Motorola RDM2020, rdm2080d manual Configuring a Frequency, Configuring a Code

Page 56

ADVANCED CONFIGURATION

Configuring a Frequency

Assuming current frequency value is set up to channel 1, with the MURs default frequency “1” (equivalent to 154.60000 MHz), and it will be changed to Frequency Number = “4” (which is mapped to 151.88000 MHz), follow the sequence below:

1.Enter Advanced Configuration Mode.

2.Short press the PTT button to enter Frequency Mode. Radio will signal current value “1” with one beep (a red blinks).

3.Press the SB1 button once to increase digit to “2” (two beeps & two red blinks).

4.Press the SB1 button once to increase digit to “3” (three beeps & three red blinks).

5.Press the SB1 button again to increase digit to “4” (four beeps & four red blinks).

6.Long press the PTT button. LED indicator will show a green heartbeat to indicate “Idle” state.

7.Long press the PTT button to exit Advanced Configuration Mode or turn the radio OFF.

Configuring a Code

Assuming current code value is set to factory default “001”, and it will be changed to CTCSS/ DPL Code = 103 follow the sequence below:

1.Enter Advanced Configuration Mode.

2.Short press the PTT button three times (Enter CTCSS/DPL Programming Selection Mode). Radio LED will blink orange to indicate that current value is “0”.

3.Press the SB1 button once (to change first digit to “1”) LED indicator blinks red.

4.Short press the PTT button (to move forward and program second digit). Radio LED blinks orange to indicate current value is “0”.

5.Short press the PTT button and move ahead to program the third digit. LED indicator blinks red to indicate current value is “1”.

6.Press the SB1 button to change the ‘third digit’ to “2”. Press the SB1 button to change again this “third digit” to “3”. The radio will signal the chosen value.

English 48

Image 56
Contents RDM Series Murs Two-Way Radios Page Contents Advanced Configuration Iii English Safety SafetyBatteries Chargers Safety Information Batteries and Chargers Safety Information Operational Safety GuidelinesIntroduction Package ContentsIntroduction Canada TelephoneUSA Regulation on Murs MULTI-USE Radio Service Frequencies FCC Licensing InformationDisplay Model RDM2080d Radio OverviewRadio Overview NON-DISPLAY Model RDM2020 On/Off/Volume Knob Accessory ConnectorLED Indicator Channel Selector KnobConfigurable Buttons ScrambleIcons Chart RDM2080d Model Icon Symbol CommentsBattery Features About the Li-Ion BatteryBattery Recycling and Disposal RadioBattery DROP-IN Tray Charger and Power SupplyInstalling the Battery Removing the BatteryOverview RadioAlkaline Battery Pack Optional Installing Alkaline Batteries Li-Ion Battery Life Alkaline Battery Life Battery Meter RDM2080d Model Charging the Battery Charging The Battery Attached to the RadioCharging a Standalone Battery Charging a Standard BatteryCharging a High Capacity or Ultra High Capacity Battery Drop-in Tray Charger LED Indicators Standard Charger LED IndicatorRapid Charger LED Indicator Charging Battery Type Solution Estimated Charging TimeCharging Batteries using a Multi Unit Charger- MUC Optional MUC LED IndicatorInstalling Spring Action Belt Clip Belt Clip Tab Spring Action BeltAdjusting Volume Getting StartedGetting Started Turning Radio ON/OFFSelecting a Channel Talking and MonitoringReceiving a Call ScanSignal Strength and Channel Busy Indicators RDM2080d Model While receiving, the radio displays the strengthLOW Battery Alert Talk RangeTransmit Time-Out Timer Computer Programming SoftwareAlternate Battery Selection PL Reverse BurstRadio Cloning Cloning with a Multi-Unit Charger MUCBasic Configuration Basic ConfigurationBattery Save Menu Options RDM2080d ModelBattery Type Settings RDM2080d Model Channel Alias RDM2080d ModelCloning Mode Roger Beep Tone END of Transmission Tone Keypad Beep RDM2080d ModelKeypad LOCK/UNLOCK RDM2080d Model VOX Voice Operated TransmitTransmit RDM2080d Model VOX/IVOX Sensitivity Settings RDM2080d ModelIvox Internal Voice Operated Ivox Nuisance Channel DeleteReset to Factory Defaults PL DefeatAdvanced Configuration Advanced ConfigurationAdvanced Configuration RDM2080d Model Advanced ConfigurationOther Advanced Configurations RDM2080d Model only Call Tone Microphone Gain LevelTo configure Accessory Microphone Gain ScrambleSide Button Preset to Channel Select Advanced Configuration RDM2020 Model CTCSS/DPLReading Values Through Beeps and LED Indicators Number Confirmation Beep LED IndicationReading Frequency Values Reading CTCSS/DPL ValuesReading Auto-Scan Values Changing ValuesConfiguring a Frequency Configuring a CodeConfiguring Auto-Scan RDM Series Murs Frequency Chart Frequency and Code ChartsFrequency and Code Charts RDM2020 Murs Non-Display Model Default Frequencies and Codes Frequency and Code Charts Ctcss and PL/DPL Codes Ctcss CodesPL/DPL Codes 654 129 Customized PL 445 112 662 130 139 190 USE and Care USE and CareTroubleshooting TroubleshootingRange. Check for clear line of sight to improve transmission Radios are too close they must be at least five feet apart VOX feature might be set to OFF Warranty for Motorola LimitedUnited States CanadaWarranty ExclusionsHOW to Obtain Warranty Service or Other INFORMATION? SoftwareWHO is COVERED? Software Copyright NoticePatent Notice Export LAW AssurancesAccessories AccessoriesAudio Accessories BatteryPower Supplies AC PIN Adaptors Power SuppliesSoftware Applications CablesAccessories Page 68012002002