A&D 2 Plus owner manual Decompression Stop Information

Page 30

Decompression Stop Information

If you exceed the no-stop limits, the Monitor 3 will replace the no-stop time with the deepest (first) decom- pression stop depth (in feet) along with the amount of decompression time (in minutes) at that depth. When a decompression stop has been completed, the next shallower decompression stop is displayed, along with its required stop time. When all decompression stops are completed, the DECO arrow disappears and the NO STOP arrow reappears.

WARNING: If you ascend shallower than the required decompression stop depth, the DECO arrow will start flashing and an acoustic alarm will sound. Due to the formation of microbubbles, decompression obligation can increase greatly if a decompression stop is ignored. When the surface is reached during the decompression alarm, the DECO arrow continues to flash to point out the risk of a decompression accident. If you do not descend immediately to the required stop depth, the Monitor 3 will enter SOS Mode. Any decom- pression violation longer than one minute is entered in the computers logbook. Ignoring decompression stops may lead to serious injury or death due to decompression sickness.

Section 2: Diving with the Monitor 3 Air

Decompression

stop information

display

23

Image 30
Contents Page Copyright Notice Safety Considerations Guidelines for Using the Monitor 3 Air Page Table of Contents Memory Mode Page What is a Dive Computer IntroductionIntroduction Features of the Monitor 3 Air Computer ScreenMonitor 3 Air display zones and contact letter designations Transmitter This section Attaching the Transmitter to Your Regulator StepPairing the Wrist Unit to the Transmitter Preparation Preparation Using the Monitor 3 Air Without the Transmitter Checking the Battery PowerThis section Preparation for the Dive Diving with the Monitor 3 Air Functions During the Dive Current DepthDive Time Maximum DepthAscent Rate Ascent Rate DisplayNo-Stop Time Antenna Symbol No-stop time at Minutes remainingGraphic Air Time Remaining ATR Digital Air Time Remaining ATRHigh Air Consumption Warning Decompression Stop Information SOS Mode Total Ascent TimeSurface Mode Surface mode icon Functions at the SurfaceUpon surfacing Wait-to-fly Time Wait-to-fly RecommendationsDesaturation Time Surface Interval TimeMicrobubble Warning Diving at Altitude Altitude sectorsExceeding the Altitude Limit Summary of Attention Messages and Alarms Altitude diveLost transmission after 40 seconds Alarms Low computer battery Activating Memory Mode Scrolling through logged dives Overview Downloading the Memory to a PCMemory Mode From Ready Mode or Surface Mode, touch ActivationExiting Memory Mode Scrolling through Logged DivesMemory Mode This section Ready Mode Activation from Ready-ModeMaximum allowable no-stop time at that depth Activation from Surface Mode Surface ModeIncrease Time Decrease Time Planning a Decompression Dive Step Pre-Dive Planning Mode Page Care Before the Dive Care During the DiveCare & Maintenance Operating Temperature Replacing the BatteryPage Technical Specifications Operational Performance No-Decompression ModelWorkload and Temperature ZH-L8 ADT Calculation ModelSummary