Chapter 5 Configuring | |
|
|
4.Display the E1 Parameters menu, and set the E1 port of group 1 to the following values (Main Menu > Configuration > Card > Slot 1 > Group 1 > External 1 > E1 Parameters):
Connect – Yes
Frame – G.732S
Restoration – CCITT
Clock Source – Lbt
Interface Type
Idle Code – 7E
Signaling – CAS
Profile – 1.
5.Display the Time Slot Configuration menu, and configure the timeslots belonging to the external port 1 of group 1 (Main Menu > Configuration > Card > Slot 1 > Group 1 > External 1 >
Distribution Of Framer Time Slots > Time Slot Configuration): Update from Time Slot – 1
To Time Slot – 31 Type – Voice Bundle – 1 Destination Port ID – 1 Destination Time Slot ID – 1.
Note
6.Update the timeslot database from the Time Slot Configuration menu.
7.Repeat step 4 to step 6 for the external port 2 of group 1, except for the following:
Assign 2 to the Destination Port ID for the timeslots in step 5.
8.Display the Group 2 menu, and assign the 172.17.15.12 IP address to the group 2 (Main Menu > Configuration > Card > Slot 1 > Group 2).
9.Repeat step 3 to step 6 for the external port 1 of group 2, except for the following:
Assign destination IP 172.17.15.21 to the bundle 1 in step 2 Assign 3 to the Destination Port ID for the timeslots in step 5.
10.Repeat step 4 to step 6 for the external port 2 of group 2, except for the following:
Assign 4 to the Destination Port ID for the timeslots in step 5.
Figure 5-2 summarizes the external E1 bundle and timeslot configuration of the local and remote units.
Configuring | AM |