STEP 3 If you do not want to add any additional surface time, go to step 4. If you do want to add surface

time, touch contacts A & C. If you add too much surface time and want to decrease it, touch contacts A & B.

Increase Time

Decrease Time

Note: Surface interval time increases in 15 minute increments for the first 6 hours, 30 minute increments from 6 to 12 hours, and 1-hour increments after that.

Section 4: Pre-Dive Planning Mode

STEP 4 After adding the desired amount of surface interval time, touch contacts A & D. The word "run" flashes for a few moments, then the Monitor starts scrolling from 50 to 200 feet in 10-foot increments. For each depth the com- puter gives the maximum allowable no-stop time at that depth.

Note: If you want to stay longer than the no-stop time limit, proceed to "Planning a Decompres- sion Dive" on page 46.

45

Image 52
Contents Page Copyright Notice Safety Considerations Guidelines for Using the Monitor 3 Air Page Table of Contents Memory Mode Page What is a Dive Computer IntroductionIntroduction Features of the Monitor 3 Air Computer ScreenMonitor 3 Air display zones and contact letter designations Transmitter This section Attaching the Transmitter to Your Regulator StepPairing the Wrist Unit to the Transmitter Preparation Preparation Using the Monitor 3 Air Without the Transmitter Checking the Battery PowerThis section Preparation for the Dive Diving with the Monitor 3 Air Functions During the Dive Current DepthDive Time Maximum DepthAscent Rate Ascent Rate DisplayNo-Stop Time Antenna Symbol No-stop time at Minutes remainingGraphic Air Time Remaining ATR Digital Air Time Remaining ATRHigh Air Consumption Warning Decompression Stop Information SOS Mode Total Ascent TimeFunctions at the Surface Surface Mode Surface mode iconUpon surfacing Wait-to-fly Time Wait-to-fly RecommendationsDesaturation Time Surface Interval TimeMicrobubble Warning Diving at Altitude Altitude sectorsExceeding the Altitude Limit Summary of Attention Messages and Alarms Altitude diveLost transmission after 40 seconds Alarms Low computer battery Activating Memory Mode Scrolling through logged dives Overview Downloading the Memory to a PCMemory Mode From Ready Mode or Surface Mode, touch ActivationExiting Memory Mode Scrolling through Logged DivesMemory Mode This section Ready Mode Activation from Ready-ModeMaximum allowable no-stop time at that depth Activation from Surface Mode Surface ModeIncrease Time Decrease Time Planning a Decompression Dive Step Pre-Dive Planning Mode Page Care Before the Dive Care During the DiveCare & Maintenance Operating Temperature Replacing the BatteryPage Technical Specifications Operational Performance No-Decompression ModelWorkload and Temperature ZH-L8 ADT Calculation ModelSummary