A&D UA-1030T About the Pressure Rating Indicator About Memory, Each time Button or the button

Page 10

ABOUT THE PRESSURE RATING INDICATOR™

ABOUT MEMORY

The Pressure Rating Indicator™ is a feature which provides a snapshot of your blood pressure classifi-

JNC7 Classification Indicator

Note: This device stores the last 90 measurements in memory. The device announces the memory

data values as they are displayed.

Press or

 

cation based on your measurements. This will let you quickly know what your blood pressure readings mean. Each segment of the bar indicator corresponds to the Seventh Report of the Joint National Committee (JNC7) on Prevention, Evaluation and Treatment of High Blood Pressure from the National Heart, Lung and Blood Institute - May 2003. For a more detailed look at this blood pressure classification, please refer to “Assessing High Blood Pressure” on page E-22.

Stage 2 Hypertension

Stage 1 Hypertension

Prehypertension

Normal

Example

Hypertension

Stage 2

1.

Press the

or

button. The average of all

 

measurements and the number of data are

 

displayed. (If no data, “0” is displayed.

 

Press the

,

or

START

button to turn the

 

device off.)

 

 

 

 

2.

Each time the

button (or the button

 

to display the data in the reverse order) is

 

pressed, the memory data is displayed as

 

follows.

 

 

 

 

Average systolic

Average diastolic

Average pulse

Average of all the data

Average systolic

Average diastolic

Average pulse

:The indicator displays a segment, based on the current measurement, corresponding to the JNC7 Classification.

NOTE: Due to other risk factors (e.g. diabetes, obesity, smoking, etc.) in addition to your blood pressure measurement, the Pressure Rating Indicator is approximate. Please consult with your physician for interpretation and diagnosis of your blood pressure measurements.

NOTE: Residents outside of the United States (e.g.. Canada and Mexico) should refer to the WHO Classification Table on page E-22 for assessment of their blood pressure measurement.

Average of all AM (morning) measurements taken between 4:00 and 9:59. (In the example, 10 measurements. If no data, “--” is displayed.)

Average of all PM (evening) measurements taken between 18:00 and 1:59. (In the example, 9 measurements. If no data, “--” is displayed.)

Most recent data (See No. 35). Three seconds after the data number display, the measurement data is displayed.

Last data (No.1). Three seconds after the data number display, the measurement data is displayed.

Average of AM data

Average systolic

Average diastolic

Average pulse

Average of PM data

Systolic

Diastolic

Pulse

Most recent data

Systolic

Diastolic

Pulse

Last data (Oldest)

3.After the last data is displayed, press the

button to return the average display of all measurements.

4. Press the START button to turn the device off. After one minute of non-operation, the device will turn off automatically.

