Siemens RS232 Configuration program options, General, Starting the configuration program, Buttons

Page 12

21.4.99

gigam101.fm5

Gigaset V.24 Adapter dt/eng:A30853-X400-B104-3-74D1

Configuration program options

Configuration program options

General

You will rarely need the majority of configuration options for the simple implementation of two Gigaset M101 Data units for cord- less modem operation. A range of settings is available for future developments.

Starting the configuration program

Under Start, select Programs followed by Gigaset M101 Data and finally Set Gigaset.

The configuration program offers a dialog box entitled Proper- ties of Gigaset M101 Data which contains the four tabs Connec- tion, Operating mode, Local station and Partner station.

A number of special fields are also provided for special inputs.

The buttons

The following four operating buttons are available for each tab in the dialog box: OK, Cancel, Apply and Help. These buttons have the following functions:

OK

Accept input, close dialog box

 

 

Cancel

Reject input, close dialog box

 

 

Apply

Accept input, leave dialog box open

 

 

Help

Call up the online help function

 

 

12

Image 12
Contents Gigaset M101 Data Registering a Gigaset M101 Data Setting the operating mode Overview Front BackContents Contents Approval and conformity Introduction What is a Gigaset M101 Data? Safety precautionsPutting into service Putting into serviceChecking the contents of the package Putting into service Installing the program package Prerequisites for installationInstallation Check installation is successfulPutting into service Connecting stations Initial configuration Initial configurationConfiguration program options Configuration program optionsStarting the configuration program GeneralConfiguration program options Connection tab Upper section connecting to the PCLower section radio connection Configuration program options Operating mode tab Setting the operating modeSpecial settings for Direct connection mode Local station tabChanging a name Changing a station type Registering an Teilnehmer station Click RegisterPartner station tab De-registering a Teilnehmer stationChanging the name Changing the PINLEDs and buttons LEDs and buttonsBoth button functions LED 1 Gigaset M101 Data statusPlace of installation What happens ifWhat happens if Technical data Temperature and ambient conditionsSignals to V.24 interfaceName Based on Ccitt Meaning Std. Pin Assign Pin plug based on Ccitt Pole SubD socketWhy set a mode? Technical background Tips & tricks, settings Tips & tricks, settingsOperating from a local station with two remote stations TeilnehmerPC PC direct cable connection via RS232/V.24 interface Setting the direct connection to the correct baud rate Set direct cable connection parameters Activate Hardware under Use flow control in the Settings Tips & tricks, settings Tips & tricks, settings Tips & tricks, settings Sharing files PC PC direct cable connection problems examples MAC and other operating systemsMeaning of lokale Station and Partnerstation Meaning of Basis and TeilnehmerUpdates and news on the Internet SupportConfiguration management Fault Cause Problems with application programs Fault CauseFault Cause Solution Hardware problems PC, modem, Isdn TA Fault Cause SolutionElsa TagGo2000 / Isdn con Acer Isdn T30 terminalMiscellaneous Fault Cause Solution With Elsa Microlink 56k

M101, RS232 specifications

The Siemens RS232 M101 is a notable communication interface device that is widely utilized in industrial applications for data transfer between machines and control systems. Its introduction marked a significant advancement in serial communication technology, allowing for efficient and reliable connectivity in a variety of environments.

One of the primary features of the Siemens RS232 M101 is its adherence to the RS232 standard, which defines the protocols for serial communication. This standard ensures compatibility with a wide range of devices, making it versatile for use in various applications. The M101 facilitates point-to-point communication, enabling direct data exchange between two devices, such as computers, programmable logic controllers (PLCs), and sensors, which is crucial for real-time monitoring and control processes.

The technology behind the M101 includes its ability to support baud rates of up to 115,200 bps, enabling high-speed data transfer. This capability is essential in environments where timely data exchange is critical, such as manufacturing and automation sectors. The device also features a robust design that ensures reliable operation even in challenging industrial conditions, including temperature variations and electromagnetic interference.

Additionally, the Siemens RS232 M101 supports flow control mechanisms such as RTS/CTS (Request to Send/Clear to Send) and XON/XOFF (software flow control), which help manage data transmission effectively. By preventing data loss due to buffer overruns, these technologies enhance the integrity of data being transmitted, providing users with confidence in the reliability of their systems.

The M101 interface is compatible with a variety of operating systems, which simplifies integration into existing setups. Furthermore, it includes diagnostic LEDs that indicate communication status, making troubleshooting straightforward and user-friendly.

In summary, the Siemens RS232 M101 is a pivotal component in industrial communication, characterized by its adherence to RS232 standards, high-speed data transfer capabilities, robust build, and effective flow control mechanisms. Its widespread compatibility and user-friendly features make it a valuable tool for ensuring seamless communication between different systems in industrial applications. By facilitating reliable data exchange, the M101 enhances operational efficiency and contributes to the overall effectiveness of automated processes.