DKS Enterprises 1803PC, 1815, 1817 owner manual System Administrator, Opening from a Remote Location

Page 55

5.3 SYSTEM ADMINISTRATOR

The administrator can perform the following operations from a remote location using a touch tone telephone. You must know the phone number of the system and the system master code.

5.3.1 Opening from a Remote Location

1.Call the telephone number that the entry system is installed on. The system will answer with a short tone (beep).

2.Press *16 and enter the four-digit MASTER CODE _ _ _ _ (beep).

3.Press the desired tone open number _ (beep). NOTE: Refer to 3.3.3 to determine which tone open features have been programmed, i.e. momentary open, hold open, release, hold open one hour and then release.

4.Hang up.

5.3.2 Tracker Board Override Hold Open Command

The Tracker board override command is used when tracker expansion boards are connected to the system. This command will cause ALL tracker boards connected to the telephone entry system to open or unlock the gate or door that they are controlling, and will remain in this state until commanded to return to normal operation. This feature is useful when management wants to open all gates or unlock all doors - perhaps during an emergency situation as an example.

NOTE: Hold open tone numbers must be programmed for the override command to be functional. See Section 3.3.3.

1.Call the telephone number that the entry system is installed on. The system will answer with a short tone (beep).

2.Press *16 and enter the four-digit MASTER CODE _ _ _ _ (beep).

3.Press the hold open tone number that was programmed in section 3.3.3 _ (beep).

4.Hang up.

5.To release the override hold command and return the system to normal operation, repeat steps 1 through 4. In step 3, enter the DEACTIVATE tone number in place of the HOLD tone number.

55

Image 55
Contents 1803PC, 1815, 1817 PC Programmable Telephone Entry Systems Page Use this manual with the following models only Table of Contents Adjustments Listing Important NoticeGeneral Information Features Installation Guidelines ALL Systems InstallationSurface Mount Units Surface Mount Units with Recess Box Flush Mount Units Flush Mount Rough-in Box Flush Mount Trim Ring Flush Mount Surface Mounting Kit Wall Mount Units Memory Chip Installation Postal Lock Installation Wiring 18AWG Terminal Description Main Terminal DescriptionWeigand Terminal Description Weigand Power TerminalsWeigand Data Terminals 4 RS-232 Terminals Elevator Control TerminalsControlling a Single Door or Gate Relay Wiring TypicalControlling a Gate Operator and Pedestrian Gate or Door Magnetic Lock Electric Strike Gate Operator Tracker Expansion Board Control Page Programming with a PC General Programming InformationProgramming from the Keypad System Memory Standard Chip MemPLUS ChipMaster Code Programming with a PCSingle or Multiple Systems PC Programming Table Programming for Call-up OperationRelay Strike Time General ProgrammingTalk Time Tone Open Numbers Postal SwitchRotary-dial Touch-tone / Rotary-dialProgramming Letters and Numbers Programming LETTERS, Numbers and MessagesProgramming the User Message 1815 Systems Programming the Instruction Message 1815 Systems Programming the User Message 1817 Systems Programming the Instruction Message 1817 Systems Programming Phone Numbers and Names Programming 7-digit Phone Numbers Programming the Directory Code LengthProgramming Phone Numbers with Area Code Reference Programming Area CodesDeleting Individual Phone Numbers Programming Names 1815, 1817 Systems OnlyDelete Names 1815, 1817 Systems Only Display Phone Numbers 1815, 1817 Systems Only Delete Area CodesProgramming Device Codes Programming Device CodesDeleting Device Codes Entry Code Ranges FOUR-DIGIT Entryt CodesProgramming Four-digit Entry Codes Delete Four-digit Entry CodesDisplay Contrast 1815 Only Speaker VolumeFeedback Click SensitivityRelay 2 Contact Pin Master Code SwitchBack-light Cutoff 1817 Only Ring PinAdjustment Locations SEC Level Back Light Contrast Lower Contrast Upper Volume Guest Instructions Operating InstructionsResident Instructions Using an Entry CodeResponding to a Guest Call Tracker Board Override Hold Open Command System AdministratorOpening from a Remote Location Time and Date Check Relay CheckAreas with 10-digit Dialing Miscellaneous Operating InstructionsLine Sharing Connection to a PBXPage Trouble Shooting MaintenanceSympton Possible Solutions 1 RS-232 Test Will be erased when this function is performedElevator Boards Hardware Test Weigand Test 1815, 1817 Systems OnlyElevator Board / Floor Hardware Test Accessories LOG Tables Name AAC Phone Number DIR Code ENT Device SEC FL ER Level Call Waiting Granting or Denying AccessAccess Code Guest Communication

1815, 1803PC, 1817 specifications

DKS Enterprises has established itself as a leading provider of cutting-edge access control solutions, and among its notable offerings are the 1803PC, 1817, and 1815 models. These products stand out in the commercial security landscape, providing businesses with reliable and efficient entry management.

The DKS 1803PC is an advanced digital keyless entry system designed for commercial applications. Its primary feature is the easy-to-use keypad interface, which allows users to input their access codes directly. This model is equipped with a robust memory capable of storing up to 100 unique codes, making it suitable for locations with multiple users. Additionally, the 1803PC supports timed access, enabling businesses to set specific entry windows, which enhances security and access control.

The DKS 1817 model takes entry management a step further with its smart technology integration. It features Bluetooth capabilities that allow users to unlock doors via their smartphones, offering convenience and flexibility. The 1817 can be connected to various security devices, such as alarms and surveillance cameras, providing a comprehensive security ecosystem. It also includes a user-friendly mobile app that enables remote management of access permissions, ensuring that business owners can monitor and control entry points effectively from anywhere.

In contrast, the DKS 1815 model caters to businesses looking for a cost-effective yet reliable access solution. This model features a straightforward keypad interface similar to the 1803PC, but it is designed with essential functionalities to meet basic security needs. The 1815 supports up to 50 access codes and is ideal for smaller businesses or limited access areas. Its durable construction ensures longevity and requires minimal maintenance over time.

All three models employ DKS's proprietary technology that emphasizes durability and security. They are built to withstand harsh environmental conditions, making them suitable for both indoor and outdoor use. Each model adheres to stringent safety standards to protect against unauthorized access, ensuring the safety of personnel and assets.

In conclusion, DKS Enterprises' 1803PC, 1817, and 1815 models represent a diverse range of access control solutions tailored for various business needs. Their features focus on ease of use, advanced technology, and reliability, making them an excellent choice for organizations looking to enhance their security measures while streamlining access management.