Siemens RS232 LEDs and buttons, Both button functions, LED 1 Gigaset M101 Data status

Page 19

21.4.99

gigam101.fm5

Gigaset V.24 Adapter dt/eng:A30853-X400-B104-3-74D1

LEDs and buttons

LEDs and buttons

There are two LEDs and a black button on the front of the Gigas- et M101 Data unit.

Both button functions

Setting a Basis to logon mode

Press the button on a powered base-type device for 10 seconds. The two LEDs blink in sequence, thus indicating that the device is in logon mode. Logon mode is automatically deactivated after successful logon or after 10 minutes: the blinking stops.

Resetting the device to the factory default

Press and hold down the button on the device that has been dis- connected from the mains. Connect the device to the power supply while holding the button down. LED 2 lights up after 10 seconds. This LED goes out in another 10 seconds indicating that the reset operation has been successful. The button can then be released.

LED 1: Gigaset M101 Data status

LED 1 indicates stand-by mode:

LED 1 blinks

The station is searching for the part-

 

ner or has not been registered.

LED 1 is constantly il- luminated

The partner was found, the transmis- sion route is on stand-by.

LED 2: data transfer

LED 2 indicates the status of the transmission route on the

V.24/RS232 interface:

LED 2 off

No data transfer

LED 2 flickers

Data transfer active

19

Image 19
Contents Gigaset M101 Data Registering a Gigaset M101 Data Setting the operating mode Back Overview FrontContents Contents Approval and conformity Safety precautions Introduction What is a Gigaset M101 Data?Putting into service Putting into serviceChecking the contents of the package Check installation is successful Putting into service Installing the program packagePrerequisites for installation InstallationPutting into service Connecting stations Initial configuration Initial configurationGeneral Configuration program optionsConfiguration program options Starting the configuration programUpper section connecting to the PC Configuration program options Connection tabLower section radio connection Setting the operating mode Configuration program options Operating mode tabLocal station tab Special settings for Direct connection modeChanging a name Changing a station type Click Register Registering an Teilnehmer stationChanging the PIN Partner station tabDe-registering a Teilnehmer station Changing the nameLED 1 Gigaset M101 Data status LEDs and buttonsLEDs and buttons Both button functionsWhat happens if Place of installationWhat happens if Temperature and ambient conditions Technical dataPin plug based on Ccitt Pole SubD socket Signals toV.24 interface Name Based on Ccitt Meaning Std. Pin AssignWhy set a mode? Technical background Teilnehmer Tips & tricks, settingsTips & tricks, settings Operating from a local station with two remote stationsPC PC direct cable connection via RS232/V.24 interface Setting the direct connection to the correct baud rate Set direct cable connection parameters Activate Hardware under Use flow control in the Settings Tips & tricks, settings Tips & tricks, settings Tips & tricks, settings Sharing files Meaning of Basis and Teilnehmer PC PC direct cable connection problems examplesMAC and other operating systems Meaning of lokale Station and PartnerstationSupport Updates and news on the InternetProblems with application programs Fault Cause Configuration management Fault CauseAcer Isdn T30 terminal Fault Cause SolutionHardware problems PC, modem, Isdn TA Fault Cause Solution Elsa TagGo2000 / Isdn conWith Elsa Microlink 56k Miscellaneous Fault Cause Solution

M101, RS232 specifications

The Siemens RS232 M101 is a notable communication interface device that is widely utilized in industrial applications for data transfer between machines and control systems. Its introduction marked a significant advancement in serial communication technology, allowing for efficient and reliable connectivity in a variety of environments.

One of the primary features of the Siemens RS232 M101 is its adherence to the RS232 standard, which defines the protocols for serial communication. This standard ensures compatibility with a wide range of devices, making it versatile for use in various applications. The M101 facilitates point-to-point communication, enabling direct data exchange between two devices, such as computers, programmable logic controllers (PLCs), and sensors, which is crucial for real-time monitoring and control processes.

The technology behind the M101 includes its ability to support baud rates of up to 115,200 bps, enabling high-speed data transfer. This capability is essential in environments where timely data exchange is critical, such as manufacturing and automation sectors. The device also features a robust design that ensures reliable operation even in challenging industrial conditions, including temperature variations and electromagnetic interference.

Additionally, the Siemens RS232 M101 supports flow control mechanisms such as RTS/CTS (Request to Send/Clear to Send) and XON/XOFF (software flow control), which help manage data transmission effectively. By preventing data loss due to buffer overruns, these technologies enhance the integrity of data being transmitted, providing users with confidence in the reliability of their systems.

The M101 interface is compatible with a variety of operating systems, which simplifies integration into existing setups. Furthermore, it includes diagnostic LEDs that indicate communication status, making troubleshooting straightforward and user-friendly.

In summary, the Siemens RS232 M101 is a pivotal component in industrial communication, characterized by its adherence to RS232 standards, high-speed data transfer capabilities, robust build, and effective flow control mechanisms. Its widespread compatibility and user-friendly features make it a valuable tool for ensuring seamless communication between different systems in industrial applications. By facilitating reliable data exchange, the M101 enhances operational efficiency and contributes to the overall effectiveness of automated processes.