Chapter 4 Management from a Terminal | |
|
|
Idle Code (code transmitted to fill unused timeslots in the E1 frames): 00 to ff.
4.From the E1 Parameters menu, choose Time Slot Table to assign the E1 main link to carry the user data (and idle code).
The Time Slot Table menu appears.
Timeslots that are connected (assigned to carry data) are marked Yes; timeslots that are disconnected (not assigned) are marked No.
Time Slot Table |
|
|
|
|
|
|
|
|
|
|
| |
Ts# | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 |
| Yes | Yes | Yes | No | No | No | No | No | No | No | No | No |
Ts# | 13 | 14 | 15 | 16 | 17 | 18 | 19 | 20 | 21 | 22 | 23 | 24 |
| No | No | No | No | Yes | No | No | No | No | No | No | No |
Ts# | 25 | 26 | 27 | 28 | 29 | 30 | 31 |
|
|
|
|
|
| No | No | No | No | No | No | No |
|
|
|
|
|
1. No
2. Yes
>
@ - Db Update; # - Db Undo
Figure 4-26. Time Slot Table (for E1 Link)
5.From the Time Slot Table, toggle between timeslots by pressing <Tab>, and assign the timeslot(s) that are to carry data by entering Yes. To disconnect a timeslot, enter No.
Note Since
Configuring the T1 Main Link Port
The procedure for configuring the T1 main link port is similar to the procedure described above for configuring the E1 main link port. The following parameters, which are configured via the Main Link 1 or Main Link 2 menu (see Figure