![](/images/new-backgrounds/1197515/197515153x1.webp)
Chapter 5 Configuring | |
|
|
7.Display the Signal Profile Configuration menu, enter a desired signaling system profile number (1) and configure it according to the system used by the PBX connected to the
8.Display the Hub menu and enter the existing main link card
Configuring E1 Main Link Parameters
Configuring the E1 main link parameters:
1.Display the Main Link menu, and configure the E1 main link parameters to the following values (Main Menu > Configuration > Card > Main Board >
E1 Parameters > Main Link 1): Connect – Yes
Frame – G.732N Restoration – CCITT Clock Source – Lbt Interface Type – Dsu Idle Code – 7E.
2.Display the Time Slot Table menu and assign the timeslots to carry data
(Main Menu > Configuration > Card > Main Board > E1 Parameters > Time Slot Table):
Yes – connected (assigned)
No – disconnected (not assigned).
Configuring Voice Card Parameters
Configuring the voice card parameters:
1.Display the Group 1 menu, and assign the 172.17.15.11 IP address to the group 1 (Main Menu > Configuration > Card > Slot 1 > Group 1).
2.Display the Bundle Configuration menu, and add bundle 1 to the system (Main Menu > Configuration > Card > Slot 1 > Group 1 > Bundles Parameters > Bundle Configuration).
3.Display the Edit Bundle menu, and configure the group 1 bundle 1 parameters to the following values (Main Menu > Configuration > Card > Slot 1 > Group 1 > Bundles Parameters > Bundle Configuration > Edit Bundle):
Connect – Yes Function – TDMoIP
Max Bytes In Multiplexed Frame – 500 Destination IP – 172.17.15.21 Destination Bundle – 1
Packetizing Interval – 30 Coder/Rate – G.723.1/6.4 Fax/Modem – Enable at 9.6 kbps.
AM | Configuring |