Invacare 1141448 Removing/Installing the ThinAir Bladder, Removing Inner Cover

Page 5

Removing Inner Cover

NOTE: For this procedure, refer to FIGURE 3 on page 5.

1.Remove the cushion from the outer cover. Refer to Removing Outer Cover on page 4.

2.Unflap the existing inner cover.

3.Remove the cushion from the inner cover.

Installing Inner Cover

NOTE: For this procedure, refer to FIGURE 3.

1. Position the cushion with the ThinAir bladder toward the rear of the new/existing inner cover. NOTE: The back surface of the cushion is marked “REAR”.

2.Slide the cushion into the inner cover.

3.Fold the top flap over and tuck into the bottom of the cover.

4.Fold the bottom flap back.

5.Reinstall the cushion, with inner cover in place, into the outer cover. Refer to Installing Outer Cover on page 4.

ThinAir bladder

NOTE: The ThinAir bladder is an option on the Stabilite OM cushion.

Inner cover

Cushion

Top flap

Bottom flap

FIGURE 3 Removing Inner Cover - Installing Inner Cover

Removing/Installing the ThinAir Bladder

NOTE: For this procedure, refer to FIGURE 4 on page 6.

NOTE: The ThinAir bladder is an option for the InTouch Stabilite OM cushion. To order the ThinAir bladder, contact customer service at 1‐800‐333‐6900.

Removing ThinAir Bladder

1.Remove cushion from inner and outer covers. Refer to Removing/Installing the Cushion Covers on page 4.

2.Unfasten the rear strap and the two side straps.

3.Lift the existing ThinAir bladder and remove it from the cushion.

Part No 1141448

5

InTouch™ Stabilite/Stabilite OM Cushion

Image 5
Contents InTouch Stabilite/Stabilite OM Cushion Important InformationIntroduction Cushion Inspection and CleaningLoop Attachment Strips Attaching/Removing the Cushion To/From Seating SurfaceHook Attachment Strips/No Attachment Strips Removing Outer Cover Removing/Installing the Cushion CoversInstalling Outer Cover Installing Inner Cover Removing/Installing the ThinAir BladderRemoving Inner Cover Removing ThinAir BladderModification for approximately 1/2-inch of obliquity Installing ThinAir BladderModifying the Cushion to Accommodate Obliquity Modifying the Cushion to Accommodate Obliquity Modification for approximately 1-inch of obliquityRemoving/Installing Removable Leg Wedges Removing/Installing Removable Leg WedgesLimited Warranty Stabilite InTouch /Coussin Stabilite OM Information ImportanteCoussin InTouch Stabilite Inspection et nettoyage du coussinHousses intérieure/extérieure Housse extérieureMousse Housse interneBande d’attache à crochets/Pas de bande d’attache Bandes d’attache à bouclesEnlèvement de la housse extérieure Enlèvement/Installation de housses du coussinInstallation de la housse extérieure Enlèvement de la housse intérieure Installation de la housse intérieureEnlèvement de la vessie ThinAir Enlèvement/Installation de la vessie ThinAirInstallation de la vessie ThinAir Modification pour une déviation d’environ 25 mm Modification du coussin pour l’adapter à la déviationModification pour une déviation d’environ 12 mm Modification du coussin pour l’adapter à la déviation Enlèvement/Installation des coins amovibles pour les jambes Enlèvement/Installation des coins amovibles pour les jambesGarantie Limitée Cojín Stabilite/Stabilite OM de InTouch Información importanteInspección y limpieza del cojín IntroducciónTiras adherentes hembra Tiras adherentes macho/sin tiras adherentesInstalación de la funda externa Retiro/instalación de las fundasRetiro de la funda externa Instalación de la funda interna Retiro de la funda internaModificación del cojín para adaptarlo a la oblicuidad Retiro/instalación de la bolsa ThinAirRetiro de la bolsa ThinAir Instalación de la bolsa ThinAirParte superior del cojín Lengüeta Parte inferior del cojín Hacerse en cualquier lado del cojín Retiro/instalación de las cuñas desprendibles para piernasGarantía Limitada