When Tubes are ExtendedCharging Additional Refrigerant Use of Existing Units852-6-4190-581-00-1 Contents For Outdoor UnitPlease Read Before Starting Fins of the outdoor unit. You may get injured ‡ 8VHWKHIODUHPHWKRGIRUFRQQHFWLQJWXELQJGeneral For ceiling-mounted cassette units Installation Site SelectionFor wall-mounted units H1, H2, H3, H4 Connecting indoor unit for CU-4KS24NBU Connecting Indoor UnitsConnecting indoor unit for CU-3KS19NBU 815.88mm Locally purchased Connecting indoor unit for CU-4KS31NBU CS-MKS24NKU Front Baffle Plate for the Outdoor UnitIt is recommended to use baffle plates BackAir Intake Baffle Air Discharge BafflePrecautions for installation CU-4KS24NBU Outer Dimensions of Outdoor UnitCU-3KS19NBU CU-4KS31NBUDiagram of Outdoor Unit Installation Never install only a single indoor unitUse of the Flaring Method Installation ProcessFlaring Procedure with a Flare Tool To 0.5 mm Adjust so that the amount of tube Tubing Connections For wall-mounted units Insulation of Refrigerant TubingTo prevent heat loss and wet floors due to dripping of con  For ceiling-mounted cassette units Air Purging with a Vacuum Pump for Test Run Finishing the InstallationAir Purging External diameter of service port R410A 5/16 Adapter manual, and use the adapter correctly Pump Down What is pump-down?Pump-down procedure If pump-down is not possibleRecommended Wire Length and Diameter Wiring InstructionsGeneral Precautions on Wiring Disconnect switch may be required by national or local codes  For stranded wiring How to connect wiring to the terminalFor Outdoor Unit  For solid core wiring or F-cable For Indoor UnitIndoor unit B Wiring Instructions for the Outdoor UnitIndoor unit D Indoor unit CPerforming a test run Checking tubing and wiringTest Run Connecting a Home Automation Device Installation Check SheetDC1111-0