Siemens SIMATICS PCS7 brochure IEC 870-5-101/IEC 870-5-104 telecontrol protocol

Page 23

© Siemens AG 2011

IEC 870-5-101/IEC 870-5-104 telecontrol protocol

SINAUT

MD741-1

 

 

 

 

 

IEC 60870-5-104

 

 

 

 

 

 

DSL router

 

 

SCALANCE S612,

 

 

 

 

security module

Control center

IEC 60870-5-101

Radio network

SINAUT

MD2

SIPLUS RIC Bundle

SIPLUS RIC Bundle

with SIMATIC S7-400

with SIMATIC S7-300

SIPROTEC

 

IEC 60870-5-101

 

 

7SJ63

 

 

SINAUT

SINAUT

SINAUT

SINAUT

MD741-1

MD741-1

MD2

MD2

IEC 60870-5-103

SIPLUS RIC Bundle

SIPLUS RIC Bundle

SIPLUS RIC Bundle

SIPLUS RIC Bundle

with SIMATIC S7-300

with SIMATIC ET 200S

with SIMATIC ET 200S

with SIMATIC S7-300

Flexible communication options in the WAN with IEC 870-5-101/IEC 870-5-104 telecommunication protocols

G_PCS7_XX_00217

A telecontrol center which is seamlessly integrated into the SIMATIC PCS 7 process control system by means of SIMATIC PCS 7 TeleControl can control and monitor geographically dis- persed outstations via serial (IEC 870-5-101 telecontrol proto- col) or Ethernet TCP/IP (IEC 870-5-104 telecontrol protocol) communication links.

SIMATIC S7 controllers (SIMATIC ET 200S with integral CPU, SIMATIC S7-300/S7-300F, and SIMATIC S7-400/S7-400F/

S7-400H/S7-400FH) as well as third-party RTUs can be used as outstations in this context. The control center is the master during communication with the outstations.

The IEC 870-5-101 and IEC 870-5-104 telecontrol protocols are anchored in the telecommunication product range SIPLUS RIC. Based on specific libraries for telecontrol proto- cols, SIPLUS RIC comprises low-cost bundles for outstations which are based on SIMATIC ET 200S with integral CPU, SIMATIC S7-300 or SIMATIC S7-400.

The performance of the telecontrol stations can be scaled with SIPLUS RIC bundles configured as slaves for the tele- control link as shown below:

Performance

7

SIPLUS RIC Bundle

STEP

with SIMATIC S7-400

 

SIMATIC

with SIMATIC S7-300

 

SIPLUS RIC Bundle

of

 

Parameterization

SIPLUS RIC Bundle with

 

 

SIMATIC ET 200S

 

Data volume

Scalable performance of SIPLUS RIC bundles

IEC 870-5-101/IEC 870-5-104 telecontrol protocol 23

Image 23
Contents Simatic PCS Totally Integrated Automation Totally Integrated AutomationContents Simatic PCS 7 TeleControl Simatic PCS 7 TeleControlProcess control system with integral telecontrol center Automation of widely spread process plantsWater industry Typical application areasOil and gas industries Communication with the outstations remote terminal units Simatic PCS 7 TeleControl system architectureSystem overview Integration in process control EngineeringSimatic S7-400/S7-400F controllers Outstations remote terminal unitsSimatic S7-300/S7-300F controllers Spectrum of outstations and integration versions Combinations of basic topologies and media versions TopologiesBasic topologies Media versionsDual-channel operation Simatic PCS 7 TeleControl system componentsPCS 7 TeleControl Operator System Single-user and multi-user systemsLong-term archiving and logging Simatic PCS 7 TeleControl blocks PCS 7 TeleControl engineering stationData Base Automation DBA RTU Large Simatic S7-400/S7-400F controller Remote terminal unitsPossible tele Information points RTU Medium Simatic S7-300/S7-300F controllerGeneral/elementary telecontrol functions Telecontrol protocolsSinaut ST7 telecontrol protocol Sinaut ST7 telecontrol protocolRange without repeaters example Classic WAN mediaRedundant transmission path TCP/IP-based WAN mediaTechnological configuration with Simatic water library Special characteristics Sinaut ST7 communicationOperating modes 20 DNP3 telecontrol protocol DNP3 telecontrol protocolScalance DNP3 telecontrol protocol22 DNP3 telecontrol protocol Special characteristics of DNP3 communicationIEC 870-5-101/IEC 870-5-104 telecontrol protocol IEC 870-5-101/IEC 870-5-104 telecontrol protocolTCP/IP-based WAN media IEC 870-5-104 telecontrol protocol Classic WAN media IEC 870-5-101 telecontrol protocolRTU ET 200S Modbus telecontrol protocol Modbus telecontrol protocolRedundancy RedundancyIncreasing the plant availability Third-party stations MigrationMigration of existing telecontrol systems Units with Modbus communicationLinking of Siprotec or third-party protection equipment Integration of third-party stations with OPCSinaut LSX systems Application examples Application examplesUniform automation of all stations in the gas network High system availability resulting from redundancyCost-effective RTUs exactly matched to the respective unit Reporting and archiving in compliance withAdditional information