11. PROGRAMMING PROCEDURES

11.2 PLU DATA SETTING

11.2 PLU DATA SETTING

Normal Mode

 

ESB Limited Spec. Mode

Menu Group: 1

Item No.: 1

Item No.:

1

 

 

 

 

Setting or changing the contents of PLU (PLU#, UPC#, Commodity Name, etc.).

 

 

b

 

 

 

 

 

<MENU>

1

AUTO

Set auto code

ENTER

Is status

1

Set tare limit.

Group 1

CODE

for the UPC#

of initial set

 

Max. 2 lb (US)

 

 

 

Max. 1Kg/2.205 lb (CA)

 

 

 

 

 

#8-2?

 

 

 

 

 

 

0

 

 

ENTER

NEXT

or

PLU

 

SET

NEXT

Enter PLU#

Enter UPC#

ENTER

ENTER

(max. 6 dig.)

(max. 6 dig.)

Enter commodity name. (max. 32 chars.x4 lines)

ENTER

BY COUNT

Is status

1

In what

of initial set

 

mode is PLU

#1-6?

 

used?

0WEIGH or FIX

Enter quantity for that

price. (Max. 2 dig.)

ENTER

Enter unit price.

(max. 4 dig)

ENTER

Is status

1

 

Enter flag of

 

 

 

 

 

Enter shelf life.

of initial set

 

 

unit price.

ENTER

 

 

ENTER

#26-4?

 

 

(Refer to NOTE4)

 

(Max. 3 dig.)

 

 

 

 

0

 

 

 

 

 

Is status

 

1

Enter tare weight.

 

 

 

 

ENTER

 

of initial set

 

 

Max. 2 lb (US)

 

#23-1?

 

 

Max. 1Kg/2.205 lb (CA)

 

 

Is status

1

 

 

Enter PERIOD OF

 

of initial set

ENTER

RELISH (Max. 3 dig.)

#7-8?

 

0

 

 

 

 

2

Is status

 

 

 

of initial set

 

 

 

#8-1?

 

 

Select

0 or 1

 

 

compulsory tare

 

 

 

 

0

Is status

1

of initial set

#1-5?

0

Selection Mode Flag

0:Weight

1:By Count

2:Fix Price

ENTER

Is status

1

of initial set

 

#10-5?

 

0

 

Safe Handing

Instruction

0:Non Print

1:Print

ENTER

CHANGE

Enter current

 

Enter new

PLU

ENTER

 

 

ENTER

PLU#

 

PLU#

 

 

DELETE

Enter

Y

or

N

PLU

ENTER

PLU#

 

 

 

 

 

 

 

Is status

1

Set tare %

 

 

of initial set

 

 

ENTER

 

(Max. 99.9%)

#8-7?

 

 

 

 

 

 

0

 

 

 

 

 

 

(Price

%)

 

Is status

2

Enter discount

 

of initial set

 

price or rate.

ENTER

 

(Price: Max. 5 digit

#12-4?

 

 

 

Rate: Max. 3 digit)

 

 

 

 

0 or 1

 

 

 

 

The setting label is issued.

TEST

b

PROG. <MENU>

Group1

ESC.

Main

<MENU>

(Sorting)

Y

Any key except Y

(Not Sorting)

The memory file is sorted when a memory full error occurs.

Is status

1

 

Enter LOGO #.

 

 

 

 

 

 

 

 

of initial set

 

 

 

(#0 - 26)

 

 

ENTER

#9-4?

