Siemens M101, RS232 operating instructions Set direct cable connection parameters

Page 27

16.4.99

appendix.fm5

Gigaset V.24 Adapter dt/eng:A30853-X400-B104-3-74D1

Tips & tricks, settings

The baud rate (max. 115,200) and HW handshake (default setting) are set in this mask. If you are able to transmit data from one PC to the other, proceed now to the second step.

2.Set direct cable connection parameters

Exit the terminal program at one of the PCs. Select Settings > Control Panel in the Start list under Win95 to open the Control Panel window. Click the System icon (you should now see the System Properties window). Select the Device Manager tab. This folder contains a Modem icon;

double-click this icon to expand the branch. The setting Null- modem cable at COMx should be available. Select the ap- propriate COM port for your configuration and double-click it to open a further subfolder.

27

Image 27
Contents Gigaset M101 Data Registering a Gigaset M101 Data Setting the operating mode Back Overview FrontContents Contents Approval and conformity Safety precautions Introduction What is a Gigaset M101 Data?Putting into service Putting into serviceChecking the contents of the package Check installation is successful Putting into service Installing the program packagePrerequisites for installation InstallationPutting into service Connecting stations Initial configuration Initial configurationGeneral Configuration program optionsConfiguration program options Starting the configuration programConfiguration program options Connection tab Upper section connecting to the PCLower section radio connection Setting the operating mode Configuration program options Operating mode tabSpecial settings for Direct connection mode Local station tabChanging a name Changing a station type Click Register Registering an Teilnehmer stationChanging the PIN Partner station tabDe-registering a Teilnehmer station Changing the nameLED 1 Gigaset M101 Data status LEDs and buttonsLEDs and buttons Both button functionsPlace of installation What happens ifWhat happens if Temperature and ambient conditions Technical dataPin plug based on Ccitt Pole SubD socket Signals toV.24 interface Name Based on Ccitt Meaning Std. Pin AssignWhy set a mode? Technical background Teilnehmer Tips & tricks, settingsTips & tricks, settings Operating from a local station with two remote stationsPC PC direct cable connection via RS232/V.24 interface Setting the direct connection to the correct baud rate Set direct cable connection parameters Activate Hardware under Use flow control in the Settings Tips & tricks, settings Tips & tricks, settings Tips & tricks, settings Sharing files Meaning of Basis and Teilnehmer PC PC direct cable connection problems examplesMAC and other operating systems Meaning of lokale Station and PartnerstationSupport Updates and news on the InternetProblems with application programs Fault Cause Configuration management Fault CauseAcer Isdn T30 terminal Fault Cause SolutionHardware problems PC, modem, Isdn TA Fault Cause Solution Elsa TagGo2000 / Isdn conWith Elsa Microlink 56k Miscellaneous Fault Cause Solution

M101, RS232 specifications

The Siemens RS232 M101 is a notable communication interface device that is widely utilized in industrial applications for data transfer between machines and control systems. Its introduction marked a significant advancement in serial communication technology, allowing for efficient and reliable connectivity in a variety of environments.

One of the primary features of the Siemens RS232 M101 is its adherence to the RS232 standard, which defines the protocols for serial communication. This standard ensures compatibility with a wide range of devices, making it versatile for use in various applications. The M101 facilitates point-to-point communication, enabling direct data exchange between two devices, such as computers, programmable logic controllers (PLCs), and sensors, which is crucial for real-time monitoring and control processes.

The technology behind the M101 includes its ability to support baud rates of up to 115,200 bps, enabling high-speed data transfer. This capability is essential in environments where timely data exchange is critical, such as manufacturing and automation sectors. The device also features a robust design that ensures reliable operation even in challenging industrial conditions, including temperature variations and electromagnetic interference.

Additionally, the Siemens RS232 M101 supports flow control mechanisms such as RTS/CTS (Request to Send/Clear to Send) and XON/XOFF (software flow control), which help manage data transmission effectively. By preventing data loss due to buffer overruns, these technologies enhance the integrity of data being transmitted, providing users with confidence in the reliability of their systems.

The M101 interface is compatible with a variety of operating systems, which simplifies integration into existing setups. Furthermore, it includes diagnostic LEDs that indicate communication status, making troubleshooting straightforward and user-friendly.

In summary, the Siemens RS232 M101 is a pivotal component in industrial communication, characterized by its adherence to RS232 standards, high-speed data transfer capabilities, robust build, and effective flow control mechanisms. Its widespread compatibility and user-friendly features make it a valuable tool for ensuring seamless communication between different systems in industrial applications. By facilitating reliable data exchange, the M101 enhances operational efficiency and contributes to the overall effectiveness of automated processes.