Omega Engineering CYD201 and CYD208 manual Model CYD200-B RJ-11 to DE-9 Adapter Wiring Details

Page 43

OMEGA Model CYD201/CYD208 User’s Manual

5

4

 

3

2

1

9

 

8

 

7

6

DE-9 CONNECTOR

 

 

 

 

 

= NOT

 

 

 

 

 

USED

 

 

 

 

 

 

 

RxD

 

 

Gnd

 

 

 

TxD

1

2

3

4

5

6

RJ-11

RECEPTACLE

Figure 5-7. Model CYD200-B RJ-11 to DE-9 Adapter Wiring Details

Service

5-7

Image 43
Contents M789-038A June Return Requests / Inquiries WarrantyTable of Contents Table of Contents List of Illustrations This Page Intentionally Left Blank Table of Contents General Chapter IntroductionModel CYD201/CYD208 General Description Resolution Model CYD201/CYD208 SpecificationsHandling Cryogenic Storage Dewars LHe and LN2 Safety PrecautionsHandling Liquid Helium and Liquid Nitrogen Electrostatic Discharge Recommended First AidGround The Instrument Safety SummaryIdentifying Esds Components Handling Esds ComponentsDo Not Substitute Parts Or Modify Instrument Safety SymbolsDo Not Operate In An Explosive Atmosphere Keep Away From Live CircuitsInspection and Unpacking Chapter InstallationRepackaging for Shipment Sensor Installation Recommendations Power and Ground RequirementsTwo-Lead Measurement Two-Lead Vs Four-Lead MeasurementsFour-Lead Measurement Sensor Mounting Connecting Leads To The SensorMeasurement Errors Due To AC Noise J1 Input Sensor Input ConnectionsTerminal Description Rack Mounting Sensor Curve DefinitionModel CYD208-DIN Rack Mounting Hole SizesPower UP Errors Initial Power UP SequenceThis Page Intentionally Left Blank Installation Units KEY Chapter OperationAlarm Operation Alarm SetpointScan Mode Model CYD208 Only Setting Dwell Times Model CYD208 OnlyAlarm Fix Function Model CYD208 Only Latched And Unlatched AlarmsSoftcal Compensations SoftCal Calibration Procedure Erasing SoftCal Compensations Verifying SoftCal OperationOperation Serial Interface Connections Chapter Remote OperationSerial Interface J2 Serial I/O Serial I/O RJ-11 Connector Pin DefinitionsSample Basic Program Serial Interface OperationReturned Serial Interface Command SummarySample Quick Basic 4.0 Program InputInput R Returned Nothing Input F0x Returned NothingInput Hxxx.x Returned Nothing Input Lxxx.x Returned NothingEnd Scanning Model CYD208 Only Switch ID and Alarm DataHigh or Low Parameter H = high alarm, L = low alarm Input YCx Returned NothingCurrent channel,sign,sensor reading,units, alarm statusCRLF Sign,sensor reading,units,alarm status CrlfScan Status Model CYD208 Only This Page Intentionally Left Blank Remote Operation Model CYD201 Rear Panel Connections Chapter ServiceModel CYD208 Rear Panel Connections Model CYD208 Rear Panel ConnectionsGeneral Maintenance Error Code TroubleshootingLine Voltage Configuration Fuse ReplacementRecalibration Current Source CalibrationModel CYD201 Model CYD208 Serial Interface Cable and Adapters 2 A/D Converter CalibrationModel CYD200-B RJ-11 to DE-9 Adapter Wiring Details Page Accessories Model Description of Accessory Chapter Options and AccessoriesModel CYD201/CYD208 Wires Lsci P/N Description of Cable Model Description of AccessoryDIN Series CY-7 Model CYD201/CYD208 Sensors Sensor no Description of SensorSeries DT-420 Series DT-450Options and Accessories A1.0 General Appendix a Curve TablesTable A-2. Curve 1 DT-500DI-8A Voltage-Temp. Characteristics Table A-3. Curve 2 DT-500DRC-D Voltage-Temp. Characteristics 6591 18.0 Table A-5. Curve 4 CTI Diode Voltage-Temp. Characteristics Table A-6. Curve 5 DT-500DI-8C Voltage-Temp. Characteristics Table A-7. Curve 6 CY-7 Voltage-Temp. Characteristics 305.0 50689 Page Page PRESSURE/STRAIN TemperatureFlow