 

 

 

 

 

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11-6

Image 32
Contents SL-9000-ESB Series Page Safety Summary Meanings of Each SymbolPrecautions Page Page Table of Contents Password Security Setting Password and Protect MenuCalling Menu by Entering Password Operating ProceduresIntroduction 9 0 0 0 3 0 M E S B U S AccessoriesApplicable Model Specification ScaleOption CassetteCMT/PL-3 I/F Main Power Switch Drawer I/FAppearance CA Type DisplayUS Type QR Type KEY Layout Programming KeyboardProgramming Keyboard Function Name of Key FunctionInserts a space when entering characters Sets a block PLU # using the confirmation label procedureDisplays the preceding PLU data Used to set an auto codeOperation Keyboard and Speed KEY Board Operation Keyboard FunctionPrimary function Secondary function Enters numeric data such as PLU #, unit price and tareSets the quantity of commodity in by Count mode Prints the customer labelDisplays the date Selects the item for change Print/OFFIssues a test label Adjusts the zero pointIssue. Optional key by initial setting Calls the PLU frequently usedSpeed KEY SET Procedure Before OperationNutrition Setting Installation Procedure Remote DisplayInstallation Procedure Level Adjustment Removal and Replacement of Media Removal and Replacement of Media Outline of Operation Menu selectionHow to Select Menu and Item No Programming ProceduresHow to access the Programming Menu ESB Limited Specification Enter the PasswordTitle and Contents of Programming Menu 2nd line TEL How to enter charactersTEC Store Unit Price Change MenuGroup MainPLU Data Setting MenuPreset Tare T1.000Quantity PLU#Open PLU Open PLU Data PLU#DEPT# Ingredient Message Group MainNutrition Facts Additional Information Area 2~6 ~99999 or 0.0~999.9 Daily Value Max digits Contents of daily value Set the Daily Value TableMemory file sort Memory file is sorted when a memory full error occursDeleting Nutrition Data PLU Verifying Label GroupAddress Setting Special Information Grade LineSpeed KEY Setting Setting Department/Vendor NumberDepartment Number Vendor NumberPrint Format By pressing KeyLabel Format Number Table 22/38POS DATE/TIME Setting Normal Mode ESB Limited Spec. Mode Menu Group Item NoError code during PL-3 operation PL-3 OperationSave Key of the PL-3, then check whether the Save LED is onClear Transmission Item ListOperable Inoperable Transmission Delay Time Table ON-LINE/LOCALUPC # BAR Code FormatExample UPC# PC/D Flag PLU # UPC# PC/D Price WeightC C C C Enter the title # See Note Enter the title. See NoteTitle No Format Additional 221 Additional 231 232Transferring Logo Data Error message during data transmissionTime OUT Error Deleting a vendor number Idiom SettingVendor Setting Enter Free FormatKey functions 11-31 C D B aAvailable format and print items for free format For PRTPassword Security Setting Password and Protect Menu13-2 Calling Menu by Entering Password REGOperating Procedures How to access the REG., M.DOWN, or Rewrap menuWeighing Operation Sample labelFIX Price Operation for US Type only By Count Operation Sample label for US type Sample label for CA and QR type14-5 Print Count Operation Example B When operating in Fix or By Count mode From the platter Labels are being issuedPLU Pre=1Issuing Labels with NET Weight Statement for US Type only For14-10 TARE/SAVE Function Procedures Remove the commodity Together with the containerWeight Unit Price Calling and Printing Grade LinesCalling and Printing Logos Or CSelecting Print Item and Adjusting the LCD Brightness Menu REG, M.DOWN, or Rewrap Mode WEIGH, FIX, or by CountPRT Date ChangeFeed Batch Print Mode with 30 Items Run Assignment Changing a Unit Price and Calling G.Line/LOGO Void Stopping or Canceling Label IssuePreset Count Floating Vendor Receipt will be issued Price deletionSubtotal Enter vendor #How to access the Read or Reset menu ResetREAD5 RESET6 Total OperationPLU Total Report Hourly Total ReportGrand Total Report Vendor Total Report Individual Total Ex. Individual PLU Total PLU #100Block Total Ex. UPC Block Total UPC #100100~100199 Zone Total Ex. PLU Zone Total PLU #100~107Message Cause Solution Error Message TableProgramming Mode Label Issue Mode Read and Reset ModeCMT Operation Mode Mismatch SpecMitting Data BAD Tape or CMTCleaning the Print Head Clearance 0.5~0.8 mm Label Cutter Peel-off PlateTroubleshooting Before You Call for ServiceProblems Solution SuppliedPage