POWER ADAPTER

 

Type:

Plug power adapter

Input Voltage:

100-240 VAC, 50/60 Hz

Output Voltage:

5 VDC, 2A

Country Specific Adapters:

US (default), Australia, Europe, UK

NOTE: The physical adapter for the wall outlet is interchangeable for use in different countries. The adapter snaps into the plug power supply. Contact your distributor if you need an adapter for a different country. For your own safety, do not open the power supply and never use a do-it-yourself adapter.

PHYSICAL SPECIFICATION

Dimensions:

4.0 (L) x 4.0 (D) x 1.3 (H) inches (10.16 x 10.16 x 3.30 mm)

Weight:

.88 lb (0.4 kg) (without power supply)

ENVIRONMENTAL SPECIFICATION

Operating Temperature:

32° to 104°F (0° to 40° C)

Operating Humidity:

90% maximum relative humidity, non-condensing

ELECTROMAGNETIC EMISSIONS AND SAFETY

Meets requirements of:

EN 55022, EN 50082-1, EN 60950

Pelco Manual C1977M-D (6/02)

[ 67 ]

Image 67
Contents Installation/Operation Contents WEB Browser Control Pages List of Illustrations List of Tables Terminal Command ReferenceRegulatory Notices Important Safeguards and WarningsTransmitter and Receiver Instructions for the Network AdministratorBrowser Remember that the IP address must be unique on the network What is the Pelconet Transmission SYSTEM?Who Should Install The PelcoNet Transmission System? How Do LANs and WANs Work?Software Version Package ContentsOverview DescriptionFront Panel Connectors Front Panel ConnectorsRear Panel Connectors Connecting a Camera Or Monitor Quick Installation GuideConnecting Additional Items Connecting Power Connecting To The LAN PortWhat Next? Using a Web Browser To Configure The NetworkTypical Applications Selecting An IP Address For Your NetworkPelcoNet Home Displaying Video Via a Transmitter-To-Receiver Connection LAN Box-To-Box Connection Transmitter, Receiver, Spectra Diagrams of Typical ApplicationsLAN Browser-To-Box Connection Transmitter, Browser, Spectra Video Data PV130 Genex Browser Spectra WAN Box-To-Box Connection Transmitter, Receiver, Spectra WAN Browser-To-Box Connection Transmitter, Browser, Spectra Video Data PV130 Genex Browser Spectra Connecting Video Sources Or Displays Hardware InstallationConnecting Audio Equipment Control Terminal Port Connecting Data TerminalsTransparent Data Port Transparent Data Port Pin Assignments in RS-232 ModeConnecting To a LAN Configuration Using a Terminal Program ConfigurationTypical Session MAC address unit’s MAC address Command ReferenceWeb Server Concept Configuration Using a Web BrowserPelcoNet Menu Tree PelcoNet Home Pelco Manual C1977M-D 6/02 General Settings Configuration Menu General Settings ConfigurationNew URL to regain connectivity to the unit Configuration Default Settings DescriptionMail reply None Screen For Entering The Password Video Settings Configuration Menu Video Settings ConfigurationFrom 10 Kbps up to 1 Mbps PAL Audio Settings Configuration Menu Audio Settings ConfigurationConfiguration Default Description Settings Alarm Settings Configuration Menu Alarm Settings ConfigurationButton. Click with the right mouse button to deselect a cell Also, there is a choice to keep the status display, once an Live video Off Interface Settings Configuration Menu Interface Settings ConfigurationRS485 Second com port TerminalLive Video and Server Push Video Pages ActiveX Dialog Box Color Setting Dialog Box WEB Browser Control Pages Accessing These PagesControlling The Display Matrix Control Live Video/Server Push Page Contents Genex Live Video/Server Push Page Contents Spectra Live Video/Server Push Page Contents Esprit Live Video/Server Push Page Contents DX3016 Live Video/Server Push Control Page Contents Pelco Manual C1977M-D 6/02 Alarm Notification By E-mail Advanced FeaturesAutomatic Connection Feature Video Motion Detection FeatureRecording The Display Record and Play Back The Display On a PCFirmware Upload Playing Back The RecordingLAN Link LED TroubleshootingGreen Power LED Basic FunctioningTransmit LED Troubleshooting a TCP/IP Network Using a Ping UtilityTerminal Program Troubleshooting The Video Connection Troubleshooting Connection ProblemsTesting The Audio Connection Test Between Audio-Equipped Transmitter and PC DX3000 Warning Reset ButtonCode Definition Network Protocol and Standards Compatibility SpecificationsElectromagnetic Emissions and Safety Glossary Local Area Network Work operating system and using a transport protocolMAC Address Media Access Control/hardware address See Local Area NetworkAppendix a Connecting Pelconet to Various Components Pelco Manual C1977M-D 6/02 KBD4000 Connected to a Multiplexer Pelco Manual C1977M-D 6/02 CM9760KBD Connected to a CM9760-CC1 Controller Pelco Manual C1977M-D 6/02 00529 Using PelcoNet with CM9505 to Provide Remote Control Connecting a PelcoNet Receiver To a System CM9502Using PelcoNet with CM9502 to Provide Remote Control Connecting PelcoNet To a CM9502 Ascii Serial PortUsing PelcoNet with CM8505D to Provide Remote Control Connecting a PelcoNet Receiver To a System CM8500DUsing PelcoNet with CM6700 to Provide Remote Control Connecting PelcoNet To a CM6700 Ascii PortPelco Manual C1977M-D 6/02 Using PelcoNet to Transmit Data and Video Between 9760 Nodes Using PelcoNet to Transmit Data and Video Between 9760 Nodes UsingPelcoNetwithaDX3000Recorder Connecting Pelconet To DX3000 For RecordingPortsetup Protocol CM6800ASCII Coaxitron Pelconet Spectra Connecting a Pelconet Transmitter To The CM6800 Ascii PortSET Serial Port Device Ascii Type Pelconet Remote KBD200 Ascii Mode Setup Can I enlarge the picture size in the browser? Appendix B Frequently Asked Questions FaqsWhat TCP/IP ports does PelcoNet use? Can I view PelcoNet over the Internet?How much bandwidth does PelcoNet use? How do I program PelcoNet with HyperTerminal?Can I use PelcoNet with a DSL or cable connection? Index Mail reply address 35 Mail server IP address Warranty Warranty and Return Information