E-17

A&D Medical (Toll-Free): 1-888-726-9966

In Canada - Auto Control Medical (Toll-Free): 1-800-461-0991

E-18

Image 10
Contents Models UA-1030T + UA-1030TCN This Monitor is Clinically Validated PrecautionsImportant Information Table of Contents Medical Designed for LifeWhat Display Symbols Mean What Display Symbols MeanHOW UA-1030T Works Monitor ComponentsBefore YOU Start Adjusting the Pressure Adjusting the ClockSelecting the Correct Cuff Size Tips for Blood Pressure Monitoring Tricheck ModeTaking Your Blood Pressure NOW YOU are Ready Follow These Simple StepsTaking Your Blood Pressure Measurement Using Tricheck Press the Start buttonAbout Cuff Inflation Meter What is AN Irregular HeartbeatMeasurement with SET Pressure Measurement with Desired Systolic PressureDisplayed. If no data, 0 is displayed About the Pressure Rating Indicator About MemoryPress Each time Button or the buttonSelecting the Language Connecting the AC Adapter to the MonitorDisconnecting the AC Adapter from the Monitor Turn the unit off by pressing the Start button140-159 About Blood Pressure130-139 160-179 100-109Can Hypertension be CONTROLLED? What is HYPERTENSION?WHY Measure Blood Pressure AT HOME? Keys to Successful MonitoringEstablishing Baseline Measurements TroubleshootingAnimated Operating Instructions Additional Logbook Sheets HOW do I Record MY Blood PRESSURE?Specifications Contact InformationDate SYS/DIA Pulse Pouls Fecha SIS/DIA Pulso Modèles UA-1030T + UA-1030TCN Renseignements Importants CE Tensiomètre EST Approuvé CliniquementMesures DE Sécurité Table DES Matières Déclaration DE ValidationSignification DES Symboles Symboles imprimés sur le boîtier de lappareilFonctionnement DE Lappareil UA-1030T Pièces DU TensiomètreAvant DE Commencer Réglage DE Lhorloge Sélection DU Brassard DE Taille AppropriéeRéglage DE LA Tension Conseils Pour LA Prise DE LA Tension Artérielle Mode TricheckPrendre LA Tension Artérielle Vous Êtes Maintenant Prêt Procéder Comme SuitPrendre LA Tension Artérielle Mesure À Laide DE Tricheck Indicateur DE Gonflage DU Brassard Mesure Avec Tension DéfinieQU’EST-CE QU’UNE Arythmie ? Mesure Avec Tension Systolique DésiréeLindicateur de niveau de pression Pressure Rating Mesures. En cas dabsence de données, « -- » safficheDéconnexion DE L’ADAPTATEUR CA DU Tensiomètre Sélection DE LA LangueConnexion DE L’ADAPTATEUR CA AU Tensiomètre L1 anglais valeur par défaut L2 français L3 espagnolÉvaluation DE Lhypertension Chez L’ADULTE Renseignements Relatifs À LA Tension ArtérielleQU’EST-CE QUE LA Tension Artérielle ? Hypertension de niveauDéfinition DE Lhypertension EST-IL Possible DE Contrôler Lhypertension ?Comment DOIS-JE Inscrire MA Tension Artérielle ? DépannageÉtablissement DE Mesures DE Référence Outils Dassistance Clientèle EN LigneCaractéristiques Techniques CoordonnéesMedical Toll-Free Canada Auto Control Medical Toll-Free Modelos UA-1030T + UA-1030TCN Información Importante Este Monitor Está Clínicamente ValidadoPrecauciones Rápido. Fácil. Preciso ÍndiceSignificado DE LOS Símbolos DE LA Pantalla Símbolos impresos en el estuche del dispositivoCómo Funciona UA-1030T Componentes DEL MonitorAntes DE Comenzar Ajustes DEL Reloj Selección DEL Brazalete DE Tamaño CorrectoAjustes DE LA Presión Consejos Para EL Control DE LA Presión Arterial Modo TricheckMedición DE LA Presión Arterial Ahora Está Listo Siga Estos Simples PasosMedición DE LA Presión Arterial Medición CON Tricheck Acerca DEL Medidor DE Ingreso DE Aire EN EL Brazalete Medición CON Presión DE ReferenciaQUÉ ES UN Latido Irregular DEL Corazón Medición CON Presión Sistólica DeseadaAcerca DEL Indicador DE Clasificacion DE Presión Acerca DE LA MemoriaPara Conectar EL Adaptador DE CA AL Monitor Selección DEL IdiomaPara Desconectar EL Adaptador DE CA DEL Monitor Grado de hipertensión Acerca DE LA Presión ArterialHipertensión en etapa 100-109 Grado de hipertensión¿POR QUÉ Tomarse LA Presión Arterial EN CASA? ¿QUÉ ES LA HIPERTENSIÓN?¿ES Posible Mantener LA Hipertensión Bajo CONTROL? Claves Para UN Control Satisfactorio¿CÓMO Llevo UN Registro DE MI Presión ARTERIAL? Resolución DE ProblemasCómo Establecer Mediciones DE Referencia Asistencia AL Cliente EN LíneaEspecificaciones Información DE ContactoMedical Toll-Free Canada Auto Control Medical Toll-Free United Kingdom Asahi, Kitamoto-shi, Saitama 364-8585 JapanAutomation Parkway, San Jose, California 95131 U.S.A
Related manuals
Manual 2 pages 38.26 Kb

UA-1030TCN, UA-1030T specifications

The A&D UA-1030T is a cutting-edge digital blood pressure monitor that exemplifies user-friendly design and advanced technology. This device has garnered attention for its accuracy and reliability, making it a popular choice among health-conscious individuals and healthcare professionals alike.

One of the standout features of the UA-1030T is its oscillometric measurement method. This technology measures blood pressure by detecting the vibrations in the artery walls, providing precise systolic and diastolic values. The device is equipped with an easy-to-read LCD display, ensuring that users can quickly and effortlessly interpret their readings.

The UA-1030T boasts a memory function capable of storing up to 30 readings. This feature enables users to track their blood pressure over time, allowing them to monitor trends and changes effectively. It is particularly useful for individuals managing hypertension or other cardiovascular health issues. Additionally, the UA-1030T features a date and time stamp for each reading, facilitating easy reference and documentation.

Another notable characteristic is the device's IntelliSense technology, which enables it to automatically inflate and deflate the cuff to the optimal level for accurate measurements. This smart feature removes guesswork, providing a comfortable experience while ensuring accurate readings. Moreover, the UA-1030T comes with an ergonomic arm cuff, designed for ease of use and a comfortable fit on various arm sizes.

The device also includes a hypertension indicator, which alerts users if their blood pressure readings exceed normal thresholds. This can be a crucial feature for those who may not be aware of their blood pressure status, allowing for timely intervention and consultation with healthcare providers.

For users concerned about power efficiency, the UA-1030T operates on four AAA batteries, ensuring long-lasting use. It also has an automatic shut-off feature that conserves battery life, making it a practical choice for daily monitoring.

In summary, the A&D UA-1030T is a sophisticated yet user-friendly blood pressure monitor that combines accuracy, advanced technology, and convenience. Its oscillometric measurement method, memory function, IntelliSense technology, and hypertension indicator make it an essential tool for anyone serious about maintaining optimal cardiovascular health. Whether for personal use or professional settings, the UA-1030T stands as a reliable companion in the journey towards better health.