Siemens RS232, M101 operating instructions Activate Hardware under Use flow control in the Settings

Page 28

16.4.99

appendix.fm5

Gigaset V.24 Adapter dt/eng:A30853-X400-B104-3-74D1

Tips & tricks, settings

You will find maximum speed setting in the Modem tab; this should be set to 115,200 bps.

Activate Hardware under Use flow control in the Settings -

Advanced tab. Click OK to exit each window.

3.Test the baud rate setting

Open the direct cable connection program via Start > Programs > Accessories.

If this icon is missing, you may have to reinstall the appro- priate software from the Win 95 system CD.

This can be done by selecting Control Panel, Add/Remove Programs, Windows Setup, Communications, Details, Di- rect Cable Connection.

28

Image 28
Contents Gigaset M101 Data Registering a Gigaset M101 Data Setting the operating mode Overview Front BackContents Contents Approval and conformity Introduction What is a Gigaset M101 Data? Safety precautionsPutting into service Putting into serviceChecking the contents of the package Putting into service Installing the program package Prerequisites for installationInstallation Check installation is successfulPutting into service Connecting stations Initial configuration Initial configurationConfiguration program options Configuration program optionsStarting the configuration program GeneralUpper section connecting to the PC Configuration program options Connection tabLower section radio connection Configuration program options Operating mode tab Setting the operating modeLocal station tab Special settings for Direct connection modeChanging a name Changing a station type Registering an Teilnehmer station Click RegisterPartner station tab De-registering a Teilnehmer stationChanging the name Changing the PINLEDs and buttons LEDs and buttonsBoth button functions LED 1 Gigaset M101 Data statusWhat happens if Place of installationWhat happens if Technical data Temperature and ambient conditionsSignals to V.24 interfaceName Based on Ccitt Meaning Std. Pin Assign Pin plug based on Ccitt Pole SubD socketWhy set a mode? Technical background Tips & tricks, settings Tips & tricks, settingsOperating from a local station with two remote stations TeilnehmerPC PC direct cable connection via RS232/V.24 interface Setting the direct connection to the correct baud rate Set direct cable connection parameters Activate Hardware under Use flow control in the Settings Tips & tricks, settings Tips & tricks, settings Tips & tricks, settings Sharing files PC PC direct cable connection problems examples MAC and other operating systemsMeaning of lokale Station and Partnerstation Meaning of Basis and TeilnehmerUpdates and news on the Internet SupportConfiguration management Fault Cause Problems with application programs Fault CauseFault Cause Solution Hardware problems PC, modem, Isdn TA Fault Cause SolutionElsa TagGo2000 / Isdn con Acer Isdn T30 terminalMiscellaneous Fault Cause Solution With Elsa Microlink 56k

M101, RS232 specifications

The Siemens RS232 M101 is a notable communication interface device that is widely utilized in industrial applications for data transfer between machines and control systems. Its introduction marked a significant advancement in serial communication technology, allowing for efficient and reliable connectivity in a variety of environments.

One of the primary features of the Siemens RS232 M101 is its adherence to the RS232 standard, which defines the protocols for serial communication. This standard ensures compatibility with a wide range of devices, making it versatile for use in various applications. The M101 facilitates point-to-point communication, enabling direct data exchange between two devices, such as computers, programmable logic controllers (PLCs), and sensors, which is crucial for real-time monitoring and control processes.

The technology behind the M101 includes its ability to support baud rates of up to 115,200 bps, enabling high-speed data transfer. This capability is essential in environments where timely data exchange is critical, such as manufacturing and automation sectors. The device also features a robust design that ensures reliable operation even in challenging industrial conditions, including temperature variations and electromagnetic interference.

Additionally, the Siemens RS232 M101 supports flow control mechanisms such as RTS/CTS (Request to Send/Clear to Send) and XON/XOFF (software flow control), which help manage data transmission effectively. By preventing data loss due to buffer overruns, these technologies enhance the integrity of data being transmitted, providing users with confidence in the reliability of their systems.

The M101 interface is compatible with a variety of operating systems, which simplifies integration into existing setups. Furthermore, it includes diagnostic LEDs that indicate communication status, making troubleshooting straightforward and user-friendly.

In summary, the Siemens RS232 M101 is a pivotal component in industrial communication, characterized by its adherence to RS232 standards, high-speed data transfer capabilities, robust build, and effective flow control mechanisms. Its widespread compatibility and user-friendly features make it a valuable tool for ensuring seamless communication between different systems in industrial applications. By facilitating reliable data exchange, the M101 enhances operational efficiency and contributes to the overall effectiveness of automated processes.