Toshiba EM1-31074EE Speed KEY Setting, Setting Department/Vendor Number, Department Number

Page 43

11. PROGRAMMING PROCEDURES

11.9 SPEED KEY SETTING

11.9 SPEED KEY SETTING

Normal Mode

 

ESB Limited Spec. Mode

Menu Group: 1

Item No.: 8

Item No.:

9

 

 

 

 

The SL-9000 has a maximum of 70x2 speed keys which are very convenient to call PLUs quickly. (Refer to page 5-3 regarding the Key Layout.)

i

<MENU>

Group 1

9

Select the 1st half or the 2nd half of the speed keys.

Enter the Speed

Key number (# 1~70 X 2)

NEXT or

PLU

ENTER

Enter the PLU#.

ENTER

(max. 6 dig.)

 

Setting Department/Vendor Number

i

PROG.

ESC.

<MENU>

Group 1

Main

<MENU>

<MENU>

9

 

 

Group 1

 

 

 

Enter a default

 

 

AUTO

ENTER

 

CODE

department #. (1~99)

 

 

Enter the speed

key number.

ENTER

Enter the department #

or vendor #. (1 ~ 99)

 

Selecting items to be

 

assigned to speed keys.

 

(PLU #/VENDOR #/DEPT #)

ENTER

PROG.

ESC.

<MENU>

Group 1

Main

<MENU>

• Department Number

When initial set #10-6 is set to “1”, the six-digit PLU# is divided into two; the upper two digits are assigned to department #, and the lower four digits to PLU.

The department # is automatically added in front of four-digit PLU# and treated as a six-digit PLU#.

In case of “PROG.”, “Report”, and “Reset” modes, PLU# is treated as a six-digit number. So the upper two digits are not treated as department #. Consequently the four-digit PLU# is available only in “REG.”, “M.DOWM”, and “REWRAP” modes.

NOTE: The default Dept. No. is two-digit serial number ranging from 0 to 99. Entering a “0” clears a Dept. No.

• Vendor Number

Vendor numbers can be set when the Initial Setting #11-1 is set to 1. Vendor numbers are assigned to the speed keys in two ways:

1 Individual vendor number: 00-39

Vendor# is assigned to the speed keys one by one.

2Group vendor number: 0-, 1-, 2- and 3-

Maximum 10 vendor numbers can be assigned to one speed key, resulting in 4 speed keys in total. When assigning group vendor numbers to the speed keys, enter the first digit of the vendor key (0, 1, 2 or 3) plus a bar (-).

Vendor numbers can be called whichever half of the speed keys are selected.

11-17

Image 43
Contents SL-9000-ESB Series Page Meanings of Each Symbol Safety SummaryPrecautions Page Page Table of Contents Operating Procedures Password SecuritySetting Password and Protect Menu Calling Menu by Entering PasswordIntroduction Applicable Model Accessories9 0 0 0 3 0 M E S B U S Cassette SpecificationScale OptionAppearance Main Power Switch Drawer I/FCMT/PL-3 I/F US Type DisplayCA Type QR Type Name of Key Function KEY LayoutProgramming Keyboard Programming Keyboard FunctionUsed to set an auto code Inserts a space when entering charactersSets a block PLU # using the confirmation label procedure Displays the preceding PLU dataEnters numeric data such as PLU #, unit price and tare Operation Keyboard and Speed KEY BoardOperation Keyboard Function Primary function Secondary functionSelects the item for change Print/OFF Sets the quantity of commodity in by Count modePrints the customer label Displays the dateCalls the PLU frequently used Issues a test labelAdjusts the zero point Issue. Optional key by initial settingNutrition Setting Procedure Before OperationSpeed KEY SET Remote Display Installation ProcedureInstallation Procedure Level Adjustment Removal and Replacement of Media Removal and Replacement of Media Menu selection Outline of OperationHow to access the Programming Menu Programming ProceduresHow to Select Menu and Item No Enter the Password ESB Limited SpecificationTitle and Contents of Programming Menu TEC Store How to enter characters2nd line TEL Main Unit Price ChangeMenu GroupMenu PLU Data SettingPLU# Preset TareT1.000 QuantityDEPT# Open PLU Data PLU#Open PLU Group Main Ingredient MessageNutrition Facts Additional Information Area 2~6 ~99999 or 0.0~999.9 Set the Daily Value Table Daily Value Max digits Contents of daily valueDeleting Nutrition Data Memory file is sorted when a memory full error occursMemory file sort Group PLU Verifying LabelAddress Setting Grade Line Special InformationVendor Number Speed KEY SettingSetting Department/Vendor Number Department NumberBy pressing Key Print Format22/38 Label Format Number TablePOS Normal Mode ESB Limited Spec. Mode Menu Group Item No DATE/TIME SettingKey of the PL-3, then check whether the Save LED is on Error code during PL-3 operationPL-3 Operation SaveOperable Inoperable Transmission Item ListClear ON-LINE/LOCAL Transmission Delay Time TableExample BAR Code FormatUPC # C C C C Flag PLU # UPC# PC/D Price WeightUPC# PC/D Additional 231 232 Enter the title # See NoteEnter the title. See Note Title No Format Additional 221Time OUT Error Error message during data transmissionTransferring Logo Data Vendor Setting Idiom SettingDeleting a vendor number Key functions Free FormatEnter 11-31 B a C DAvailable format and print items for free format PRT ForSetting Password and Protect Menu Password Security13-2 REG Calling Menu by Entering PasswordHow to access the REG., M.DOWN, or Rewrap menu Operating ProceduresSample label Weighing OperationFIX Price Operation for US Type only Sample label for US type Sample label for CA and QR type By Count Operation14-5 Print Count Operation From the platter Labels are being issued Example B When operating in Fix or By Count modePre=1 PLUFor Issuing Labels with NET Weight Statement for US Type only14-10 Remove the commodity Together with the container TARE/SAVE Function ProceduresCalling and Printing Grade Lines Weight Unit PriceOr C Calling and Printing LogosMenu REG, M.DOWN, or Rewrap Mode WEIGH, FIX, or by Count Selecting Print Item and Adjusting the LCD BrightnessFeed Date ChangePRT Batch Print Mode with 30 Items Run Assignment Changing a Unit Price and Calling G.Line/LOGO Preset Count Stopping or Canceling Label IssueVoid Floating Vendor Enter vendor # Receipt will be issuedPrice deletion SubtotalTotal Operation How to access the Read or Reset menuReset READ5 RESET6Grand Total Report Hourly Total ReportPLU Total Report Zone Total Ex. PLU Zone Total PLU #100~107 Vendor Total ReportIndividual Total Ex. Individual PLU Total PLU #100 Block Total Ex. UPC Block Total UPC #100100~100199Programming Mode Error Message TableMessage Cause Solution Read and Reset Mode Label Issue ModeBAD Tape or CMT CMT Operation ModeMismatch Spec Mitting DataClearance 0.5~0.8 mm Label Cutter Peel-off Plate Cleaning the Print HeadSupplied TroubleshootingBefore You Call for Service Problems SolutionPage