A&D 2 Plus owner manual Antenna Symbol, No-stop time at Minutes remaining

Page 27

Section 2: Diving with the Monitor 3 Air

WARNING: There is an acoustic alarm if no-stop time is less than one minute. In this last minute, the no-stop display shows a flashing 0. In order to prevent a decompression dive, you must ascend immediately.

WARNING: It is unsafe diving practice to “push” the Monitor 3 Air, or any other decompression tool, to its limits. Avoid no-stop times of less than 3 minutes at any given depth.

Cylinder Pressure

Cylinder pressure is displayed in pounds per square inch (psi) in 1 psi increments.

Antenna Symbol

No-stop time at 0

minutes remaining

20

If, during the dive, there is an interruption in the transmission of air data to the Monitor 3 Air for more than 30 seconds, the antenna symbol

will appear, accompanied by an acoustic warning. If sensible data is not received within 40 seconds after the antenna symbol appears, the air pressure reading will be replaced by four dashes, and all air time informa- tion will disappear. The most likely cause of transmission interruption is the position of the computer in

relation to the transmitter. As soon as data is transmit- ted again, the computer will display the cylinder pressure and air time information.

Image 27 A&D 2 Plus owner manual Antenna Symbol, No-stop time at Minutes remaining
Contents Page Copyright Notice Safety Considerations Guidelines for Using the Monitor 3 Air Page Table of Contents Memory Mode Page Introduction What is a Dive ComputerIntroduction Computer Screen Features of the Monitor 3 AirMonitor 3 Air display zones and contact letter designations Transmitter This section Step Attaching the Transmitter to Your RegulatorPairing the Wrist Unit to the Transmitter Preparation Preparation Checking the Battery Power Using the Monitor 3 Air Without the TransmitterThis section Preparation for the Dive Diving with the Monitor 3 Air Current Depth Functions During the DiveMaximum Depth Dive TimeAscent Rate Display Ascent RateNo-Stop Time No-stop time at Minutes remaining Antenna SymbolDigital Air Time Remaining ATR Graphic Air Time Remaining ATRHigh Air Consumption Warning Decompression Stop Information Total Ascent Time SOS ModeSurface Mode Surface mode icon Functions at the SurfaceUpon surfacing Wait-to-fly Recommendations Wait-to-fly TimeSurface Interval Time Desaturation TimeMicrobubble Warning Altitude sectors Diving at AltitudeExceeding the Altitude Limit Altitude dive Summary of Attention Messages and AlarmsLost transmission after 40 seconds Alarms Low computer battery Activating Memory Mode Scrolling through logged dives Downloading the Memory to a PC OverviewMemory Mode Activation From Ready Mode or Surface Mode, touchScrolling through Logged Dives Exiting Memory ModeMemory Mode This section Activation from Ready-Mode Ready ModeMaximum allowable no-stop time at that depth Surface Mode Activation from Surface ModeIncrease Time Decrease Time Planning a Decompression Dive Step Pre-Dive Planning Mode Page Care During the Dive Care Before the DiveCare & Maintenance Replacing the Battery Operating TemperaturePage Operational Performance No-Decompression Model Technical SpecificationsZH-L8 ADT Calculation Model Workload and TemperatureSummary