DKS Enterprises 1817, 1815, 1803PC General Programming Information, Programming with a PC

Page 29

SECTION 3 – PROGRAMMING

IMPORTANT! Many of the advanced features available with this telephone entry system cannot be programmed from the system keypad. These features include relay hold open time zones, security levels, and elevator control options. If any of these features are used, the system must be programmed with the DoorKing Remote Account Manager for Windows software, VERSION 5.0. Refer to the software User's Manual for more information on these features.

We strongly suggest that you read these programming instructions in their entirety before beginning any programming of this telephone entry system.

3.1 GENERAL PROGRAMMING INFORMATION

The DoorKing PC Programmable Telephone Entry System is primarily programmed by using the DoorKing Remote Account Manager for Windows software and the user supplied PC by either RS- 232 connection or by modem, however it can also be programmed from the keypad on the front of the entry system. When programming from an off site location with a PC, the RING pin must be installed on the circuit board.

The PC programmable telephone entry systems have three relays on the circuit board, all of which are programmable for any function required. These relays are designated as Relay 0 (R-0), Relay 1 (R-1), and Relay 2 (R-2). If Tracker expansion boards are used with this system, it is very important that you understand the function of these three relays. The weigand input auxiliary terminals (also the Tracker board input terminals) can only cause R-1 or R-2 to activate. Weigand input devices cannot cause R-0 to activate. Therefore, if Tracker expansion boards are used with this system, R-0 must be designated as the PRIMARY relay, and R-1 and R-2 are then designated as Tracker board command (CMD) relays with R-2 controlling tracker boards 1 through 8 (system relays 3-10), and R-1 controlling tracker boards 9 through 16 (system relays 11-18). The PRIMARY relay is the relay that a resident activates from their telephone after receiving a call from a visitor. When tracker boards or other weigand devices are used with the system, be sure that R-0 is programmed to respond to the tone open number (typically 9), the postal switch input, and the rotary dial 9 function.

Refer to the Remote Account Manager User's Manual for more information on Tracker board relay numbering scheme and designations.

3.1.1 Programming with a PC

Prior to programming the system with a personal computer and the DoorKing Remote Account Manager for Windows software, there is certain information that you must know and must program into the system before the computer can communicate with the system. See page 24 to set-up the telephone entry system for PC programming. Programming the system with a PC may be accomplished either by modem or by direct connection using the RS-232 communications terminal on the circuit board. Using the RS-232 communications terminal will require the use of a cable with a DB-9 connector on one end (DoorKing P/N 1818-040), and the DoorKing Remote Account Manager for Windows software VERSION 5.0.

29

Image 29
Contents 1803PC, 1815, 1817 PC Programmable Telephone Entry Systems Page Use this manual with the following models only Table of Contents Adjustments Listing Important NoticeGeneral Information Features Installation Guidelines ALL Systems InstallationSurface Mount Units Surface Mount Units with Recess Box Flush Mount Units Flush Mount Rough-in Box Flush Mount Trim Ring Flush Mount Surface Mounting Kit Wall Mount Units Memory Chip Installation Postal Lock Installation Wiring 18AWG Terminal Description Main Terminal DescriptionWeigand Data Terminals Weigand Power TerminalsWeigand Terminal Description 4 RS-232 Terminals Elevator Control TerminalsControlling a Single Door or Gate Relay Wiring TypicalControlling a Gate Operator and Pedestrian Gate or Door Magnetic Lock Electric Strike Gate Operator Tracker Expansion Board Control Page Programming with a PC General Programming InformationProgramming from the Keypad System Memory Standard Chip MemPLUS ChipSingle or Multiple Systems Programming with a PCMaster Code PC Programming Table Programming for Call-up OperationTalk Time General ProgrammingRelay Strike Time Tone Open Numbers Postal SwitchRotary-dial Touch-tone / Rotary-dialProgramming Letters and Numbers Programming LETTERS, Numbers and MessagesProgramming the User Message 1815 Systems Programming the Instruction Message 1815 Systems Programming the User Message 1817 Systems Programming the Instruction Message 1817 Systems Programming Phone Numbers and Names Programming 7-digit Phone Numbers Programming the Directory Code LengthProgramming Phone Numbers with Area Code Reference Programming Area CodesDelete Names 1815, 1817 Systems Only Programming Names 1815, 1817 Systems OnlyDeleting Individual Phone Numbers Display Phone Numbers 1815, 1817 Systems Only Delete Area CodesDeleting Device Codes Programming Device CodesProgramming Device Codes Programming Four-digit Entry Codes FOUR-DIGIT Entryt CodesDelete Four-digit Entry Codes Entry Code RangesFeedback Speaker VolumeClick Sensitivity Display Contrast 1815 OnlyBack-light Cutoff 1817 Only Master Code SwitchRing Pin Relay 2 Contact PinAdjustment Locations SEC Level Back Light Contrast Lower Contrast Upper Volume Guest Instructions Operating InstructionsResponding to a Guest Call Using an Entry CodeResident Instructions Opening from a Remote Location System AdministratorTracker Board Override Hold Open Command Time and Date Check Relay CheckLine Sharing Miscellaneous Operating InstructionsConnection to a PBX Areas with 10-digit DialingPage Trouble Shooting MaintenanceSympton Possible Solutions 1 RS-232 Test Will be erased when this function is performedElevator Boards Hardware Test Weigand Test 1815, 1817 Systems OnlyElevator Board / Floor Hardware Test Accessories LOG Tables Name AAC Phone Number DIR Code ENT Device SEC FL ER Level Access Code Granting or Denying AccessGuest Communication Call Waiting

1815, 1803PC, 1817 specifications

DKS Enterprises has established itself as a leading provider of cutting-edge access control solutions, and among its notable offerings are the 1803PC, 1817, and 1815 models. These products stand out in the commercial security landscape, providing businesses with reliable and efficient entry management.

The DKS 1803PC is an advanced digital keyless entry system designed for commercial applications. Its primary feature is the easy-to-use keypad interface, which allows users to input their access codes directly. This model is equipped with a robust memory capable of storing up to 100 unique codes, making it suitable for locations with multiple users. Additionally, the 1803PC supports timed access, enabling businesses to set specific entry windows, which enhances security and access control.

The DKS 1817 model takes entry management a step further with its smart technology integration. It features Bluetooth capabilities that allow users to unlock doors via their smartphones, offering convenience and flexibility. The 1817 can be connected to various security devices, such as alarms and surveillance cameras, providing a comprehensive security ecosystem. It also includes a user-friendly mobile app that enables remote management of access permissions, ensuring that business owners can monitor and control entry points effectively from anywhere.

In contrast, the DKS 1815 model caters to businesses looking for a cost-effective yet reliable access solution. This model features a straightforward keypad interface similar to the 1803PC, but it is designed with essential functionalities to meet basic security needs. The 1815 supports up to 50 access codes and is ideal for smaller businesses or limited access areas. Its durable construction ensures longevity and requires minimal maintenance over time.

All three models employ DKS's proprietary technology that emphasizes durability and security. They are built to withstand harsh environmental conditions, making them suitable for both indoor and outdoor use. Each model adheres to stringent safety standards to protect against unauthorized access, ensuring the safety of personnel and assets.

In conclusion, DKS Enterprises' 1803PC, 1817, and 1815 models represent a diverse range of access control solutions tailored for various business needs. Their features focus on ease of use, advanced technology, and reliability, making them an excellent choice for organizations looking to enhance their security measures while streamlining access management.