Panasonic CU-4KS31NBU service manual CS-MKS9NKU ×

Page 52

Outdoor Unit

: CU-4KS24NBU

 

 

 

 

 

 

 

 

 

Indoor Unit

: CS-MKS9NKU × 3

 

 

 

 

 

 

 

 

 

Power Supply : 230V Single Phase 60Hz

 

 

 

 

 

 

 

 

 

< Cooling Capacity >

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RATING CAPACITY:

25,400 BTU/h

 

AIR FLOW RATE:

777 CFM

 

INDOOR

 

 

 

 

 

OUTDOOR

 

 

 

 

 

ENT. TEMP. o F (o C)

 

 

 

AMBIENT TEMP. o F (o C)

 

 

 

WB

 

DB

 

 

65

75

85

 

95

105

115

 

 

 

 

 

 

(18.3)

(23.9)

(29.4)

 

(35.0)

(40.6)

(46.1)

 

 

 

 

 

TC

25,520

24,880

23,960

 

23,340

18,890

14,000

 

 

72

(22.2)

 

SHC

19,410

19,100

18,650

 

18,350

16,240

13,970

 

59

76

(24.4)

 

SHC

21,970

21,670

21,220

 

20,910

18,800

14,000

 

(15.0)

80

(26.7)

 

SHC

24,840

24,530

23,960

 

23,340

18,890

14,000

 

 

84

(28.9)

 

SHC

25,520

24,880

23,960

 

23,340

18,890

14,000

 

 

88

(31.1)

 

SHC

25,520

24,880

23,960

 

23,340

18,890

14,000

 

 

 

 

 

TC

26,760

25,900

24,950

 

24,370

19,290

14,270

 

 

72

(22.2)

 

SHC

16,240

15,940

15,480

 

15,180

13,070

10,960

 

63

76

(24.4)

 

SHC

18,950

18,500

18,200

 

17,900

15,630

13,670

 

(17.2)

80

(26.7)

 

SHC

21,820

21,370

20,910

 

20,610

18,500

14,270

 

 

84

(28.9)

 

SHC

24,380

24,080

23,630

 

23,330

19,290

14,270

 

 

88

(31.1)

 

SHC

26,760

25,900

24,950

 

24,370

19,290

14,270

 

 

 

 

 

TC

27,750

26,880

25,910

 

#

25,400

19,630

14,500

 

 

72

(22.2)

 

SHC

13,070

12,620

12,310

 

12,010

9,750

7,940

 

67

76

(24.4)

 

SHC

15,780

15,330

14,880

 

14,730

12,470

10,660

 

(19.4)

80

(26.7)

 

SHC

18,500

18,200

17,750

 

17,600

15,330

13,370

 

 

84

(28.9)

 

SHC

21,220

20,760

20,460

 

20,160

17,900

14,500

 

 

88

(31.1)

 

SHC

23,930

23,480

23,180

 

22,880

19,630

14,500

 

 

 

 

 

TC

28,690

27,810

26,830

 

26,400

19,890

14,670

 

 

72

(22.2)

 

SHC

9,600

9,300

8,840

 

8,690

6,430

4,770

 

71

76

(24.4)

 

SHC

12,310

12,010

11,560

 

11,410

9,150

7,340

 

(21.7)

80

(26.7)

 

SHC

15,030

14,730

14,430

 

14,280

11,860

10,200

 

 

84

(28.9)

 

SHC

17,750

17,440

16,990

 

16,840

14,580

12,920

 

 

88

(31.1)

 

SHC

20,460

20,160

19,710

 

19,560

17,290

14,670

 

 

 

 

 

TC

29,440

28,560

27,580

 

26,850

20,020

14,760

 

75

76

(24.4)

 

SHC

9,000

8,690

8,240

 

8,090

5,830

4,320

 

(23.9)

80

(26.7)

 

SHC

11,710

11,410

11,110

 

10,810

8,690

7,190

 

 

84

(28.9)

 

SHC

14,430

14,130

13,820

 

13,520

11,410

9,750

 

 

88

(31.1)

 

SHC

17,140

16,840

16,390

 

16,240

13,970

12,470

TC : Total Cooling Capacity (BTU/h) SHC : Sensible Heat Capacity (BTU/h)

NOTE

1.Rating conditions (#) : Indoor Unit Entering Air Temp. 80 °F (26.7 °C) DB / 67 °F (19.4 °C) WB

:Outdoor Ambient Temp. 95 °F (35 °C) DB

2.Above data does not take Freeze Prevention Protection during cooling operation into account. For this reason, the value may vary from the actual cooling characteristics.

