Connecting PelcoNet To The Com Out RS-422 Port On a Genex Multiplexer
Refer to Figure 43 and the instructions that follow.
00529
Figure 43. Connecting PelcoNet to Genex Using the COM OUT RS-422 Port
1.Verify that the multiplexer has Version 4.1 firmware. (The version number flashes on the monitor when power is applied to the multiplexer.)
2.Set PelcoNet’s transparent data port to 9600 baud, 8 data bits, none (for parity), and 1 stop bit if it is not so set already. This is the default setting.
3.Create a cable using the diagram in Figure 43.
4.Attach the cable’s DB9 connector end to PelcoNet’s transparent data port. Connect the cable’s RJ-45 connector end to COM OUT on the back of the multiplexer.
5.Connect the MAIN video output from the multiplexer to the PelcoNet transmitter.
6.Connect PelcoNet’s Ethernet port to the network using a Cat5 Ethernet patch cable.
[ 76 ] Pelco Manual C1977M-D (6/02)