Configuration program options

"Operating mode" tab

Important:

If one station is set to "AT commands, local" or "AVM/Eumex commands, local", the other station must switch to the corre- sponding "AT commands, remote" or "AVM/Eumex commands, remote" operating mode. And if one station is switched to "Di- rect connection", the other station must also be switched to this mode. The appropriate switches are performed automatically if you select an operating mode for an Gigaset M101 Data unit.

Setting the operating mode

Open the Operating mode tab and select one of the five modes:

The three connection types are used for different purposes:

Direct connection The transmission parameters for the PC’s COM port are manually set at the compu- ter without automatic baud rate or data for- mat recognition. This is always useful if the device at the Partnerstation does not sup- port baud rate or data format recognition as performed by conventional modems, e.g. in the case of a second PC.

AT commands

Automatic recognition of the transmission

lokalen Station

parameters based on the data from the PC

(PC)

at the lokalen Station.

page 33

 

AT commands

Automatic emulation of the transmission

Partnerstation

parameters based on the values received

(device)

from the PC at the Partnerstation.

page 33

 

AVM / Eumex

Automatic recognition of the AVM / Eumex

lokalen Station

transmission parameters based on the

(PC)

data from the PC at the lokalen Station.

page 34

 

14

Image 14
Contents Gigaset M101 Data Registering a Gigaset M101 Data Setting the operating mode Overview Front BackContents Contents Approval and conformity Introduction What is a Gigaset M101 Data? Safety precautionsChecking the contents of the package Putting into servicePutting into service Installation Putting into service Installing the program packagePrerequisites for installation Check installation is successfulPutting into service Connecting stations Initial configuration Initial configurationStarting the configuration program Configuration program optionsConfiguration program options GeneralLower section radio connection Configuration program options Connection tabUpper section connecting to the PC Configuration program options Operating mode tab Setting the operating modeChanging a name Special settings for Direct connection modeLocal station tab Changing a station type Registering an Teilnehmer station Click RegisterChanging the name Partner station tabDe-registering a Teilnehmer station Changing the PINBoth button functions LEDs and buttonsLEDs and buttons LED 1 Gigaset M101 Data statusWhat happens if Place of installationWhat happens if Technical data Temperature and ambient conditionsName Based on Ccitt Meaning Std. Pin Assign Signals toV.24 interface Pin plug based on Ccitt Pole SubD socketWhy set a mode? Technical background Operating from a local station with two remote stations Tips & tricks, settingsTips & tricks, settings TeilnehmerPC PC direct cable connection via RS232/V.24 interface Setting the direct connection to the correct baud rate Set direct cable connection parameters Activate Hardware under Use flow control in the Settings Tips & tricks, settings Tips & tricks, settings Tips & tricks, settings Sharing files Meaning of lokale Station and Partnerstation PC PC direct cable connection problems examplesMAC and other operating systems Meaning of Basis and TeilnehmerUpdates and news on the Internet SupportConfiguration management Fault Cause Problems with application programs Fault CauseElsa TagGo2000 / Isdn con Fault Cause SolutionHardware problems PC, modem, Isdn TA Fault Cause Solution Acer Isdn T30 terminalMiscellaneous Fault Cause Solution With Elsa Microlink 56k

M101, RS232 specifications

The Siemens RS232 M101 is a notable communication interface device that is widely utilized in industrial applications for data transfer between machines and control systems. Its introduction marked a significant advancement in serial communication technology, allowing for efficient and reliable connectivity in a variety of environments.

One of the primary features of the Siemens RS232 M101 is its adherence to the RS232 standard, which defines the protocols for serial communication. This standard ensures compatibility with a wide range of devices, making it versatile for use in various applications. The M101 facilitates point-to-point communication, enabling direct data exchange between two devices, such as computers, programmable logic controllers (PLCs), and sensors, which is crucial for real-time monitoring and control processes.

The technology behind the M101 includes its ability to support baud rates of up to 115,200 bps, enabling high-speed data transfer. This capability is essential in environments where timely data exchange is critical, such as manufacturing and automation sectors. The device also features a robust design that ensures reliable operation even in challenging industrial conditions, including temperature variations and electromagnetic interference.

Additionally, the Siemens RS232 M101 supports flow control mechanisms such as RTS/CTS (Request to Send/Clear to Send) and XON/XOFF (software flow control), which help manage data transmission effectively. By preventing data loss due to buffer overruns, these technologies enhance the integrity of data being transmitted, providing users with confidence in the reliability of their systems.

The M101 interface is compatible with a variety of operating systems, which simplifies integration into existing setups. Furthermore, it includes diagnostic LEDs that indicate communication status, making troubleshooting straightforward and user-friendly.

In summary, the Siemens RS232 M101 is a pivotal component in industrial communication, characterized by its adherence to RS232 standards, high-speed data transfer capabilities, robust build, and effective flow control mechanisms. Its widespread compatibility and user-friendly features make it a valuable tool for ensuring seamless communication between different systems in industrial applications. By facilitating reliable data exchange, the M101 enhances operational efficiency and contributes to the overall effectiveness of automated processes.