5. Cable installation

5-1 Cable selection

Use 2-conductor telephone or interphone cables for connection from the exchange to the station.

Be sure to use a multi-pair twisted cable such as an indoor cable and CCP-(A)P cable when the connection is

made via the external terminal board.

Select appropriate cables according to the following table that shows the relationship between cable diameter and transmission distance.

Core diameter

Service distance

0.5 mm

1.0km

(1.5km)

0.65mm

1.5km

(2.5km)

0.9 mm

2.5km

(3.5km)

Note

The figure in a parenthesis is the maximum cable length and shown at its left is the normal service distance. The

system supplied from the factory is pre-wired for the

normal service distance. To obtain the maximum cable length, replace the corresponding resistor R31, R39,

R51 or R59 (390k ohms) on the LM unit corresponding to

the line with that of 680k ohms. (See paragraph 6-10.)

5-2 Points to remember

The multi-pair cable used for wiring of the EXES-2000

 

system must not be jointly used as a power cable or

Not allowed

data transmitting cable for facsimile, etc.

 

Do not connect an unused cable to the exchange.

 

Do not connect an unused cable to a connection

 

cable between the exchange and the station.

Exchange

When utilizing multi-core cables already in use for

Station

wiring, confirm they are twisted paired cables. Unless

Not allowed

they are twisted cables, they may not be used due to

 

interference between lines.

 

5-3 Wiring examples

Multi-pair cable

Indoor

ExchangeterminalStations board

2-conductor interphone cables

Stations

– 9 –

Image 10
Contents EX-200 Contents Before Reading this Hand BookPower Description and featuresExamples of system configuration BGM distribution up to 3 channelsCentral control unit CC-20 Remote control unit RC-20Power transformer unit PU-200 Line modem unit LM-20Installation of equipment Installing and adjusting proceduresSelection of the place to install Installation of the exchange DimensionsInstalling FC-210 extension cabinet Installation of PU-200 power supply unit Wall Base Case For case Switch boxFor plate Exchange Cable installationR51 or R59 390k ohms on the LM unit corresponding to Indoor ExchangeterminalStations boardEstablishment of the LM unit number Connection of equipmentAddition of LM unit Mounting LM unit For the system with up to 16 stationsLM unit wiring Mounting option unit Bl unit Connection of station plug to jackMounting other option units than the Bl unit Bl unit connection Alarm tone, etcBGM equipment Door locking RC unit connectionPTT.C PTT control Radio Station EquipmentMaximum contact capacity 125 VA 125V AC or 30V DC 1A PC unit connectionSerial data output Tl unit connection SM unit number setting Service distance Connection for speaker stationConnection of power source Voltage selectorProcedures of initial set-up and No programming Initial set-up and programming No programmingTransfer PA paging & power remote/3-channel general purpose controlDoor remote control 2 circuits Secretary transfer Hurry upRegistration of each function EX-610/620/630Highest Executive Priority Will be heard Times Be sure to depress Key Steadily Continuous Calling ToneTouch Stations Allowed Access to Paging Stations Allowed Access to Emergency Call Allowed Station NoHandset Station Registration Will be heardHave this Function Times Be sure to depress Key SteadilyStations Allowed Access to Speech Message AllowedDoor Substation Registration Secretary Transfer Release finished?MASTER/SUB Relationship Registration of Stations to Refuse ALL-CALL Paging Registration of Station to Refuse Zone 1 Paging Dial Will be heard TimesRegistration of Stations to Refuse Zone 2 Paging Repeat twice Registration of next allowed stationRegistration of Stations to Refuse Zone 3 Paging Step Method of Speech test Hands-free conversation Performance TestSpeech and Function Tests Speech Test Handset conversationTrouble-shooting at the time of installation Noise is heard from the station Replace stationFunction Table for Stations Door SubstationStation Data Table Station Data Table3 0 6 1 3 5 6 C