Surface Trim Ring

Use to recess a surface mount unit into a wall or column. P/N 1803-150.

Flush Kit

Use to install flush style units into a wall or column. Kit includes rough in

 

back box and trim ring. P/N 1814-165 comes with stainless steel trim

 

ring. P/N 1814-166 comes with gold plated trim ring.

Flush Ring

Use to surface mount a flush style unit. P/N 1814-152.

Stainless Steel Case

Replaces the black steel surface mount case with a stainless steel case.

 

P/N 1810-102.

Surge Suppressers

High voltage (115 V) suppresser. P/N 1878-076. Phone line

 

suppresser. P/N 1878-077. Low voltage (28 V) suppresser. P/N 1878-

 

078.

Mounting Post

Heavy-duty goose-neck mounting post with mounting plate. P/N 1200-

 

048. Heavy-duty goose-neck mounting post with concrete base plate for

 

pad mounting. P/N 1200-047.

Telephone Test Set

Includes clips, cord and carrying case. P/N 1800-050.

Battery

12 volt .8 amp hour gel cell provides stand by power during power

 

interruptions. P/N 1801-008.

Tracker Boards

Tracker expansion boards (P/N 2351-010) allow the 1815 / 1817 system

 

to operate up to sixteen individual doors or gates, provides door ajar and

 

forced entry alarms, and can activate local and building alarm systems.

 

Also allows DoorKing gate operators to report gate operator data and

 

activity to the entry system.

RS-232 Cable

RS-232 cable with DB-9 connector on one end and wires on the other

 

end. Use this cable to program the entry system from a PC using RS-

 

232 communications instead of the modem. P/N 1818-040.

Elevator Board

Elevator control boards (P/N 2348-010) provide control of up to four

 

elevators, with each elevator having a maximum of 64 floors.

64

Image 64
Contents 1803PC, 1815, 1817 PC Programmable Telephone Entry Systems Page Use this manual with the following models only Table of Contents Adjustments Important Notice ListingGeneral Information Features Installation Installation Guidelines ALL SystemsSurface Mount Units Surface Mount Units with Recess Box Flush Mount Units Flush Mount Rough-in Box Flush Mount Trim Ring Flush Mount Surface Mounting Kit Wall Mount Units Memory Chip Installation Postal Lock Installation Wiring 18AWG Main Terminal Description Terminal DescriptionWeigand Terminal Description Weigand Power TerminalsWeigand Data Terminals Elevator Control Terminals 4 RS-232 TerminalsRelay Wiring Typical Controlling a Single Door or GateControlling a Gate Operator and Pedestrian Gate or Door Magnetic Lock Electric Strike Gate Operator Tracker Expansion Board Control Page General Programming Information Programming with a PCProgramming from the Keypad Standard Chip MemPLUS Chip System MemoryMaster Code Programming with a PCSingle or Multiple Systems Programming for Call-up Operation PC Programming TableRelay Strike Time General ProgrammingTalk Time Postal Switch Tone Open NumbersTouch-tone / Rotary-dial Rotary-dialProgramming LETTERS, Numbers and Messages Programming Letters and NumbersProgramming the User Message 1815 Systems Programming the Instruction Message 1815 Systems Programming the User Message 1817 Systems Programming the Instruction Message 1817 Systems Programming Phone Numbers and Names Programming the Directory Code Length Programming 7-digit Phone NumbersProgramming Area Codes Programming Phone Numbers with Area Code ReferenceDeleting Individual Phone Numbers Programming Names 1815, 1817 Systems OnlyDelete Names 1815, 1817 Systems Only Delete Area Codes Display Phone Numbers 1815, 1817 Systems OnlyProgramming Device Codes Programming Device CodesDeleting Device Codes FOUR-DIGIT Entryt Codes Programming Four-digit Entry CodesDelete Four-digit Entry Codes Entry Code RangesSpeaker Volume FeedbackClick Sensitivity Display Contrast 1815 OnlyMaster Code Switch Back-light Cutoff 1817 OnlyRing Pin Relay 2 Contact PinAdjustment Locations SEC Level Back Light Contrast Lower Contrast Upper Volume Operating Instructions Guest InstructionsResident Instructions Using an Entry CodeResponding to a Guest Call Tracker Board Override Hold Open Command System AdministratorOpening from a Remote Location Relay Check Time and Date CheckMiscellaneous Operating Instructions Line SharingConnection to a PBX Areas with 10-digit DialingPage Maintenance Trouble ShootingSympton Possible Solutions Will be erased when this function is performed 1 RS-232 TestWeigand Test 1815, 1817 Systems Only Elevator Boards Hardware TestElevator Board / Floor Hardware Test Accessories LOG Tables Name AAC Phone Number DIR Code ENT Device SEC FL ER Level Granting or Denying Access Access CodeGuest Communication Call Waiting

1815, 1803PC, 1817 specifications

DKS Enterprises has established itself as a leading provider of cutting-edge access control solutions, and among its notable offerings are the 1803PC, 1817, and 1815 models. These products stand out in the commercial security landscape, providing businesses with reliable and efficient entry management.

The DKS 1803PC is an advanced digital keyless entry system designed for commercial applications. Its primary feature is the easy-to-use keypad interface, which allows users to input their access codes directly. This model is equipped with a robust memory capable of storing up to 100 unique codes, making it suitable for locations with multiple users. Additionally, the 1803PC supports timed access, enabling businesses to set specific entry windows, which enhances security and access control.

The DKS 1817 model takes entry management a step further with its smart technology integration. It features Bluetooth capabilities that allow users to unlock doors via their smartphones, offering convenience and flexibility. The 1817 can be connected to various security devices, such as alarms and surveillance cameras, providing a comprehensive security ecosystem. It also includes a user-friendly mobile app that enables remote management of access permissions, ensuring that business owners can monitor and control entry points effectively from anywhere.

In contrast, the DKS 1815 model caters to businesses looking for a cost-effective yet reliable access solution. This model features a straightforward keypad interface similar to the 1803PC, but it is designed with essential functionalities to meet basic security needs. The 1815 supports up to 50 access codes and is ideal for smaller businesses or limited access areas. Its durable construction ensures longevity and requires minimal maintenance over time.

All three models employ DKS's proprietary technology that emphasizes durability and security. They are built to withstand harsh environmental conditions, making them suitable for both indoor and outdoor use. Each model adheres to stringent safety standards to protect against unauthorized access, ensuring the safety of personnel and assets.

In conclusion, DKS Enterprises' 1803PC, 1817, and 1815 models represent a diverse range of access control solutions tailored for various business needs. Their features focus on ease of use, advanced technology, and reliability, making them an excellent choice for organizations looking to enhance their security measures while streamlining access management.