DKS Enterprises 1815, 1803PC, 1817 Programming for Call-up Operation, PC Programming Table

Page 33

3.2.3 Programming for Call-up Operation

This feature is only used when the telephone entry system is interfaced with a DoorKing 1816 Telephone Intercom system under certain special applications. The factory setting for this feature is OFF. Do not change this feature to ON. Refer to the 1816 Installation Manual, and check with your DoorKing representative on the special applications that this feature is used for.

Factory Setting = OFF

1.Press *78 and enter the four-digit MASTER CODE _ _ _ _ (beep).

2.Enter 0* (beep) to turn the call up feature OFF. Enter 1* (beep) to turn call up ON.

3.Press 0# TOGETHER to end this programming step (beeeeeep).

3.2.4 PC Programming Table

The information in the chart will be required when you program the PC programmable telephone entry system from your PC. The chart is provided for you to record the information that has been programmed in the preceding steps.

Control Board

Master Code

Memory Size

Memory Chip

Single / Multiple

Series

(enter number)

(circle one)

(circle one)

(circle one)

 

 

 

 

 

40E

 

25 75 125 250

MemPLUS

SINGLE

(enhanced)

 

500 1000 2000

 

 

 

 

3000

STANDARD

MULTIPLE

 

 

 

 

 

STOP!!

If the telephone entry system is to be programmed from a PC, no other programming is required at the system itself. Complete the chart in section 3.2.4 as this information will be required when programming the unit from your computer. Refer to the Remote Account Manager for Windows software manual for additional programming information. Continue with the remaining sections in this chapter if the telephone entry system will be programmed by any other method. If the factory setting matches your need, there is no reason to reprogram that section.

Remember that relay hold open time zones, security levels, and elevator control functions can only be programmed from the Remote Account Manager software. If any of these features are being used, do not proceed with any other programming steps in this manual.

33

Image 33
Contents 1803PC, 1815, 1817 PC Programmable Telephone Entry Systems Page Use this manual with the following models only Table of Contents Adjustments Listing Important NoticeGeneral Information Features Installation Guidelines ALL Systems InstallationSurface Mount Units Surface Mount Units with Recess Box Flush Mount Units Flush Mount Rough-in Box Flush Mount Trim Ring Flush Mount Surface Mounting Kit Wall Mount Units Memory Chip Installation Postal Lock Installation Wiring 18AWG Terminal Description Main Terminal DescriptionWeigand Power Terminals Weigand Terminal DescriptionWeigand Data Terminals 4 RS-232 Terminals Elevator Control TerminalsControlling a Single Door or Gate Relay Wiring TypicalControlling a Gate Operator and Pedestrian Gate or Door Magnetic Lock Electric Strike Gate Operator Tracker Expansion Board Control Page Programming with a PC General Programming InformationProgramming from the Keypad System Memory Standard Chip MemPLUS ChipProgramming with a PC Master CodeSingle or Multiple Systems PC Programming Table Programming for Call-up OperationGeneral Programming Relay Strike TimeTalk Time Tone Open Numbers Postal SwitchRotary-dial Touch-tone / Rotary-dialProgramming Letters and Numbers Programming LETTERS, Numbers and MessagesProgramming the User Message 1815 Systems Programming the Instruction Message 1815 Systems Programming the User Message 1817 Systems Programming the Instruction Message 1817 Systems Programming Phone Numbers and Names Programming 7-digit Phone Numbers Programming the Directory Code LengthProgramming Phone Numbers with Area Code Reference Programming Area CodesProgramming Names 1815, 1817 Systems Only Deleting Individual Phone NumbersDelete Names 1815, 1817 Systems Only Display Phone Numbers 1815, 1817 Systems Only Delete Area CodesProgramming Device Codes Programming Device CodesDeleting Device Codes Programming Four-digit Entry Codes FOUR-DIGIT Entryt CodesDelete Four-digit Entry Codes Entry Code RangesFeedback Speaker VolumeClick Sensitivity Display Contrast 1815 OnlyBack-light Cutoff 1817 Only Master Code SwitchRing Pin Relay 2 Contact PinAdjustment Locations SEC Level Back Light Contrast Lower Contrast Upper Volume Guest Instructions Operating InstructionsUsing an Entry Code Resident InstructionsResponding to a Guest Call System Administrator Tracker Board Override Hold Open CommandOpening from a Remote Location Time and Date Check Relay CheckLine Sharing Miscellaneous Operating InstructionsConnection to a PBX Areas with 10-digit DialingPage Trouble Shooting MaintenanceSympton Possible Solutions 1 RS-232 Test Will be erased when this function is performedElevator Boards Hardware Test Weigand Test 1815, 1817 Systems OnlyElevator Board / Floor Hardware Test Accessories LOG Tables Name AAC Phone Number DIR Code ENT Device SEC FL ER Level Access Code Granting or Denying AccessGuest Communication Call Waiting

1815, 1803PC, 1817 specifications

DKS Enterprises has established itself as a leading provider of cutting-edge access control solutions, and among its notable offerings are the 1803PC, 1817, and 1815 models. These products stand out in the commercial security landscape, providing businesses with reliable and efficient entry management.

The DKS 1803PC is an advanced digital keyless entry system designed for commercial applications. Its primary feature is the easy-to-use keypad interface, which allows users to input their access codes directly. This model is equipped with a robust memory capable of storing up to 100 unique codes, making it suitable for locations with multiple users. Additionally, the 1803PC supports timed access, enabling businesses to set specific entry windows, which enhances security and access control.

The DKS 1817 model takes entry management a step further with its smart technology integration. It features Bluetooth capabilities that allow users to unlock doors via their smartphones, offering convenience and flexibility. The 1817 can be connected to various security devices, such as alarms and surveillance cameras, providing a comprehensive security ecosystem. It also includes a user-friendly mobile app that enables remote management of access permissions, ensuring that business owners can monitor and control entry points effectively from anywhere.

In contrast, the DKS 1815 model caters to businesses looking for a cost-effective yet reliable access solution. This model features a straightforward keypad interface similar to the 1803PC, but it is designed with essential functionalities to meet basic security needs. The 1815 supports up to 50 access codes and is ideal for smaller businesses or limited access areas. Its durable construction ensures longevity and requires minimal maintenance over time.

All three models employ DKS's proprietary technology that emphasizes durability and security. They are built to withstand harsh environmental conditions, making them suitable for both indoor and outdoor use. Each model adheres to stringent safety standards to protect against unauthorized access, ensuring the safety of personnel and assets.

In conclusion, DKS Enterprises' 1803PC, 1817, and 1815 models represent a diverse range of access control solutions tailored for various business needs. Their features focus on ease of use, advanced technology, and reliability, making them an excellent choice for organizations looking to enhance their security measures while streamlining access management.