3.Above data represents the value when the operation frequency of a compressor is fixed.

52

Image 52
Contents DC Inverter MULTI-SYSTEM AIR Conditioner Safety Precautions Prohibit Table of Contents Appendix a Wall Mounted Type Semi-Concealed TypeOperating Range Unit Specifications Outdoor Unit CU-3KS19NBUIndoor Unit CS-MKS9NKU × Duct Less Type RatedOutdoor Unit Indoor Unit208V CU-4KS24NBU BTU/h/W Compressor Locked Rotor Amperes 20,600 CU-4KS31NBU Indoor Unit CS-MKS9NKU 4units Outdoor Unit CU-4KS31NBU 1unit 24,200 Major Component Specifications Outdoor UnitOutdoor Unit CU-4KS24NBU Outdoor Unit CU-4KS31NBU Other Component Specifications CU-3KS19NBU CU-4KS24NBU CU-4KS31NBUDimensional Data Unit inchmm 852-0-0010-20500-0 Unit inchmm 852-0-0010-20600-0 Refrigerant Flow Diagram Insulation of Refrigerant TubingIndoor unit Outdoor unitIndoor unit Outdoor unit 1/4 Strainer Header Sub Main Compressor Accumulator Temperature Charts CU-3KS19NBU Temperature ChartsOutdoor Unit CU-3KS19NBU Indoor Unit CS-MKS7NKU × Outdoor Unit CU-3KS19NBU Indoor Unit CS-MKS9NKU × Cooling Characteristics Outdoor Unit CU-3KS19NBU Indoor Unit CS-MKS12NKU ×Outdoor Unit CU-3KS19NBU Indoor Unit CS-MKS18NKU × Outdoor Unit CU-3KS19NBU Indoor Unit CS-MKS9NB4U × Outdoor Unit CU-3KS19NBU Indoor Unit CS-MKS12NB4U × Outdoor Unit CU-3KS19NBU Indoor Unit CS-KS18NB4UW × Temperature Charts CU-4KS24NBU Outdoor Unit CU-4KS24NBU Indoor Unit CS-MKS7NKU ×Outdoor Unit CU-4KS24NBU Indoor Unit CS-MKS9NKU × Outdoor Unit CU-4KS24NBU Indoor Unit CS-MKS12NKU × Outdoor Unit CU-4KS24NBU Indoor Unit CS-MKS18NKU × Outdoor Unit CU-4KS24NBU Indoor Unit CS-MKS24NKU × Outdoor Unit CU-4KS24NBU Indoor Unit CS-MKS9NB4U × Outdoor Unit CU-4KS24NBU Indoor Unit CS-MKS12NB4U × Outdoor Unit CU-4KS24NBU Indoor Unit CS-KS18NB4UW × Temperature Charts CU-4KS31NBU Outdoor Unit CU-4KS31NBU Indoor Unit CS-MKS9NKU × Outdoor Unit CU-4KS31NBU Indoor Unit CS-MKS12NKU × Outdoor Unit CU-4KS31NBU Indoor Unit CS-MKS18NKU × Outdoor Unit CU-4KS31NBU Indoor Unit CS-MKS24NKU × Outdoor Unit CU-4KS31NBU Indoor Unit CS-MKS9NB4U × Outdoor Unit CU-4KS31NBU Indoor Unit CS-MKS12NB4U × Outdoor Unit CU-4KS31NBU Indoor Unit CS-KS18NB4UW × Cooling Capacity Indoor OutdoorPower Supply 230V Single Phase 60Hz Cooling Capacity CS-MKS12NB4U ×CS-MKS9NKU × CS-KS18NB4UW + CS-MKS12NB4U + CS-MKS12NB4U 30,600 BTU/h CS-MKS9NB4U × Cooling Capacity Low Ambient 15,180 18,570 19,250 25,420 19,410 19,360 24,830 19,520 24,260 30,760 22,560 28,790 22,730 Electric Wiring Diagrams Outdoor Unit CU-3KS19NBU 8FA2-5251-11800-1Outdoor Unit CU-4KS24NBU 8FA2-5251-11600-1 Outdoor Unit CU-4KS31NBU 8FA2-5251-11400-1 Functions Explanation of FunctionsCool Fluctuation fan DRYLow Ambient Cooling Operation Protective Functions Current ControlDescription of function Automatic frequency controlLow Start Current Compressor Temperature ControlCurrent control Troubleshooting Before Calling for Service Precautions