DKS Enterprises 1817, 1803PC owner manual Programming the User Message 1815 Systems

Page 38

3.4.2 Programming the User Message – 1815 Systems

The user message, followed by the instruction message, scrolls across the screen from right to left when the system is not in use. Both the user and instruction message can be programmed to display your own message. The user message can be a maximum of 48 characters (spaces count as a character) and is entered into the system memory in three blocks. The first two blocks contain 20 characters while the third block contains 8 characters. The example below shows how the sample message was divided into three blocks. Use the blank matrix to organize your own message. Only upper case letters, numbers and spaces can be programmed from the system keypad.

Factory Default User Message = This Space is For Your User Programmable Message

NOTE: The factory default message was programmed from a PC, therefore upper and lower case letters are displayed.

Example

THANK YOU FOR VISITING OAKWOOD CONDOMINIUMS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Block 1

T

H

A

N

K

 

Y

O

U

 

F

O

R

 

V

I

S

I

T

I

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Block 2

N

G

 

O

A

K

W

O

O

D

 

C

O

N

D

O

M

I

N

I

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Block 3

U

M

S

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Block 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Block 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Block 3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

After organizing the user message in the matrix above, follow the instructions below to enter the message into the system. After each desired letter, number or space is displayed on the directory, remember to press * to enter that character. Spaces count as a character and must be entered into memory as a character. After a complete block has been entered, press * to enter the block, then start the next block.

1.Press *80 and enter the four-digit MASTER CODE _ _ _ _ (beep). The screen will display: BLOCK 1.

2.Enter the characters into block 1. Remember to press * (beep) after each character.

3.After the last character in block 1 has been entered, press * (beep) to enter the entire block. The screen will display: BLOCK 2.

4.Enter the characters into block 2. Remember to press * (beep) after each character.

5.After the last character in block 2 has been entered, press * (beep) to enter the entire block. The screen will display: BLOCK 3.

6.Enter the characters into block 3. Remember to press * (beep) after each character.

7.After the last character in block 3 has been entered, press * (beep) to enter the entire block.

8.Press * to enter all three blocks into the system memory.

9.Press 0# together to end this programming step (beeeeeep).

10.The new user message will begin to scroll across the screen.

38

Image 38
Contents 1803PC, 1815, 1817 PC Programmable Telephone Entry Systems Page Use this manual with the following models only Table of Contents Adjustments Important Notice ListingGeneral Information Features Installation Installation Guidelines ALL SystemsSurface Mount Units Surface Mount Units with Recess Box Flush Mount Units Flush Mount Rough-in Box Flush Mount Trim Ring Flush Mount Surface Mounting Kit Wall Mount Units Memory Chip Installation Postal Lock Installation Wiring 18AWG Main Terminal Description Terminal DescriptionWeigand Data Terminals Weigand Power TerminalsWeigand Terminal Description Elevator Control Terminals 4 RS-232 TerminalsRelay Wiring Typical Controlling a Single Door or GateControlling a Gate Operator and Pedestrian Gate or Door Magnetic Lock Electric Strike Gate Operator Tracker Expansion Board Control Page General Programming Information Programming with a PCProgramming from the Keypad Standard Chip MemPLUS Chip System MemorySingle or Multiple Systems Programming with a PCMaster Code Programming for Call-up Operation PC Programming TableTalk Time General ProgrammingRelay Strike Time Postal Switch Tone Open NumbersTouch-tone / Rotary-dial Rotary-dialProgramming LETTERS, Numbers and Messages Programming Letters and NumbersProgramming the User Message 1815 Systems Programming the Instruction Message 1815 Systems Programming the User Message 1817 Systems Programming the Instruction Message 1817 Systems Programming Phone Numbers and Names Programming the Directory Code Length Programming 7-digit Phone NumbersProgramming Area Codes Programming Phone Numbers with Area Code ReferenceDelete Names 1815, 1817 Systems Only Programming Names 1815, 1817 Systems OnlyDeleting Individual Phone Numbers Delete Area Codes Display Phone Numbers 1815, 1817 Systems OnlyDeleting Device Codes Programming Device CodesProgramming Device Codes Delete Four-digit Entry Codes FOUR-DIGIT Entryt CodesProgramming Four-digit Entry Codes Entry Code RangesClick Sensitivity Speaker VolumeFeedback Display Contrast 1815 OnlyRing Pin Master Code SwitchBack-light Cutoff 1817 Only Relay 2 Contact PinAdjustment Locations SEC Level Back Light Contrast Lower Contrast Upper Volume Operating Instructions Guest InstructionsResponding to a Guest Call Using an Entry CodeResident Instructions Opening from a Remote Location System AdministratorTracker Board Override Hold Open Command Relay Check Time and Date CheckConnection to a PBX Miscellaneous Operating InstructionsLine Sharing Areas with 10-digit DialingPage Maintenance Trouble ShootingSympton Possible Solutions Will be erased when this function is performed 1 RS-232 TestWeigand Test 1815, 1817 Systems Only Elevator Boards Hardware TestElevator Board / Floor Hardware Test Accessories LOG Tables Name AAC Phone Number DIR Code ENT Device SEC FL ER Level Guest Communication Granting or Denying AccessAccess Code Call Waiting

1815, 1803PC, 1817 specifications

DKS Enterprises has established itself as a leading provider of cutting-edge access control solutions, and among its notable offerings are the 1803PC, 1817, and 1815 models. These products stand out in the commercial security landscape, providing businesses with reliable and efficient entry management.

The DKS 1803PC is an advanced digital keyless entry system designed for commercial applications. Its primary feature is the easy-to-use keypad interface, which allows users to input their access codes directly. This model is equipped with a robust memory capable of storing up to 100 unique codes, making it suitable for locations with multiple users. Additionally, the 1803PC supports timed access, enabling businesses to set specific entry windows, which enhances security and access control.

The DKS 1817 model takes entry management a step further with its smart technology integration. It features Bluetooth capabilities that allow users to unlock doors via their smartphones, offering convenience and flexibility. The 1817 can be connected to various security devices, such as alarms and surveillance cameras, providing a comprehensive security ecosystem. It also includes a user-friendly mobile app that enables remote management of access permissions, ensuring that business owners can monitor and control entry points effectively from anywhere.

In contrast, the DKS 1815 model caters to businesses looking for a cost-effective yet reliable access solution. This model features a straightforward keypad interface similar to the 1803PC, but it is designed with essential functionalities to meet basic security needs. The 1815 supports up to 50 access codes and is ideal for smaller businesses or limited access areas. Its durable construction ensures longevity and requires minimal maintenance over time.

All three models employ DKS's proprietary technology that emphasizes durability and security. They are built to withstand harsh environmental conditions, making them suitable for both indoor and outdoor use. Each model adheres to stringent safety standards to protect against unauthorized access, ensuring the safety of personnel and assets.

In conclusion, DKS Enterprises' 1803PC, 1817, and 1815 models represent a diverse range of access control solutions tailored for various business needs. Their features focus on ease of use, advanced technology, and reliability, making them an excellent choice for organizations looking to enhance their security measures while streamlining access management.