21.4.99

gigam101.fm5

Gigaset V.24 Adapter dt/eng:A30853-X400-B104-3-74D1

Configuration program options

"Operating mode" tab

Important:

If one station is set to "AT commands, local" or "AVM/Eumex commands, local", the other station must switch to the corre- sponding "AT commands, remote" or "AVM/Eumex commands, remote" operating mode. And if one station is switched to "Di- rect connection", the other station must also be switched to this mode. The appropriate switches are performed automatically if you select an operating mode for an Gigaset M101 Data unit.

Setting the operating mode

Open the Operating mode tab and select one of the five modes:

The three connection types are used for different purposes:

Direct connection The transmission parameters for the PC’s COM port are manually set at the compu- ter without automatic baud rate or data for- mat recognition. This is always useful if the device at the Partnerstation does not sup- port baud rate or data format recognition as performed by conventional modems, e.g. in the case of a second PC.

AT commands

Automatic recognition of the transmission

lokalen Station

parameters based on the data from the PC

(PC)

at the lokalen Station.

page 33

 

AT commands

Automatic emulation of the transmission

Partnerstation

parameters based on the values received

(device)

from the PC at the Partnerstation.

page 33

 

AVM / Eumex

Automatic recognition of the AVM / Eumex

lokalen Station

transmission parameters based on the

(PC)

data from the PC at the lokalen Station.

page 34

 

14

Image 14
Contents Gigaset M101 Data Registering a Gigaset M101 Data Setting the operating mode Overview Front BackContents Contents Approval and conformity Introduction What is a Gigaset M101 Data? Safety precautionsChecking the contents of the package Putting into servicePutting into service Installation Putting into service Installing the program packagePrerequisites for installation Check installation is successfulPutting into service Connecting stations Initial configuration Initial configurationStarting the configuration program Configuration program optionsConfiguration program options GeneralLower section radio connection Configuration program options Connection tabUpper section connecting to the PC Configuration program options Operating mode tab Setting the operating modeChanging a name Special settings for Direct connection modeLocal station tab Changing a station type Registering an Teilnehmer station Click RegisterChanging the name Partner station tabDe-registering a Teilnehmer station Changing the PINBoth button functions LEDs and buttonsLEDs and buttons LED 1 Gigaset M101 Data statusWhat happens if Place of installationWhat happens if Technical data Temperature and ambient conditionsName Based on Ccitt Meaning Std. Pin Assign Signals toV.24 interface Pin plug based on Ccitt Pole SubD socketWhy set a mode? Technical background Operating from a local station with two remote stations Tips & tricks, settingsTips & tricks, settings TeilnehmerPC PC direct cable connection via RS232/V.24 interface Setting the direct connection to the correct baud rate Set direct cable connection parameters Activate Hardware under Use flow control in the Settings Tips & tricks, settings Tips & tricks, settings Tips & tricks, settings Sharing files Meaning of lokale Station and Partnerstation PC PC direct cable connection problems examplesMAC and other operating systems Meaning of Basis and TeilnehmerUpdates and news on the Internet SupportConfiguration management Fault Cause Problems with application programs Fault CauseElsa TagGo2000 / Isdn con Fault Cause SolutionHardware problems PC, modem, Isdn TA Fault Cause Solution Acer Isdn T30 terminalMiscellaneous Fault Cause Solution With Elsa Microlink 56k