3.6 PROGRAMMING DEVICE CODES

The PC programmable telephone entry system must be equipped with a MemPLUS chip to program device codes into its memory. Device codes must be five (5) digits in length and are typically card and transmitter codes. Each device code that you enter is assigned to the directory code that you select. Up to 25 device numbers can be entered under a single directory code, up to a maximum of 8,000 for the system. You cannot duplicate device codes.

3.6.1 Programming Device Codes

This program sequence enters device (card, transmitter, digital) codes into the system memory.

1.Press *70 and enter the four-digit MASTER CODE _ _ _ _ (beep).

2.Enter the directory code that the device code is to be assigned to (1, 2, 3 or 4 digits depending on what was programmed in 3.5.1) then press * (beep).

3.Enter the five-digit device code _ _ _ _ _ then press * (beep).

4.Repeat steps 2 and 3 to enter additional device codes.

5.Press 0# TOGETHER to end this programming step (beeeeeep).

3.6.2 Deleting Device Codes

This program sequence deletes individual device codes.

1.Press *71 and enter the four-digit MASTER CODE _ _ _ _ (beep).

2.Enter the directory code (1, 2, 3 or 4 digits depending on what was programmed in 3.5.1) then press * (beep).

3.Enter the five-digit device code _ _ _ _ _ then press * (beep).

4.Repeat steps 2 and 3 to delete additional device codes.

5.Press 0# TOGETHER to end this programming step (beeeeeep).

47

Image 47
Contents 1803PC, 1815, 1817 PC Programmable Telephone Entry Systems Page Use this manual with the following models only Table of Contents Adjustments Listing Important NoticeGeneral Information Features Installation Guidelines ALL Systems InstallationSurface Mount Units Surface Mount Units with Recess Box Flush Mount Units Flush Mount Rough-in Box Flush Mount Trim Ring Flush Mount Surface Mounting Kit Wall Mount Units Memory Chip Installation Postal Lock Installation Wiring 18AWG Terminal Description Main Terminal DescriptionWeigand Data Terminals Weigand Power TerminalsWeigand Terminal Description 4 RS-232 Terminals Elevator Control TerminalsControlling a Single Door or Gate Relay Wiring TypicalControlling a Gate Operator and Pedestrian Gate or Door Magnetic Lock Electric Strike Gate Operator Tracker Expansion Board Control Page Programming with a PC General Programming InformationProgramming from the Keypad System Memory Standard Chip MemPLUS ChipSingle or Multiple Systems Programming with a PCMaster Code PC Programming Table Programming for Call-up OperationTalk Time General ProgrammingRelay Strike Time Tone Open Numbers Postal SwitchRotary-dial Touch-tone / Rotary-dialProgramming Letters and Numbers Programming LETTERS, Numbers and MessagesProgramming the User Message 1815 Systems Programming the Instruction Message 1815 Systems Programming the User Message 1817 Systems Programming the Instruction Message 1817 Systems Programming Phone Numbers and Names Programming 7-digit Phone Numbers Programming the Directory Code LengthProgramming Phone Numbers with Area Code Reference Programming Area CodesDelete Names 1815, 1817 Systems Only Programming Names 1815, 1817 Systems OnlyDeleting Individual Phone Numbers Display Phone Numbers 1815, 1817 Systems Only Delete Area CodesDeleting Device Codes Programming Device CodesProgramming Device Codes Entry Code Ranges FOUR-DIGIT Entryt CodesProgramming Four-digit Entry Codes Delete Four-digit Entry CodesDisplay Contrast 1815 Only Speaker VolumeFeedback Click SensitivityRelay 2 Contact Pin Master Code SwitchBack-light Cutoff 1817 Only Ring PinAdjustment Locations SEC Level Back Light Contrast Lower Contrast Upper Volume Guest Instructions Operating InstructionsResponding to a Guest Call Using an Entry CodeResident Instructions Opening from a Remote Location System AdministratorTracker Board Override Hold Open Command Time and Date Check Relay CheckAreas with 10-digit Dialing Miscellaneous Operating InstructionsLine Sharing Connection to a PBXPage Trouble Shooting MaintenanceSympton Possible Solutions 1 RS-232 Test Will be erased when this function is performedElevator Boards Hardware Test Weigand Test 1815, 1817 Systems OnlyElevator Board / Floor Hardware Test Accessories LOG Tables Name AAC Phone Number DIR Code ENT Device SEC FL ER Level Call Waiting Granting or Denying AccessAccess Code Guest Communication

1815, 1803PC, 1817 specifications

DKS Enterprises has established itself as a leading provider of cutting-edge access control solutions, and among its notable offerings are the 1803PC, 1817, and 1815 models. These products stand out in the commercial security landscape, providing businesses with reliable and efficient entry management.

The DKS 1803PC is an advanced digital keyless entry system designed for commercial applications. Its primary feature is the easy-to-use keypad interface, which allows users to input their access codes directly. This model is equipped with a robust memory capable of storing up to 100 unique codes, making it suitable for locations with multiple users. Additionally, the 1803PC supports timed access, enabling businesses to set specific entry windows, which enhances security and access control.

The DKS 1817 model takes entry management a step further with its smart technology integration. It features Bluetooth capabilities that allow users to unlock doors via their smartphones, offering convenience and flexibility. The 1817 can be connected to various security devices, such as alarms and surveillance cameras, providing a comprehensive security ecosystem. It also includes a user-friendly mobile app that enables remote management of access permissions, ensuring that business owners can monitor and control entry points effectively from anywhere.

In contrast, the DKS 1815 model caters to businesses looking for a cost-effective yet reliable access solution. This model features a straightforward keypad interface similar to the 1803PC, but it is designed with essential functionalities to meet basic security needs. The 1815 supports up to 50 access codes and is ideal for smaller businesses or limited access areas. Its durable construction ensures longevity and requires minimal maintenance over time.

All three models employ DKS's proprietary technology that emphasizes durability and security. They are built to withstand harsh environmental conditions, making them suitable for both indoor and outdoor use. Each model adheres to stringent safety standards to protect against unauthorized access, ensuring the safety of personnel and assets.

In conclusion, DKS Enterprises' 1803PC, 1817, and 1815 models represent a diverse range of access control solutions tailored for various business needs. Their features focus on ease of use, advanced technology, and reliability, making them an excellent choice for organizations looking to enhance their security measures while streamlining access management.