14. OPERATING PROCEDURES

14.1 WEIGHING OPERATION

14.1 WEIGHING OPERATION

Menu: REG., M. DOWN, or REWRAP

Mode: WEIGH

The weigh mode is used to weigh a commodity and to issue the label. The label contains data such as a weigh, unit price (price per weight) and total price (calculated as a result of the weighing operation). The following is a basic operation seen at the sales floor of a store or at a back room where different kinds and weights of commodities are repacked. Pressing the VOID key subtracts the last entry from the memory.

Example) When PLU #100 and an unit price of $8.00 are set in the speed key #12.

 

 

 

 

 

 

Enter the PLU #.

1

0

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Press: PLU

LB

kg

Press the

12

speed key.

 

The unit of measure can be changed for CA model only.

LB kg

Remote Display

Available only when the initial setting # 5-6 is set to 1.

lb scale

kg scale

100 g

1/4

1/2

Place a commodity on the platter.

(Ex. 1.000 lb.)

MANUAL: PRT

: AUTO

*

 

The label is issued.

Press when canceling

VOID

the last sales.

 

WEIGHT

UNIT PRICE

TOTAL PRICE

 

 

 

1.000

8.00

8.00

REG

Liquid Crystal Display

T-BONE STEAK

 

PACKED ON

 

SELL BY

NET WT.

PRICE lb

 

TEC STORE

 

(TEL) 0123-45-6789

(Sample label)

NOTES: 1. Pressing a speed key to which no PLU data has been assigned will result in an error. In this case, press the C key, then press a speed key to which PLU data has been assigned.

2.To change between AUTO and MANUAL, follow the procedure provided in section 14.9.

3.If a unit price exceeding 4 digits is obtained by multiplying by 2 or 4 (when pressing the 1/2 lb key or 1/4 lb key), the unit price will be 0.

4.

100 g key is available only when the scale is a kg scale or operated on kg base.

5.When the 1/2 lb , 1/4 lb or 100 g key is pressed, the unit price will change on the display.

6.When the “compulsory tare” is selected, a tare must be subtracted in a weighing operation, otherwise an error message “TARE REQUIRED” will be displayed when the following operation has been done:

Manual mode: Pressing the PRT/* key

Auto mode: Placing a commodity on the platter.

Floating vendor mode: Pressing the Vendor key.

When a “TARE REQUIRED” is displayed, refer to Section 14.6 to follow the proper weighing procedure.

14-2

Image 65
Contents SL-9000-ESB Series Page Meanings of Each Symbol Safety SummaryPrecautions Page Page Table of Contents Setting Password and Protect Menu Password SecurityCalling Menu by Entering Password Operating ProceduresIntroduction 9 0 0 0 3 0 M E S B U S AccessoriesApplicable Model Scale SpecificationOption CassetteCMT/PL-3 I/F Main Power Switch Drawer I/FAppearance CA Type DisplayUS Type QR Type Programming Keyboard KEY LayoutProgramming Keyboard Function Name of Key FunctionSets a block PLU # using the confirmation label procedure Inserts a space when entering charactersDisplays the preceding PLU data Used to set an auto codeOperation Keyboard Function Operation Keyboard and Speed KEY BoardPrimary function Secondary function Enters numeric data such as PLU #, unit price and tarePrints the customer label Sets the quantity of commodity in by Count modeDisplays the date Selects the item for change Print/OFFAdjusts the zero point Issues a test labelIssue. Optional key by initial setting Calls the PLU frequently usedSpeed KEY SET Procedure Before OperationNutrition Setting Remote Display Installation ProcedureInstallation Procedure Level Adjustment Removal and Replacement of Media Removal and Replacement of Media Menu selection Outline of OperationHow to Select Menu and Item No Programming ProceduresHow to access the Programming Menu Enter the Password ESB Limited SpecificationTitle and Contents of Programming Menu 2nd line TEL How to enter charactersTEC Store Menu Unit Price ChangeGroup MainMenu PLU Data SettingT1.000 Preset TareQuantity PLU#Open PLU Open PLU Data PLU#DEPT# Group Main Ingredient MessageNutrition Facts Additional Information Area 2~6 ~99999 or 0.0~999.9 Set the Daily Value Table Daily Value Max digits Contents of daily valueMemory file sort Memory file is sorted when a memory full error occursDeleting Nutrition Data Group PLU Verifying LabelAddress Setting Grade Line Special InformationSetting Department/Vendor Number Speed KEY SettingDepartment Number Vendor NumberBy pressing Key Print Format22/38 Label Format Number TablePOS Normal Mode ESB Limited Spec. Mode Menu Group Item No DATE/TIME SettingPL-3 Operation Error code during PL-3 operationSave Key of the PL-3, then check whether the Save LED is onClear Transmission Item ListOperable Inoperable ON-LINE/LOCAL Transmission Delay Time TableUPC # BAR Code FormatExample UPC# PC/D Flag PLU # UPC# PC/D Price WeightC C C C Enter the title. See Note Enter the title # See NoteTitle No Format Additional 221 Additional 231 232Transferring Logo Data Error message during data transmissionTime OUT Error Deleting a vendor number Idiom SettingVendor Setting Enter Free FormatKey functions 11-31 B a C DAvailable format and print items for free format PRT ForSetting Password and Protect Menu Password Security13-2 REG Calling Menu by Entering PasswordHow to access the REG., M.DOWN, or Rewrap menu Operating ProceduresSample label Weighing OperationFIX Price Operation for US Type only Sample label for US type Sample label for CA and QR type By Count Operation14-5 Print Count Operation From the platter Labels are being issued Example B When operating in Fix or By Count modePre=1 PLUFor Issuing Labels with NET Weight Statement for US Type only14-10 Remove the commodity Together with the container TARE/SAVE Function ProceduresCalling and Printing Grade Lines Weight Unit PriceOr C Calling and Printing LogosMenu REG, M.DOWN, or Rewrap Mode WEIGH, FIX, or by Count Selecting Print Item and Adjusting the LCD BrightnessPRT Date ChangeFeed Batch Print Mode with 30 Items Run Assignment Changing a Unit Price and Calling G.Line/LOGO Void Stopping or Canceling Label IssuePreset Count Floating Vendor Price deletion Receipt will be issuedSubtotal Enter vendor #Reset How to access the Read or Reset menuREAD5 RESET6 Total OperationPLU Total Report Hourly Total ReportGrand Total Report Individual Total Ex. Individual PLU Total PLU #100 Vendor Total ReportBlock Total Ex. UPC Block Total UPC #100100~100199 Zone Total Ex. PLU Zone Total PLU #100~107Message Cause Solution Error Message TableProgramming Mode Read and Reset Mode Label Issue ModeMismatch Spec CMT Operation ModeMitting Data BAD Tape or CMTClearance 0.5~0.8 mm Label Cutter Peel-off Plate Cleaning the Print HeadBefore You Call for Service TroubleshootingProblems Solution SuppliedPage