AT&T Not Availab installation instructions DCP Line Interface, Connector Block DCP Jack Interface

Page 18

DCP Line Interface

The DCP line interface is a standard D8W 8-wire modular cord. One pair is used for balanced digital transmission to the PBX switch; another pair is used for balanced digital reception from the PBX switch. A third pair in the 8-wire modular cord provides auxiliary power for the adjunct, and a fourth pair is used only by the CALLMASTER II with Recorder Interface to provide the analog Record Out signals to an external tape recorder.

The 8 line-jack pins are numbered in increasing order from left to right when facing the jack with the tab slot down. The table below shows pin assignments for the line cord and jack block interface.

CONNECTOR BLOCK

 

DCP JACK INTERFACE

Conn. Block

D Inside

 

 

Signal

Pin Number

Wire Color

Pin

Name

Description

3

W-O

1

OD1

Balance output from

 

 

 

 

telephone (power –48V)

4

O-W

2

OD2

Balance output from

 

 

 

 

telephone (power –48V)

5

W-G

3

ID1

Balance input from

 

 

 

 

PBX (power 0V)

1

W-BL

4

REC1

Record output from

 

 

 

 

a CM II with Recorder Interface

 

 

 

U-T*

On a CM III w/o Rec. Interface)

2

BL-W

5

REC2

Record output from

 

 

 

 

a CM II with Recorder Interface

 

 

 

U-R*

On a CM III w/o Rec. Interface)

6

G-W

6

ID2

Balance input from

 

 

 

 

PBX (power 0V)

7

W-BR

7

P1-

Adjunct power –48V

 

 

 

 

(to adjunct jack)

8

BR-W

8

P2+

Adjunct power common

 

 

 

 

(to adjunct jack)

*U-T = ‘‘Tip’’ U-R = ‘‘Ring’’

12

Image 18
Contents AT&T 555-015-168 Comcode 107319659 Issue 1, August DefinityWarranty To Order Copies of this DocumentHearing AID Compatibility Interference Warning Information Part 15 of FCC RulesImportant Safety Instructions Service Contents Your Callmaster Voice Terminal Headset or the HandsetRecorder Interface Organization of this GuideConventions Feature Descriptions CallmasterPage To initiate a self-test of your voice terminal Headset jacks on the side of the Callmaster Installation Checklist of PartsOrderable Equipment ComcodeInstalling the Callmaster Voice Terminals Connecting the Line and Optional Equipment CordsImportant Notes on Installation Line jack, adjunct jack, and routing channelsConnector Block DCP Jack Interface DCP Line InterfacePage Callmaster Testing the Headset or Handset Labeling and Installing the BUTTON-DESIGNATION StripsInserting the designation strips To raise or lower the receive volume Feature ProceduresRaising or Lowering Receive Volume Going OFF-HOOKDisconnecting from Calls Conference To add another party to an existing callDrop HoldTo prevent the other party from hearing you Select Ring and Ringer VolumeMute To select a personalized ringTo adjust ringer volume if necessary SELF-TESTTo test the lights and ringer of your voice terminal Transfer Technical Description Physical Dimension and WeightPower Requirements Environmental Requirements