before Performing Inspection or RepairLocation of the Error Monitor Lamps Trouble Diagnosis by Error Monitor LampsDisplay of the Error Monitor Lamps Checking the Outdoor System Work procedure Check items unit operationChecking the outdoor unit Problems of Each Part and Inspection Points Trouble Diagnosis of Each PartInspection Points for Each Part Outdoor control circuit boardFuse CompressorElectric expansion valve CU-3KS19NBU MV0 MV1 MV2 CU-4KS24NBU MV3 CU-4KS31NBUBreaker Branch tubing temperature sensorRefrigerant gas pressure Diagnostic procedure Diagnostic resultsRemedy for symptom 3 to Trouble Diagnosis of Fan MotorCharacteristics of New Refrigerant R410A What is New Refrigerant R410A?Characteristics Components mixing proportionsChecklist before Servicing Tubing Installation Procedures Tools Specifically for R410AProcedure for Replacing Compressor Case of Compressor MalfunctionAmount in the charging cylinder is less than 20% ExampleTo prevent the composition R410A from changingWelding leaking points Case Refrigerant is LeakingRecharging When Tubes are Extended Charging Additional RefrigerantRetro-Fitting Existing Systems Use of Existing Units852-6-4190-581-00-1 Contents For Outdoor UnitPlease Read Before Starting Fins of the outdoor unit. You may get injured ‡ 8VHWKHIODUHPHWKRGIRUFRQQHFWLQJWXELQJGeneral For wall-mounted units Installation Site SelectionFor ceiling-mounted cassette units H1, H2, H3, H4 Connecting indoor unit for CU-3KS19NBU Connecting Indoor UnitsConnecting indoor unit for CU-4KS24NBU 815.88mm Locally purchased Connecting indoor unit for CU-4KS31NBU CS-MKS24NKU Baffle Plate for the Outdoor Unit It is recommended to use baffle platesFront BackAir Intake Baffle Air Discharge BafflePrecautions for installation Outer Dimensions of Outdoor Unit CU-3KS19NBUCU-4KS24NBU CU-4KS31NBUDiagram of Outdoor Unit Installation Never install only a single indoor unitFlaring Procedure with a Flare Tool Installation ProcessUse of the Flaring Method To 0.5 mm Adjust so that the amount of tube Tubing ConnectionsInsulation of Refrigerant Tubing To prevent heat loss and wet floors due to dripping of con For wall-mounted units  For ceiling-mounted cassette unitsAir Purging Finishing the Installation Air Purging with a Vacuum Pump for Test Run External diameter of service port R410A 5/16 Adapter manual, and use the adapter correctlyWhat is pump-down? Pump-down procedure Pump Down If pump-down is not possibleGeneral Precautions on Wiring Wiring InstructionsRecommended Wire Length and Diameter Disconnect switch may be required by national or local codes How to connect wiring to the terminal For Outdoor Unit  For solid core wiring or F-cable For stranded wiring For Indoor UnitWiring Instructions for the Outdoor Unit Indoor unit DIndoor unit B Indoor unit CTest Run Checking tubing and wiringPerforming a test run Connecting a Home Automation Device Installation Check SheetDC1111-0