Siemens M101, RS232 operating instructions Initial configuration

Page 11

21.4.99

gigam101.fm5

Gigaset V.24 Adapter dt/eng:A30853-X400-B104-3-74D1

Initial configuration

Initial configuration

The purpose of initial configuration is to register the Teilnehmer station at the Basis station. You can only perform initial configu- ration with the configuration program. The Gigaset M101 Data can be operated at other PCs/operating systems once you have completed initial configuration.

Proceed as follows:

1.Disconnect both stations and the PC from the power sup- ply.

2.Connect one Gigaset M101 Data to the PC.

3.Connect the PC and both Gigaset M101 Data units to the power supply.

4.Start the program "Set Gigaset" at the PC.

5.Select the "Local station" tab.

6.Click the "Register" button.

The lokale Station is now switched to "Teilnehmer" operat- ing mode. Normally, you must enter the Basis station PIN before registration is possible. In the case of initial configu- ration, however, you can skip this step since the Basis sta- tion has the factory-set PIN "0000". This is automatically set by the program during initial configuration.

7.Press and hold down the black button on the Gigaset M101 Data (Basis station) not connected to the PC for approx. 10 seconds until the LEDs indicate by blinking in sequence that the system is ready for registration.

8.Click OK. The registration procedure starts and the mes- sage "The Teilnehmer logs on at the required Basis if this is ready for registration. Ensure that the Basis is ready for reg- istration." appears on the screen.

The two devices are automatically synchronised. An entry is now visible in the "Registered stations" windows.

9.Assign a suitable name to the lokale Station, e.g. "PC".

10.Open the "Partner station" window and assign a name to it, e.g. "Modem". The registered station now also appears in this window.

11.It may be useful to switch the operating mode from "AT commands, local" to one of the two other operating modes. This setting concerns the protocol on the serial interface, especially the speed adjustment. For details, see "Setting the operating mode" on page 14.

12.Close the program with "OK".

In the event of errors and for more information, see "Configura- tion program options" on page 12.

11

Image 11
Contents Gigaset M101 Data Registering a Gigaset M101 Data Setting the operating mode Back Overview FrontContents Contents Approval and conformity Safety precautions Introduction What is a Gigaset M101 Data?Checking the contents of the package Putting into servicePutting into service Check installation is successful Putting into service Installing the program packagePrerequisites for installation InstallationPutting into service Connecting stations Initial configuration Initial configurationGeneral Configuration program optionsConfiguration program options Starting the configuration programLower section radio connection Configuration program options Connection tabUpper section connecting to the PC Setting the operating mode Configuration program options Operating mode tabChanging a name Special settings for Direct connection modeLocal station tab Changing a station type Click Register Registering an Teilnehmer stationChanging the PIN Partner station tabDe-registering a Teilnehmer station Changing the nameLED 1 Gigaset M101 Data status LEDs and buttonsLEDs and buttons Both button functionsWhat happens if Place of installationWhat happens if Temperature and ambient conditions Technical dataPin plug based on Ccitt Pole SubD socket Signals toV.24 interface Name Based on Ccitt Meaning Std. Pin AssignWhy set a mode? Technical background Teilnehmer Tips & tricks, settingsTips & tricks, settings Operating from a local station with two remote stationsPC PC direct cable connection via RS232/V.24 interface Setting the direct connection to the correct baud rate Set direct cable connection parameters Activate Hardware under Use flow control in the Settings Tips & tricks, settings Tips & tricks, settings Tips & tricks, settings Sharing files Meaning of Basis and Teilnehmer PC PC direct cable connection problems examplesMAC and other operating systems Meaning of lokale Station and PartnerstationSupport Updates and news on the InternetProblems with application programs Fault Cause Configuration management Fault CauseAcer Isdn T30 terminal Fault Cause SolutionHardware problems PC, modem, Isdn TA Fault Cause Solution Elsa TagGo2000 / Isdn conWith Elsa Microlink 56k Miscellaneous Fault Cause Solution

M101, RS232 specifications

The Siemens RS232 M101 is a notable communication interface device that is widely utilized in industrial applications for data transfer between machines and control systems. Its introduction marked a significant advancement in serial communication technology, allowing for efficient and reliable connectivity in a variety of environments.

One of the primary features of the Siemens RS232 M101 is its adherence to the RS232 standard, which defines the protocols for serial communication. This standard ensures compatibility with a wide range of devices, making it versatile for use in various applications. The M101 facilitates point-to-point communication, enabling direct data exchange between two devices, such as computers, programmable logic controllers (PLCs), and sensors, which is crucial for real-time monitoring and control processes.

The technology behind the M101 includes its ability to support baud rates of up to 115,200 bps, enabling high-speed data transfer. This capability is essential in environments where timely data exchange is critical, such as manufacturing and automation sectors. The device also features a robust design that ensures reliable operation even in challenging industrial conditions, including temperature variations and electromagnetic interference.

Additionally, the Siemens RS232 M101 supports flow control mechanisms such as RTS/CTS (Request to Send/Clear to Send) and XON/XOFF (software flow control), which help manage data transmission effectively. By preventing data loss due to buffer overruns, these technologies enhance the integrity of data being transmitted, providing users with confidence in the reliability of their systems.

The M101 interface is compatible with a variety of operating systems, which simplifies integration into existing setups. Furthermore, it includes diagnostic LEDs that indicate communication status, making troubleshooting straightforward and user-friendly.

In summary, the Siemens RS232 M101 is a pivotal component in industrial communication, characterized by its adherence to RS232 standards, high-speed data transfer capabilities, robust build, and effective flow control mechanisms. Its widespread compatibility and user-friendly features make it a valuable tool for ensuring seamless communication between different systems in industrial applications. By facilitating reliable data exchange, the M101 enhances operational efficiency and contributes to the overall effectiveness of automated processes.